Angelo Salami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Angelo Salami has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Massimo Dellepiane
12 shared publicationsRenzo Mora
ENT Department, University of Genoa, Genoa, Italy
10 shared publicationsBarbara Crippa
8 shared publications- Luca Guastini
Department of Otorhinolaryngology, Università degli Studi di Genova, Italy
4 shared publications - Francesco Mora
Department of Otorhinolaryngology-Head and Neck Surgery, University of Genoa, Genoa, Italy
3 shared publications - Renzo Mora
ENT Department, University of Genoa, Italy
3 shared publications
Latest Publications
- 1 October 2010
- Vol. 39 (5) , 615-21
Computerized voice therapy in hypofunctional dysphonia.
The aim of this study was to analyze the efficiency and applicability of the Kay CSL 4500 system with the Sona-Speech II software model 3650 (Kay Pentax, Lincoln Park, NJ) in the voice therapy of patients affected by hypofunctional dysphonia. The study evaluated the effect of visual biofeedback, obtained with the Sona-Speech II software, on dysphonia associated with hypofunction dysphonia. The study was conducted with 40 male adults affected by hypofunctional dysphonia in the Otolaryngology Department of the University of Genoa (Italy) between April 2008 and April 2009. Before, at the end of, and 3 months after voice therapy, all subjects underwent an otolaryngology visit, videostroboscopy, and voice analysis through the Multi-Dimensional Voice Program (Kay Elemetrics, Lincoln Park, NJ) as an evaluation of nasal resonance and the Voice Handicap Index (VHI). Each cycle of rehabilitation was characterized by 30 daily consecutive sessions, each for 25 minutes. During each session, the patient was asked to perform specific computer exercises. The following acoustic parameters were estimated: average of fundamental frequency, percentage of jitter, shimmer, noise to harmonics ratio, voice turbulence index, soft phonation index, degree of voicelessness, degree of voice breaks, and peak amplitude variation. Our data showed significant (p < .05) improvements in acoustic and other parameters in the patients submitted to voice therapy. Our preliminary results suggest the applicability and efficiency of the Kay CSL 4500 system in association with the Sona-Speech II software model 3650 in a voice therapy program.
- 1 October 2010
- Vol. 39 (5) , 615-21
Computerized voice therapy in hypofunctional dysphonia.
The aim of this study was to analyze the efficiency and applicability of the Kay CSL 4500 system with the Sona-Speech II software model 3650 (Kay Pentax, Lincoln Park, NJ) in the voice therapy of patients affected by hypofunctional dysphonia. The study evaluated the effect of visual biofeedback, obtained with the Sona-Speech II software, on dysphonia associated with hypofunction dysphonia. The study was conducted with 40 male adults affected by hypofunctional dysphonia in the Otolaryngology Department of the University of Genoa (Italy) between April 2008 and April 2009. Before, at the end of, and 3 months after voice therapy, all subjects underwent an otolaryngology visit, videostroboscopy, and voice analysis through the Multi-Dimensional Voice Program (Kay Elemetrics, Lincoln Park, NJ) as an evaluation of nasal resonance and the Voice Handicap Index (VHI). Each cycle of rehabilitation was characterized by 30 daily consecutive sessions, each for 25 minutes. During each session, the patient was asked to perform specific computer exercises. The following acoustic parameters were estimated: average of fundamental frequency, percentage of jitter, shimmer, noise to harmonics ratio, voice turbulence index, soft phonation index, degree of voicelessness, degree of voice breaks, and peak amplitude variation. Our data showed significant (p < .05) improvements in acoustic and other parameters in the patients submitted to voice therapy. Our preliminary results suggest the applicability and efficiency of the Kay CSL 4500 system in association with the Sona-Speech II software model 3650 in a voice therapy program.
