Asif Abalal Momin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Asif Abalal Momin has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Nitin G. Chaubal
Department of Ultrasound, K.E.M. Hospital, Mumbai, India
1 shared publicationShenaz A Momin
B. Y. L. Nair Hospital, Mumbai, India
1 shared publicationShenaz G. A. Saifi
Department of Ultrasound, B.Y.L. Nair Hospital, Dr. A.L. Nair Road, Mumbai 400 008, India
1 shared publicationZubair N. Kazi
Department of Ultrasound, Prince Aly Khan Hospital, Nesbit Road, Mazagaon, Mumbai 400 010, India
1 shared publication
Latest Publications
- Open Access
- 1 August 2018
- Published by Georg Thieme Verlag KG in The Arab Journal of Interventional Radiology
- Vol. 02 (03) , P402
Reduce Confusion! Using Combined Contrast Ultrasound and Fusion Technique During Radiofrequency Ablation of Liver Space-occupying Lesions
Background: Purpose of this prospective study conducted in small oncology hospital is to highlight using either contrast-enhanced ultrasound (CEUS) with or without computed tomography (CT) fusion imaging to treat liver lesions well seen on positron emission tomography (PET)/CT or magnetic resonance imaging (MRI), but inconspicuous on ultrasound during radiofrequency and alcohol ablation of liver space-occupying lesions. Methods: Nine consecutive liver lesions; of size ranging from 1.2 to 4.7 cm; four metastatic and five primary HCC were subjected for US-guided radiofrequency or alcohol ablation earlier detected on either PET/CT or MRI. Using additional tools of CEUS or fusion imaging the pre, intra, and immediate post-RFA response was correctly judged; later confirmed on CT or PET study. In two cases, additional alcohol ablation was used to avoid heat sink effect due to main portal vein proximity and difficult RFA approach. Results: Except in two cases, all other lesions were considered as completely ablated based on pre- and post-CEUS enhancement pattern conducted before the patient was allowed to go home. One metastatic lesion showed definite peripheral enhancement and was reablated in additional sitting within next 2 h. In other case, CEUS showed minimal doubtful enhancement which on follow-up PET imaging was reported as post-RFA inflammatory response showing reducing standardized uptake values on repeat PET with absent enhancement on CEUS after 3 months. Conclusion: US guidance is at times handicapped by lack of confident identification of a lesion during ablation or by deciding the end-point of ablation merely on B-mode US due to difficulty in carrying out of immediate postablation PET/CT. This confusion can be minimized using real-time contrast US and fusion imaging to achieve the end-point. Publication Date: 11 May 2021 (online) © 2018. The Arab Journal of Interventional Radiology. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- 1 August 2018
- Published by Georg Thieme Verlag KG in The Arab Journal of Interventional Radiology
- Vol. 02 (03) , P402
Open AccessReduce Confusion! Using Combined Contrast Ultrasound and Fusion Technique During Radiofrequency Ablation of Liver Space-occupying Lesions
Background: Purpose of this prospective study conducted in small oncology hospital is to highlight using either contrast-enhanced ultrasound (CEUS) with or without computed tomography (CT) fusion imaging to treat liver lesions well seen on positron emission tomography (PET)/CT or magnetic resonance imaging (MRI), but inconspicuous on ultrasound during radiofrequency and alcohol ablation of liver space-occupying lesions. Methods: Nine consecutive liver lesions; of size ranging from 1.2 to 4.7 cm; four metastatic and five primary HCC were subjected for US-guided radiofrequency or alcohol ablation earlier detected on either PET/CT or MRI. Using additional tools of CEUS or fusion imaging the pre, intra, and immediate post-RFA response was correctly judged; later confirmed on CT or PET study. In two cases, additional alcohol ablation was used to avoid heat sink effect due to main portal vein proximity and difficult RFA approach. Results: Except in two cases, all other lesions were considered as completely ablated based on pre- and post-CEUS enhancement pattern conducted before the patient was allowed to go home. One metastatic lesion showed definite peripheral enhancement and was reablated in additional sitting within next 2 h. In other case, CEUS showed minimal doubtful enhancement which on follow-up PET imaging was reported as post-RFA inflammatory response showing reducing standardized uptake values on repeat PET with absent enhancement on CEUS after 3 months. Conclusion: US guidance is at times handicapped by lack of confident identification of a lesion during ablation or by deciding the end-point of ablation merely on B-mode US due to difficulty in carrying out of immediate postablation PET/CT. This confusion can be minimized using real-time contrast US and fusion imaging to achieve the end-point. Publication Date: 11 May 2021 (online) © 2018. The Arab Journal of Interventional Radiology. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- 21 June 2007
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 36 (1) , 42-44
Sonographic diagnosis of inferior mesenteric artery aneurysm and marginal artery of Drummond
We report the case of a patient in whom sonographic examination revealed an aneurysm of the inferior mesenteric artery with severe proximal stenosis and poststenotic dilatation—the enlargement of the proximal portion of the artery of Drummond. This collateral pathway should be kept in mind when studying bowel ischemia, especially when stenosis is present or when there is occlusion of the superior mesenteric artery. © 2007 Wiley Periodicals, Inc. J Clin Ultrasound, 2008
- 21 June 2007
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 36 (1) , 42-44
Sonographic diagnosis of inferior mesenteric artery aneurysm and marginal artery of Drummond
We report the case of a patient in whom sonographic examination revealed an aneurysm of the inferior mesenteric artery with severe proximal stenosis and poststenotic dilatation—the enlargement of the proximal portion of the artery of Drummond. This collateral pathway should be kept in mind when studying bowel ischemia, especially when stenosis is present or when there is occlusion of the superior mesenteric artery. © 2007 Wiley Periodicals, Inc. J Clin Ultrasound, 2008