IHIvan C. Ho

Ivan C. Ho

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ivan C. Ho has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • David S. Cannom

    Department of Cardiology, Good Samaritan Hospital, 1225 Wilshire Boulevard, Third floor, Los Angeles, CA 90017, USA

    2 shared publications
  • Andrew A. Zadeh

    Department of Cardiology, Good Samaritan Hospital, Los Angeles, California 90017, USA

    1 shared publication
  • Anil K. Bhandari

    Department of Cardiology, Good Samaritan Hospital, 1225 Wilshire Boulevard, Third floor, Los Angeles, CA 90017, USA

    1 shared publication
  • Bruce L. Macrum

    Department of Cardiology, Good Samaritan Hospital, Los Angeles, California, USA

    1 shared publication
  • Hitoshi Minamiguchi

    Department of Cardiology, Good Samaritan Hospital, 1225 Wilshire Boulevard, Third floor, Los Angeles, CA 90017, USA

    1 shared publication
  • Yosuke Miwa

    Department of Cardiology, Good Samaritan Hospital, 1225 Wilshire Boulevard, Third floor, Los Angeles, CA 90017, USA

    1 shared publication

Latest Publications

  • Open Access

    Amiodarone reduces the amount of ablation during catheter ablation for persistent atrial fibrillation

    by Yosuke Miwa, Hitoshi Minamiguchi, Anil K. Bhandari, David S. Cannom, Ivan C. Ho

    The step-wise approach to catheter ablation for persistent atrial fibrillation (AF) requires considerable substrate modification targeting at complex fractionated atrial electrograms (CFAEs) in addition to pulmonary vein (PV) isolation. An alternative strategy that minimizes the amount of ablation would be desirable. The aim of this study was to investigate whether the use of pre-procedural amiodarone affects: (i) the amount of ablation required to achieve procedural success, and (ii) long-term outcomes. We studied 121 consecutive patients with persistent AF who underwent catheter ablation. The patients were divided into two groups: Group 1, amiodarone (n = 31); Group 2, other antiarrhythmic drugs or rate control (n = 90). All the patients underwent a step-wise ablation procedure beginning with PV isolation, then proceeding with ablation of the CFAEs and linear lesions until sinus rhythm was achieved. Mean left atrial cycle length of AF (AFCL) was recorded at each step. The number of CFAE ablation sites was recorded. The number of CFAE sites in Group 1 was significantly less than that in Group 2 (P = 0.0121). The AFCLs after each step in Group 1 were significantly longer than those in Group 2. The procedure time and the radiofrequency time of CFAE ablation in Group 1 were significantly shorter than that in Group 2 (P = 0.0276 and P = 0.0458, respectively). There was no significant difference between the two groups in early and long-term outcomes. Use of pre-procedural amiodarone prolongs AFCL during catheter ablation and reduces the number of CFAE sites requiring ablation to achieve procedural success while maintaining equivalent long-term results.


  • The Use of Balloon Atrial Septostomy to Facilitate Difficult Transseptal Access in Patients Undergoing Catheter Ablation for Atrial Fibrillation

    by Andrew A. Zadeh, David S. Cannom, Bruce L. Macrum, Ivan C. Ho

    With the increasing number of patients undergoing repeat catheter ablation procedures for atrial fibrillation, it is not uncommon to encounter a fibrotic interatrial septum that resists the conventional manual advancement of the transseptal sheath. Forceful advancement of the transseptal apparatus can reduce fine control and potentially lead to a higher rate of perforation. We report a case where adjunctive balloon atrial septostomy was used to facilitate transseptal access in a patient with fibrotic interatrial septum. Using a small-caliber angioplasty balloon and under direct fluoroscopic and transesophageal echocardiogram visualization, balloon septostomy was performed with hand inflation until a "waist" was seen. This technique provides a safe way to control the size of the transseptal access created, and allows the passage of a relatively soft-tipped transseptal sheath across a resistive septum. To our knowledge this is the first published use of balloon atrial septostomy during transseptal puncture for left atrium access in a catheter ablation procedure. Balloon atrial septostomy should be considered as an alternative technique for safe transseptal cannulation in select patients in the electrophysiology laboratory or other interventional procedures requiring left atrial access or delivery of large-caliber catheters or sheaths.