Peilin Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Peilin Yang has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Matthias Pursch
Dow, Analytical Science
4 shared publications- Jim Luong
Dow Chemical Canada ULC, Alberta, Canada
3 shared publications Wei Gao
Dow Chem Co USA, Analyt Sci, Collegeville, PA 19426 USA
3 shared publicationsRonda Gras
Dow Chemical Canada ULC, Highway 15, Fort Saskatchewan, Alberta T8L 2P4, Canada; Australian Centre for Research on Separation Science (ACROSS), University of Tasmania, Private Bag 75 Hobart 7001 Australia
2 shared publicationsTerry McCabe
The Dow Chemical Company, Analytical Technologies, Midland, MI, USA
2 shared publicationsYujuan Hua
Dow Chemical Canada ULC, Highway 15, Fort Saskatchewan, Alberta T8L 2P4, Canada
2 shared publications
Latest Publications
- 15 February 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1772, 466810
Comprehensive two-dimensional liquid chromatography with non-aqueous hydrophilic interaction conditions enables resolution of isomers of EO/PO surfactants
- 15 February 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1772, 466810
Comprehensive two-dimensional liquid chromatography with non-aqueous hydrophilic interaction conditions enables resolution of isomers of EO/PO surfactants
- Open Access
- 29 October 2025
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 5 (6) , 780-789
An Advanced Gas Chromatography–Mass Spectrometry Workflow for High-Confidence Non-Targeted Screening of Non-Intentionally Added Substances in Recycled Plastics
As circularity grows in the global economy, recycling has become more relevant in the plastic materials industry. Recycled plastics, sourced from various origins, can contain numerous non-intentionally added substances such as organic contaminants, polymer degradation products, and consumer residues. The confident identification of contaminants has become an important step in the quality assessment of the recycled material and the evaluation of cleaning processes. However, traditional one-dimensional gas chromatography often encounters challenges in reporting accurate results for these complex samples. In this work, we combine a cryogen-free comprehensive two-dimensional gas chromatographic separation coupled with high-resolution mass spectrometry and a new confidence-level-based data reporting workflow to achieve more rigorous and higher-confidence identification of nontargeted species in recycled plastics. We propose four confidence levels, and seven confidence descriptor classifications based on mass spectral matching, retention index matching, and mass accuracy from high-resolution mass spectral data. The workflow was applied to postconsumer recycled plastics before and after the cleaning process. Higher than 70% of identifications are made with medium-to-high confidence. About 50% more peaks are separated and identified by the workflow compared to traditional one-dimensional separation without significant increase in data collection and analysis time. The workflow was validated by recycled plastics spiked with 26 known compounds of environmental relevance covering a broad range of chemical structures.
- 29 October 2025
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 5 (6) , 780-789
Open AccessAn Advanced Gas Chromatography–Mass Spectrometry Workflow for High-Confidence Non-Targeted Screening of Non-Intentionally Added Substances in Recycled Plastics
As circularity grows in the global economy, recycling has become more relevant in the plastic materials industry. Recycled plastics, sourced from various origins, can contain numerous non-intentionally added substances such as organic contaminants, polymer degradation products, and consumer residues. The confident identification of contaminants has become an important step in the quality assessment of the recycled material and the evaluation of cleaning processes. However, traditional one-dimensional gas chromatography often encounters challenges in reporting accurate results for these complex samples. In this work, we combine a cryogen-free comprehensive two-dimensional gas chromatographic separation coupled with high-resolution mass spectrometry and a new confidence-level-based data reporting workflow to achieve more rigorous and higher-confidence identification of nontargeted species in recycled plastics. We propose four confidence levels, and seven confidence descriptor classifications based on mass spectral matching, retention index matching, and mass accuracy from high-resolution mass spectral data. The workflow was applied to postconsumer recycled plastics before and after the cleaning process. Higher than 70% of identifications are made with medium-to-high confidence. About 50% more peaks are separated and identified by the workflow compared to traditional one-dimensional separation without significant increase in data collection and analysis time. The workflow was validated by recycled plastics spiked with 26 known compounds of environmental relevance covering a broad range of chemical structures.
- 5 March 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1694, 463909
Identification and quantification of polymeric impurity in block copolymer by one-dimensional and two-dimensional liquid chromatography coupled to high-resolution mass spectrometry and evaporative light scattering detector
- 5 March 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1694, 463909
Identification and quantification of polymeric impurity in block copolymer by one-dimensional and two-dimensional liquid chromatography coupled to high-resolution mass spectrometry and evaporative light scattering detector
- Open Access
- 1 April 2022
- Published by Multimedia Pharma Sciences, LLC in LCGC North America
- Vol. 40 (4) , 186-189
Gaining New Insights in Advanced Polymeric Materials Using Comprehensive Two-Dimensional Liquid Chromatography
Two-dimensional liquid chromatography (2D-LC) offers new insights into modern polymeric materials such as biodegradable polymers, polymers made from renewable feedstock, and complex formulated systems. Advances in instrumentation and the development of new modulation techniques enable more combinations of different separation modes. Hyphenation with universal and information-rich detectors further enhances the versatility and flexibility of the analytical strategy. Detailed characterization of copolymer composition heterogeneity and identification of polymeric ingredients in complex consumer products are key highlights of new applications.
