S. Vernick
Research Subjects
S. Vernick has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
A. Freeman
Department of Molecular Microbiology and Biotechnology, Tel-Aviv University, Tel-Aviv, 69978, Israel
1 shared publicationA. Vilkin
Department of Gastroenterology, Rabin Medical Center, Petach Tikva, 49100, Israel
1 shared publicationJ. Rishpon
Department of Molecular Microbiology and Biotechnology, Tel-Aviv University, Tel-Aviv, 69978, Israel
1 shared publicationY. Niv
Department of Gastroenterology, Rabin Medical Center, Petach Tikva, 49100, Israel
1 shared publicationY. Shacham-Diamand
Department of Physical Electronics and
1 shared publication
Latest Publications
- 1 January 2011
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 158 (1) , P1-P4
Electrochemical Biosensing for Direct Biopsy Slices Screening for Colorectal Cancer Detection
A new electrochemical assay performed directly on fresh tumor biopsies is described. Substrate mediated electrochemical biosensor was used to screen biopsy slices for colon cancer via electrochemical determination of enzymatic activity to distinguish between cancerous and normal epithelial tissues. The screen was based on the downregulation of the enzyme alkaline phosphatase (ALP) in intestine epithelial cancerous cells. The ALP activity recorded from fresh biopsy samples removed from colon tumors induced in mice was compared to that from samples collected simultaneously from the small and large healthy intestines of same mice. Samples were suspended in a specially designed multichamber electrochemical sensor. Upon the addition of the substrate p-aminophenol phosphate yielding p-aminophenol resulting from the enzymatic reaction, a voltage was applied between a working and a reference Ag∕AgClAg∕AgCl microelectrode and current was recorded. Significant differences in current signal were observed for biopsies removed from tumors compared with samples removed from healthy tissue. Reproducibility was demonstrated. The new technology allows a direct assay carried out on small volume slices from fresh biopsies without the need for pretreatment and labor intensive preparative steps. The new assay offers rapid and straightforward detection providing results obtained within minutes of biopsy removal.
- 1 January 2011
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 158 (1) , P1-P4
Electrochemical Biosensing for Direct Biopsy Slices Screening for Colorectal Cancer Detection
A new electrochemical assay performed directly on fresh tumor biopsies is described. Substrate mediated electrochemical biosensor was used to screen biopsy slices for colon cancer via electrochemical determination of enzymatic activity to distinguish between cancerous and normal epithelial tissues. The screen was based on the downregulation of the enzyme alkaline phosphatase (ALP) in intestine epithelial cancerous cells. The ALP activity recorded from fresh biopsy samples removed from colon tumors induced in mice was compared to that from samples collected simultaneously from the small and large healthy intestines of same mice. Samples were suspended in a specially designed multichamber electrochemical sensor. Upon the addition of the substrate p-aminophenol phosphate yielding p-aminophenol resulting from the enzymatic reaction, a voltage was applied between a working and a reference Ag∕AgClAg∕AgCl microelectrode and current was recorded. Significant differences in current signal were observed for biopsies removed from tumors compared with samples removed from healthy tissue. Reproducibility was demonstrated. The new technology allows a direct assay carried out on small volume slices from fresh biopsies without the need for pretreatment and labor intensive preparative steps. The new assay offers rapid and straightforward detection providing results obtained within minutes of biopsy removal.