BCBruce S. Cadarette

Bruce S. Cadarette

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bruce S. Cadarette has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Lou A. Stephenson

    U.S. Army Research Institute of Environmental Medicine , Kansas St., Natick, MA, 01760–5007, USA

    1 shared publication
  • Margaret A. Kolka

    U.S. Army Research Institute of Environmental Medicine , Kansas St., Natick, MA, 01760–5007, USA

    1 shared publication
  • Michael N Sawka

    1 shared publication
  • Michael N. Sawka

    U.S. Army Research Institute of Environmental Medicine , Kansas St., Natick, MA, 01760–5007, USA

    1 shared publication
  • Samuel N. Cheuvront

    U.S. Army Research Institute of Environmental Medicine , Kansas St., Natick, MA, 01760–5007, USA

    1 shared publication
  • Scott B Robinson

    1 shared publication

Latest Publications

    • 1 August 2007
      • Vol. 78  (8) , 809-13

    Reflective inserts to reduce heat strain in body armor: tests with and without irradiance.

    by Bruce S Cadarette, William R Santee, Scott B Robinson, Michael N Sawka

    This study evaluated adding reflective thermal inserts (RTI) to reduce the physiological strain during exercise-heat stress with a radiant load. RTI were used with a U.S. Army desert battle dress uniform, body armor, and helmet. Four male volunteers attempted four trials (10 min rest followed by 100 min walking at 1.56 m x s(-1)). All trials were at 40.0 degrees C dry bulb (Tdb), 12.4 degrees C dew point (Tdp), 20% RH, and 1.0 m x s(-1) wind speed. On 2 d, there was supplementary irradiance (+1) with globe temperature (Tbg) = 56.5 degrees C and on 2 d there was no supplementary irradiance (-I) with Tbg approximately Tdb. Trial conditions were: 1) RTI and armor with supplementary irradiance (RA+I); 2) plain armor with supplementary irradiance (PA+I); 3) RTI and armor with no supplementary irradiance (RA-I); and 4) plain armor with no supplementary irradiance (PA-I). Endurance times were not significantly different among trials. With one exception, armor and helmet interior and exterior surface temperatures were not significantly different between either RA+I and PA+I or RA-I and PA-I. Temperature on the inside of the helmet in RA+I (47.1 +/- 1.4 degrees C) was significantly lower than in PA+I (49.5 +/- 2.6 degrees C). There were no differences for any physiological measure (core temperature, heart rate, mean weighted skin temperature, forehead skin temperature, sweating rate, evaporative cooling, rate of heat storage) between either RA+I and PA+L or RA-I and PA-I. Results showed no evidence that wearing RTI with body armor and helmet reduces physiological strain during exercise-heat stress with either high or low irradiance.


  • Intermittent microclimate cooling during exercise-heat stress in US army chemical protective clothing

    by Bruce S. Cadarette, Samuel N. Cheuvront, Margaret A. Kolka, Lou A. Stephenson, Scott J. Montain, Michael N. Sawka

    The effectiveness of intermittent, microclimate cooling for men who worked in US Army chemical protective clothing (modified mission-oriented protective posture level 3; MOPP 3) was examined. The hypothesis was that intermittent cooling on a 2 min on–off schedule using a liquid cooling garment (LCG) covering 72% of the body surface area would reduce heat strain comparably to constant cooling. Four male subjects completed three experiments at 30°C, 30% relative humidity wearing the LCG under the MOPP 3 during 80 min of treadmill walking at 224 ± 5 W · m−2. Water temperature to the LCG was held constant at 21°C. The experiments were; 1) constant cooling (CC); 2) intermittent cooling at 2-min intervals (IC); 3) no cooling (NC). Core temperature increased (1.6 ± 0.2°C) in NC, which was greater than IC (0.5 ± 0.2°C) and CC (0.5 ± 0.3°C) ( p < 0.05). Mean skin temperature was higher during NC (36.1 ± 0.4°C) than IC (33.7 ± 0.6°C) and CC (32.6 ± 0.6°C) and mean skin temperature was higher during IC than CC ( p < 0.05). Mean heart rate during NC (139 ± 9 b · min−1) was greater than IC (110 ± 10 b · min−1) and CC (107 ± 9 b · min−1) ( p < 0.05). Cooling by conduction (K) during NC (94 ± 4 W · m−2) was lower than IC (142 ± 7 W · m−2) and CC (146 ± 4 W · m−2) ( p < 0.05). These findings suggest that IC provided a favourable skin to LCG gradient for heat dissipation by conduction and reduced heat strain comparable to CC during exercise-heat stress in chemical protective clothing.