- 1 April 2022
- Published by Multimedia Pharma Sciences, LLC in LCGC North America
- Vol. 40 (4) , 186-189
Open AccessGaining New Insights in Advanced Polymeric Materials Using Comprehensive Two-Dimensional Liquid Chromatography
Two-dimensional liquid chromatography (2D-LC) offers new insights into modern polymeric materials such as biodegradable polymers, polymers made from renewable feedstock, and complex formulated systems. Advances in instrumentation and the development of new modulation techniques enable more combinations of different separation modes. Hyphenation with universal and information-rich detectors further enhances the versatility and flexibility of the analytical strategy. Detailed characterization of copolymer composition heterogeneity and identification of polymeric ingredients in complex consumer products are key highlights of new applications.
- 1 January 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1609, 460460
Post-column reaction with a 3D-printed two-stage microreactor and flame ionization detection for carbon compound independent response in fast gas chromatography
- 1 January 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1609, 460460
Post-column reaction with a 3D-printed two-stage microreactor and flame ionization detection for carbon compound independent response in fast gas chromatography
- 18 July 2019
- Published by Wiley in Journal of Separation Science
- Vol. 42 (17) , 2805-2815
Two‐dimensional liquid chromatography with active solvent modulation for studying monomer incorporation in copolymer dispersants
A pseudo‐comprehensive two‐dimensional liquid chromatography approach with size exclusion chromatography in the first dimension and gradient reversed‐phase liquid chromatography in the second dimension was successfully developed for the characterization of vinyl acetate/acrylic acid copolymers and vinyl acetate/itaconic acid/acrylic acid terpolymers. Active solvent modulation was exploited to prevent the polymer breakthrough in the second dimension separation caused by the strong solvent used in the first dimension. The conditions of the active solvent modulation valve were optimized to achieve sufficient on‐line dilution and to completely prevent polymer breakthrough without adding excessive time to the modulation cycle. Using this approach, copolymers made with different monomer ratios and processes were studied. Heterogeneous composition distribution due to insufficient monomer incorporation was detected in some of the copolymer samples. We demonstrated that with active solvent modulation, the two‐dimensional liquid chromatography approach is no longer limited to water‐soluble polymers and can be used for a broader range of polymers and copolymers.
- 18 July 2019
- Published by Wiley in Journal of Separation Science
- Vol. 42 (17) , 2805-2815
Two‐dimensional liquid chromatography with active solvent modulation for studying monomer incorporation in copolymer dispersants
A pseudo‐comprehensive two‐dimensional liquid chromatography approach with size exclusion chromatography in the first dimension and gradient reversed‐phase liquid chromatography in the second dimension was successfully developed for the characterization of vinyl acetate/acrylic acid copolymers and vinyl acetate/itaconic acid/acrylic acid terpolymers. Active solvent modulation was exploited to prevent the polymer breakthrough in the second dimension separation caused by the strong solvent used in the first dimension. The conditions of the active solvent modulation valve were optimized to achieve sufficient on‐line dilution and to completely prevent polymer breakthrough without adding excessive time to the modulation cycle. Using this approach, copolymers made with different monomer ratios and processes were studied. Heterogeneous composition distribution due to insufficient monomer incorporation was detected in some of the copolymer samples. We demonstrated that with active solvent modulation, the two‐dimensional liquid chromatography approach is no longer limited to water‐soluble polymers and can be used for a broader range of polymers and copolymers.
- 27 June 2019
- Published by Wiley in Journal of Separation Science
- Vol. 42 (17) , 2826-2834
Metal 3D‐printed catalytic jet and flame ionization detection for in situ trace carbon oxides analysis by gas chromatography
A gas chromatographic approach for the determination and quantification of trace levels of carbon oxides in gas phase matrices for in situ or near‐line/at‐line analysis has been successfully developed. Catalytic conversion of the target compounds to methane via the methanation process was conducted inside a metal 3D‐printed jet that also acted as a hydrogen burner for the flame ionization detector. Modifications made to a field transportable gas chromatograph enabled the leveraging of advantaged microfluidic‐enhanced chromatography capability for improved chromatographic performance and serviceability. The compatibility with adsorption chromatography technology was demonstrated with in‐house constructed columns. Sustained reliable conversion efficiencies of greater than 99% with respectable peak symmetries were attained at 400°C. Quantification of carbon monoxide and carbon dioxide at a parts‐per‐million level over a range from 0.2 ppm to 5% v/v for both compounds with a respectable precision of less than 3% relative standard deviation for peak area (n = 10) and a detection limit of 0.1 ppm v/v was achieved. Linearity with correlation coefficients of R2 greater than 0.9995 and measured recoveries of >99% for spike tests were achieved. The 3D‐printed steel jet was found to be reliable and resilient against potential contamination from the matrices owing to the in situ backflushing capability.
