Osamu Nishimura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Osamu Nishimura has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Chikako Toda
Life Science Laboratory, SHIMADZU CORPORATION, Kyoto, Japan
5 shared publicationsMakoto Watanabe
Life Science Laboratory, SHIMADZU CORPORATION, Kyoto, Japan
5 shared publicationsEiji Ando
Life Science Laboratory, SHIMADZU CORPORATION, Kyoto, Japan
3 shared publicationsHiroki Kuyama
Institute for Protein Research, Osaka University, Osaka, Japan
3 shared publicationsKoichi Tanaka
Koichi Tanaka Mass Spectrometry Research Laboratory, Shimadzu Corporation, Nakagyo-ku, Kyoto, Japan
3 shared publicationsSusumu Tsunasawa
Life Science Laboratory, SHIMADZU CORPORATION, Kyoto, Japan
3 shared publications
Latest Publications
- 1 December 2006
- Vol. 17 (5) , 333-41
Rapid and efficient MALDI-TOF MS peak detection of 2-nitrobenzenesulfenyl-labeled peptides using the combination of HPLC and an automatic spotting apparatus.
In this paper, we report MALDI-TOF ms analysis of 2-nitrobenzenesulfenyl (NBS) labeled peptides with the powerful aid of an LC-automatic spotting system. using this approach we analyzed mammalian sera (rat and mouse) as biological samples to demonstrate performance. The labeling was carried out using a binary set of 2-nitrobenzenesulfenyl chloride (heavy and light), which modified tryptophan residues in sample proteins. Approximately 1600 doublet peaks were detected in the mass spectrum, some of which had more than threefold differences in their intensities. systematic separation/spotting followed by mass analysis of the NBS-labeled peptides derived from biological samples is described for the first time. This method has proved to be an effective application of NBS-labeled peptides and can be a powerful technique for quantitative analysis of proteins expressed in biological systems.
- 1 December 2006
- Vol. 17 (5) , 333-41
Rapid and efficient MALDI-TOF MS peak detection of 2-nitrobenzenesulfenyl-labeled peptides using the combination of HPLC and an automatic spotting apparatus.
In this paper, we report MALDI-TOF ms analysis of 2-nitrobenzenesulfenyl (NBS) labeled peptides with the powerful aid of an LC-automatic spotting system. using this approach we analyzed mammalian sera (rat and mouse) as biological samples to demonstrate performance. The labeling was carried out using a binary set of 2-nitrobenzenesulfenyl chloride (heavy and light), which modified tryptophan residues in sample proteins. Approximately 1600 doublet peaks were detected in the mass spectrum, some of which had more than threefold differences in their intensities. systematic separation/spotting followed by mass analysis of the NBS-labeled peptides derived from biological samples is described for the first time. This method has proved to be an effective application of NBS-labeled peptides and can be a powerful technique for quantitative analysis of proteins expressed in biological systems.
- 22 March 2006
- Published by Wiley in Proteomics
- Vol. 6 (7) , 2042-2049
Selective detection of 2‐nitrobenzenesulfenyl‐labeled peptides by matrix‐assisted laser desorption/ionization‐time of flight mass spectrometry using a novel matrix
The 2‐nitrobenzenesulfenyl (NBS) method, which is useful for quantitative proteome analysis, is based on stable isotope labeling of tryptophan residues with NBS chloride (12C6‐NBSCl or 13C6‐NBSCl). We found that 3‐hydroxy‐4‐nitrobenzoic acid (3H4NBA) is a more suitable matrix than 2,5‐dihydroxybenzoic acid (DHB) for detecting NBS‐labeled peptides by MALDI‐quadrupole IT (QIT)‐TOF MS . Furthermore, NBS‐labeled peptides were selectively ionized and detected in a mixture of NBS‐labeled and unlabeled peptides. Labeled paired peaks were easily detected without enrichment, nonpaired labeled peaks were clearly distinguished from unlabeled contaminating peptides, and nitrotyrosine‐containing peptides were also selectively detected on the 3H4NBA matrix, while by‐product‐peaks arising from nitrobenzene moieties were suppressed. The use of 3H4NBA as a comatrix with CHCA improved the sensitivity of detection while substantially retaining the selectivity of 3H4NBA. The 3H4NBA matrix offers great advantages in terms of simplicity, sensitivity, and usability when used for the NBS method and for MALDI‐TOF MS analysis applied to compounds having a nitrobenzene ring.
- 22 March 2006
- Published by Wiley in Proteomics
- Vol. 6 (7) , 2042-2049
Selective detection of 2‐nitrobenzenesulfenyl‐labeled peptides by matrix‐assisted laser desorption/ionization‐time of flight mass spectrometry using a novel matrix
The 2‐nitrobenzenesulfenyl (NBS) method, which is useful for quantitative proteome analysis, is based on stable isotope labeling of tryptophan residues with NBS chloride (12C6‐NBSCl or 13C6‐NBSCl). We found that 3‐hydroxy‐4‐nitrobenzoic acid (3H4NBA) is a more suitable matrix than 2,5‐dihydroxybenzoic acid (DHB) for detecting NBS‐labeled peptides by MALDI‐quadrupole IT (QIT)‐TOF MS . Furthermore, NBS‐labeled peptides were selectively ionized and detected in a mixture of NBS‐labeled and unlabeled peptides. Labeled paired peaks were easily detected without enrichment, nonpaired labeled peaks were clearly distinguished from unlabeled contaminating peptides, and nitrotyrosine‐containing peptides were also selectively detected on the 3H4NBA matrix, while by‐product‐peaks arising from nitrobenzene moieties were suppressed. The use of 3H4NBA as a comatrix with CHCA improved the sensitivity of detection while substantially retaining the selectivity of 3H4NBA. The 3H4NBA matrix offers great advantages in terms of simplicity, sensitivity, and usability when used for the NBS method and for MALDI‐TOF MS analysis applied to compounds having a nitrobenzene ring.
