Weihong Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Weihong Yang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Wlodzimierz Blasiak
Division of Energy and Furnace Technology, Department of Material Science and Engineering, School of Industrial Engineering and Management, KTH-Royal Institute of Technology, Brinellvägen 23, 10044 Stockholm, Sweden
2 shared publications Aliaksandr Alevanau
Division of Energy and Furnace Technology, ITM/MSE, KTH, Brinellvägen 23, 10044 Stockholm, Sweden
1 shared publicationMagnus Mortberg
Division of Energy and Furnace, Royal Institute of Technology, S-100 44 Stockholm, Sweden
1 shared publicationMagnus Mo¨rtberg
Royal Institute of Technology, Stockholm, Sweden
1 shared publication- Pawel Donaj
Division of Energy and Furnace Technology, ITM/MSE, KTH, Brinellvägen 23, 10044 Stockholm, Sweden
1 shared publication Simon Lille
Royal Institute of Technology, Stockholm, Sweden
1 shared publication
Latest Publications
- Open Access
- 22 May 2012
- Published by Hindawi Limited in ISRN Mechanical Engineering
- Vol. 2012, 1-10
Applicability of Scaling Approach for Analysis of Pyrolysis and Gasification of Porous Structures Composed of Solid Fuel Particles
Experimental research on the pyrolysis and gasification of randomly packed straw pellets was conducted with an emphasis on the reactive properties of the shrinking porous structure of the pellets. The apparent kinetics of such pyrolysis was approximated by the random pore, grain, and volumetric models. The best approximation results were obtained with the grain and random pore models. The self-organized oscillations of the pellet conversion rate during pyrolysis were observed. Two complementary explanations of the phenomenon are proposed.
- 22 May 2012
- Published by Hindawi Limited in ISRN Mechanical Engineering
- Vol. 2012, 1-10
Open AccessApplicability of Scaling Approach for Analysis of Pyrolysis and Gasification of Porous Structures Composed of Solid Fuel Particles
Experimental research on the pyrolysis and gasification of randomly packed straw pellets was conducted with an emphasis on the reactive properties of the shrinking porous structure of the pellets. The apparent kinetics of such pyrolysis was approximated by the random pore, grain, and volumetric models. The best approximation results were obtained with the grain and random pore models. The self-organized oscillations of the pellet conversion rate during pyrolysis were observed. Two complementary explanations of the phenomenon are proposed.
- 7 February 2005
- Published by Wiley in Scandinavian Journal of Metallurgy
- Vol. 34 (1) , 7-15
Influences of flame configurations on flame properties and NO emissions in combustion with high-temperature air
- 7 February 2005
- Published by Wiley in Scandinavian Journal of Metallurgy
- Vol. 34 (1) , 7-15
Influences of flame configurations on flame properties and NO emissions in combustion with high-temperature air
- 1 January 2002
- Published by ASME International
- p. 643-649
Heat Flux Evaluation in a Test Furnace Equipped With High Temperature Air Combustion (HTAC) Technique
High Temperature Air Combustion has already been applied in various industrial furnaces. Steel producers use most of the revamped furnaces. These are: • Batch and continuous heating furnaces in which HRS burners with open flames were used, • Batch and continuous heat treatment furnaces in which HRS burners with radiant tubes were used. Apart from steel industry the HTAC systems were applied to melt aluminium or to incinerate odour, vapour gases for example in pulp and paper industry. In all these applications very high fuel savings (sometimes as high as 60%), reduction of NOx and production increase (by 20–50%) was achieved. Progress in applications of the HTAC increased also needs of more information and data required by furnace and process designers. For this reason study in larger scale where at least one set of regenerative burner systems is installed are very much needed. Aim of such studies is not only to verify furnace performance with respect to the known general advantages of HTAC but are focused on specific problems related to furnace and high-cycle regenerative burners operation, process and product properties or type of fuels used. Parallel to the semi-industrial tests numerical models of furnaces have to be developed and verified. In this work, mainly results of heat flux measurements as well as results of numerical modeling of heat transfer in the HTAC test furnace are presented. Results were obtained for propane combustion at firing rate equal to 200 kW. The general code, STAR-CD, was employed in this work to analyse the HTAC test furnace numerically. HTAC test furnace at Royal Institute of Technology (KTH) with capacity of 200 kW was used in this work. The furnace is equipped with two different high-cycle regenerative systems (HRS). In both systems the “honeycomb” regenerator is used. The two-burner system is made of two pairs (four burners) of high cycle-regenerative burners with switching time between 10 and 40 seconds. HTAC test furnace is equipped with four air-cooled tubes to take away heat from the furnace. The total radiative heat flux measured in the HTAC furnace shows very uniform distribution over the whole combustion chamber. For total radiative heat flux, the values are in the range of 110–130 kW/m2 as measured by means of the total radiative heat flow meter at the furnace temperature 1100 C. Average total radiation flux on the top furnace wall is as high as 245.5 kW/m2 as well as total incident radiation flux. Total radiation heat flux on the air-cooled tube surface is very uniform along and around the tubes. Average radiant heat flux taken away by air cool tube is 35.46 kW/m2.
- 1 January 2002
- Published by ASME International
- p. 643-649
Heat Flux Evaluation in a Test Furnace Equipped With High Temperature Air Combustion (HTAC) Technique
High Temperature Air Combustion has already been applied in various industrial furnaces. Steel producers use most of the revamped furnaces. These are: • Batch and continuous heating furnaces in which HRS burners with open flames were used, • Batch and continuous heat treatment furnaces in which HRS burners with radiant tubes were used. Apart from steel industry the HTAC systems were applied to melt aluminium or to incinerate odour, vapour gases for example in pulp and paper industry. In all these applications very high fuel savings (sometimes as high as 60%), reduction of NOx and production increase (by 20–50%) was achieved. Progress in applications of the HTAC increased also needs of more information and data required by furnace and process designers. For this reason study in larger scale where at least one set of regenerative burner systems is installed are very much needed. Aim of such studies is not only to verify furnace performance with respect to the known general advantages of HTAC but are focused on specific problems related to furnace and high-cycle regenerative burners operation, process and product properties or type of fuels used. Parallel to the semi-industrial tests numerical models of furnaces have to be developed and verified. In this work, mainly results of heat flux measurements as well as results of numerical modeling of heat transfer in the HTAC test furnace are presented. Results were obtained for propane combustion at firing rate equal to 200 kW. The general code, STAR-CD, was employed in this work to analyse the HTAC test furnace numerically. HTAC test furnace at Royal Institute of Technology (KTH) with capacity of 200 kW was used in this work. The furnace is equipped with two different high-cycle regenerative systems (HRS). In both systems the “honeycomb” regenerator is used. The two-burner system is made of two pairs (four burners) of high cycle-regenerative burners with switching time between 10 and 40 seconds. HTAC test furnace is equipped with four air-cooled tubes to take away heat from the furnace. The total radiative heat flux measured in the HTAC furnace shows very uniform distribution over the whole combustion chamber. For total radiative heat flux, the values are in the range of 110–130 kW/m2 as measured by means of the total radiative heat flow meter at the furnace temperature 1100 C. Average total radiation flux on the top furnace wall is as high as 245.5 kW/m2 as well as total incident radiation flux. Total radiation heat flux on the air-cooled tube surface is very uniform along and around the tubes. Average radiant heat flux taken away by air cool tube is 35.46 kW/m2.