- 27 June 2019
- Published by Wiley in Journal of Separation Science
- Vol. 42 (17) , 2826-2834
Metal 3D‐printed catalytic jet and flame ionization detection for in situ trace carbon oxides analysis by gas chromatography
A gas chromatographic approach for the determination and quantification of trace levels of carbon oxides in gas phase matrices for in situ or near‐line/at‐line analysis has been successfully developed. Catalytic conversion of the target compounds to methane via the methanation process was conducted inside a metal 3D‐printed jet that also acted as a hydrogen burner for the flame ionization detector. Modifications made to a field transportable gas chromatograph enabled the leveraging of advantaged microfluidic‐enhanced chromatography capability for improved chromatographic performance and serviceability. The compatibility with adsorption chromatography technology was demonstrated with in‐house constructed columns. Sustained reliable conversion efficiencies of greater than 99% with respectable peak symmetries were attained at 400°C. Quantification of carbon monoxide and carbon dioxide at a parts‐per‐million level over a range from 0.2 ppm to 5% v/v for both compounds with a respectable precision of less than 3% relative standard deviation for peak area (n = 10) and a detection limit of 0.1 ppm v/v was achieved. Linearity with correlation coefficients of R2 greater than 0.9995 and measured recoveries of >99% for spike tests were achieved. The 3D‐printed steel jet was found to be reliable and resilient against potential contamination from the matrices owing to the in situ backflushing capability.
- 1 September 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1566, 111-117
Separation and identification of polymeric dispersants in detergents by two-dimensional liquid chromatography
- 1 September 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1566, 111-117
Separation and identification of polymeric dispersants in detergents by two-dimensional liquid chromatography
- 1 July 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1560, 55-62
Analysis of hydrophobically modified ethylene oxide urethane rheology modifiers by comprehensive two dimensional liquid chromatography
- 1 July 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1560, 55-62
Analysis of hydrophobically modified ethylene oxide urethane rheology modifiers by comprehensive two dimensional liquid chromatography
- 23 April 2015
- Published by Wiley in Journal of Separation Science
- Vol. 38 (13) , 2253-2259
Hydrophilic interaction liquid chromatography for the separation of acidic agricultural compounds
Organic acids with very low pKa require extremely low pH conditions to achieve adequate retention in reversed‐phase liquid chromatography, but an extremely low pH mobile phase can cause instrument reliability problems and limit the choice of columns. Hydrophilic interaction chromatography is a potential alternative to reversed‐phase liquid chromatography for the separation of organic acids using more moderate conditions. However, the hydrophilic interaction chromatography separation mechanism is known to be very complex and involves multiple competing mechanisms. In the present study, a hydrophilic interaction chromatography column packed with bare silica core–shell particles was used as the separation column and six agricultural organic acids were used as model analytes to evaluate the effects of buffer concentration, buffer pH, and temperature on sample loading capacity, selectivity, retention, and repeatability. It was found that using a higher concentration of buffer can lead to a significant improvement in the overall performance and reproducibility of the separation. Investigation of column equilibration time revealed that a very long equilibration time is needed when changing mobile phase conditions in between runs. This limitation needs to be acknowledged in hydrophilic interaction chromatography method development and sufficient equilibration time needs to be allowed in method scouting.
- 23 April 2015
- Published by Wiley in Journal of Separation Science
- Vol. 38 (13) , 2253-2259
Hydrophilic interaction liquid chromatography for the separation of acidic agricultural compounds
Organic acids with very low pKa require extremely low pH conditions to achieve adequate retention in reversed‐phase liquid chromatography, but an extremely low pH mobile phase can cause instrument reliability problems and limit the choice of columns. Hydrophilic interaction chromatography is a potential alternative to reversed‐phase liquid chromatography for the separation of organic acids using more moderate conditions. However, the hydrophilic interaction chromatography separation mechanism is known to be very complex and involves multiple competing mechanisms. In the present study, a hydrophilic interaction chromatography column packed with bare silica core–shell particles was used as the separation column and six agricultural organic acids were used as model analytes to evaluate the effects of buffer concentration, buffer pH, and temperature on sample loading capacity, selectivity, retention, and repeatability. It was found that using a higher concentration of buffer can lead to a significant improvement in the overall performance and reproducibility of the separation. Investigation of column equilibration time revealed that a very long equilibration time is needed when changing mobile phase conditions in between runs. This limitation needs to be acknowledged in hydrophilic interaction chromatography method development and sufficient equilibration time needs to be allowed in method scouting.