- 24 November 2005
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (1) , 31-38
Improved 2‐nitrobenzenesulfenyl method: optimization of the protocol and improved enrichment for labeled peptides
We have developed the NBS (2‐nitrobenzenesulfenyl) method, a quantitative proteome analysis method utilizing stable isotope labeling followed by mass spectrometry. The potential of this method was reported previously, and the procedure has now been further optimized. Here, we describe a procedure utilizing urea or guanidine hydrochloride as a protein denaturant, in conjunction with an improved chromatographic enrichment method for the NBS‐labeled peptides using a phenyl resin column. By using this new protocol, both sample loss throughout the protocol and the elution of unwanted unlabeled peptides can be minimized, improving the efficiency of the analysis significantly. Copyright © 2005 John Wiley & Sons, Ltd.
- 24 November 2005
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (1) , 31-38
Improved 2‐nitrobenzenesulfenyl method: optimization of the protocol and improved enrichment for labeled peptides
We have developed the NBS (2‐nitrobenzenesulfenyl) method, a quantitative proteome analysis method utilizing stable isotope labeling followed by mass spectrometry. The potential of this method was reported previously, and the procedure has now been further optimized. Here, we describe a procedure utilizing urea or guanidine hydrochloride as a protein denaturant, in conjunction with an improved chromatographic enrichment method for the NBS‐labeled peptides using a phenyl resin column. By using this new protocol, both sample loss throughout the protocol and the elution of unwanted unlabeled peptides can be minimized, improving the efficiency of the analysis significantly. Copyright © 2005 John Wiley & Sons, Ltd.
- 11 June 2003
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 17 (14) , 1642-1650
An approach to quantitative proteome analysis by labeling tryptophan residues
This report describes a method for quantification and sequence identification of individual proteins in complex mixtures. The method is based on labeling with the chemical reagent 2‐nitrobenzenesulfenyl chloride (NBSCl) in conjunction with tandem mass spectrometry. In this method, selective introduction of the 2‐nitrobenzenesulfenyl (NBS) moiety onto tryptophan residues is achieved, and a 6 Da mass differential is generated using 13 C 6 ‐labeled NBSCl (NBSCl‐ 13 C 6 ) and 12 C 6 ‐labeled NBSCl (NBSCl‐ 12 C 6 ). The 6 Da mass differential between the NBS‐ 12 C 6 ‐labeled and the NBS‐ 13 C 6 ‐labeled peptides assigns a mass signature to all tryptophan‐containing peptides in any pool of proteolytic digests for protein identification through peptide mass mapping. Using this strategy, we compared the protein expression in rat sera using a normal (control) rat (Crj:Wistar) and a hyperglycemic rat (GK/Crj). The stable isotope dilution techniques used in this method provide highly accurate relative quantification. The NBS approach offers a widely applicable means of analyzing protein mixtures derived from biological samples, and the method described here presents an effective and simplified approach to proteome analysis. Copyright © 2003 John Wiley & Sons, Ltd.
- 11 June 2003
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 17 (14) , 1642-1650
An approach to quantitative proteome analysis by labeling tryptophan residues
This report describes a method for quantification and sequence identification of individual proteins in complex mixtures. The method is based on labeling with the chemical reagent 2‐nitrobenzenesulfenyl chloride (NBSCl) in conjunction with tandem mass spectrometry. In this method, selective introduction of the 2‐nitrobenzenesulfenyl (NBS) moiety onto tryptophan residues is achieved, and a 6 Da mass differential is generated using 13 C 6 ‐labeled NBSCl (NBSCl‐ 13 C 6 ) and 12 C 6 ‐labeled NBSCl (NBSCl‐ 12 C 6 ). The 6 Da mass differential between the NBS‐ 12 C 6 ‐labeled and the NBS‐ 13 C 6 ‐labeled peptides assigns a mass signature to all tryptophan‐containing peptides in any pool of proteolytic digests for protein identification through peptide mass mapping. Using this strategy, we compared the protein expression in rat sera using a normal (control) rat (Crj:Wistar) and a hyperglycemic rat (GK/Crj). The stable isotope dilution techniques used in this method provide highly accurate relative quantification. The NBS approach offers a widely applicable means of analyzing protein mixtures derived from biological samples, and the method described here presents an effective and simplified approach to proteome analysis. Copyright © 2003 John Wiley & Sons, Ltd.
- 23 May 2003
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 17 (13) , 1493-1496
An efficient chemical method for dephosphorylation of phosphopeptides
Phosphate moieties found on serine, threonine or tyrosine residues in peptides, e.g., in proteolytic digests of proteins, were cleaved using hydrofluoric acid or hydrogen fluoride–pyridine without side reactions. Copyright © 2003 John Wiley & Sons, Ltd.
- 23 May 2003
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 17 (13) , 1493-1496
An efficient chemical method for dephosphorylation of phosphopeptides
Phosphate moieties found on serine, threonine or tyrosine residues in peptides, e.g., in proteolytic digests of proteins, were cleaved using hydrofluoric acid or hydrogen fluoride–pyridine without side reactions. Copyright © 2003 John Wiley & Sons, Ltd.