- 16 July 2010
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 130 (12) , 1364-1369
Piezoelectric stapedotomy: the importance of a micropulse program
Objectives: The aim of this study was to describe the importance of a micropulse program in determining the success of piezoelectric stapedotomy. Methods: A total of 112 patients (group A) affected by primary otosclerosis underwent piezoelectric stapedotomy for otosclerotic stapes fixation. A specific operative program was created to perforate the stapes footplate: this program makes it possible to perforate the footplate of the stapes with a predetermined and non-modifiable temporization. Before and 1 year after surgery, all the patients underwent the following instrumental examinations: pure-tone audiometry, tympanometry, transient-evoked otoacoustic emissions, distortion product otoacoustic emissions, and auditory brainstem response. Results were compared with those obtained from 30 patients who underwent piezoelectric stapedotomy without the specific operative program (group B). Results: At 1 year after surgery, with regard to the pure-tone audiometry test, all patients had an air-bone gap (ABG) reduction: no worsening of the bone conduction and no postoperative sensorineural hearing loss were found. In group A, there was a closure of the ABG within 10 dB in all patients. Conclusions: We can consider the micropulse program as the best level of safety that should be used in all cases of piezoelectric stapedotomy
- 16 July 2010
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 130 (12) , 1364-1369
Piezoelectric stapedotomy: the importance of a micropulse program
Objectives: The aim of this study was to describe the importance of a micropulse program in determining the success of piezoelectric stapedotomy. Methods: A total of 112 patients (group A) affected by primary otosclerosis underwent piezoelectric stapedotomy for otosclerotic stapes fixation. A specific operative program was created to perforate the stapes footplate: this program makes it possible to perforate the footplate of the stapes with a predetermined and non-modifiable temporization. Before and 1 year after surgery, all the patients underwent the following instrumental examinations: pure-tone audiometry, tympanometry, transient-evoked otoacoustic emissions, distortion product otoacoustic emissions, and auditory brainstem response. Results were compared with those obtained from 30 patients who underwent piezoelectric stapedotomy without the specific operative program (group B). Results: At 1 year after surgery, with regard to the pure-tone audiometry test, all patients had an air-bone gap (ABG) reduction: no worsening of the bone conduction and no postoperative sensorineural hearing loss were found. In group A, there was a closure of the ABG within 10 dB in all patients. Conclusions: We can consider the micropulse program as the best level of safety that should be used in all cases of piezoelectric stapedotomy
- 9 April 2010
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 130 (10) , 1119-1124
Results of revision mastoidectomy with Piezosurgery®
Conclusion: For otologic revision surgery, the advantage of the piezoelectric device appears real because it is possible to perform a ‘blind’ cutting of bone with fewer precautions necessary for soft tissues such as the facial nerve, lateral sinus, and dura mater. Objectives: The aim of this study was to determine the efficiency of the piezoelectric device in revision surgery for chronic otitis media. Methods: A total of 30 patients had revision mastoidectomy with previous canal wall up mastoidectomy. The piezoelectric device was used in all intraoperative steps. Before surgery and 1 month and 1 year after surgery, all the patients underwent the following instrumental examinations: pure-tone audiometry, tympanometry, transient-evoked otoacoustic emissions, distortion product otoacoustic emissions, auditory brainstem response, and electronystamographic recording. Results: The piezoelectric device provided effective cutting, with excellent control and without side effects on the adjacent structures of the middle and inner ear (lateral sinus, facial nerve, and/or dura mater). Postoperatively, all patients had an uneventful recovery with no evidence of audiovestibular deficit or side effects. Among 30 cases followed for 1 year, 29 (97%) maintained a dry and safe ear. Intermittent otorrhea with perforation of the tympanic membrane occurred in one patient (3%).
- 9 April 2010
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 130 (10) , 1119-1124
Results of revision mastoidectomy with Piezosurgery®
Conclusion: For otologic revision surgery, the advantage of the piezoelectric device appears real because it is possible to perform a ‘blind’ cutting of bone with fewer precautions necessary for soft tissues such as the facial nerve, lateral sinus, and dura mater. Objectives: The aim of this study was to determine the efficiency of the piezoelectric device in revision surgery for chronic otitis media. Methods: A total of 30 patients had revision mastoidectomy with previous canal wall up mastoidectomy. The piezoelectric device was used in all intraoperative steps. Before surgery and 1 month and 1 year after surgery, all the patients underwent the following instrumental examinations: pure-tone audiometry, tympanometry, transient-evoked otoacoustic emissions, distortion product otoacoustic emissions, auditory brainstem response, and electronystamographic recording. Results: The piezoelectric device provided effective cutting, with excellent control and without side effects on the adjacent structures of the middle and inner ear (lateral sinus, facial nerve, and/or dura mater). Postoperatively, all patients had an uneventful recovery with no evidence of audiovestibular deficit or side effects. Among 30 cases followed for 1 year, 29 (97%) maintained a dry and safe ear. Intermittent otorrhea with perforation of the tympanic membrane occurred in one patient (3%).
- 1 April 2010
- Vol. 39 (2) , 108-14
Stapedotomy with and without piezosurgery: 4 years' experience.
The aim of this study was to present our experiences and results of stapedotomy performed with and without the piezoelectric device. The article evaluates and compares the use of the piezoelectric device in performing primary stapedotomy in patients affected by otosclerosis with the traditional method of microdrilling. The study was conducted with 100 patients in the Department of Otolaryngology of the University of Genoa (Italy), between January 2007 and January 2008. A prospective, randomized, controlled trial was undertaken on 100 stapedotomy patients performed using the piezoelectric device (50 patients) or the microdrill (50 patients). Before surgery and at 1 and 12 months afterward, all patients underwent the following: otomicroscopic evaluation of the external and middle ear, pure-tone audiometry, tympanometry, transient evoked otoacoustic emissions, distortion product otoacoustic emissions, and auditory brainstem response. All patients treated with the piezoelectric device had an air-bone gap reduction, with a closure of the air-bone gap within 10 dB; 44 (88%) patients who underwent traditional surgery had an air-bone gap reduction, with a closure of the air-bone gap within 10 dB. All of our postoperative data confirm the safety of the device on the anatomic structures of the middle and inner ear and demonstrate the efficacy of the piezoelectric device in terms of safety, cutting precision, and protection of anatomic structures and its applicability to stapedotomy.
- 1 April 2010
- Vol. 39 (2) , 108-14
Stapedotomy with and without piezosurgery: 4 years' experience.
The aim of this study was to present our experiences and results of stapedotomy performed with and without the piezoelectric device. The article evaluates and compares the use of the piezoelectric device in performing primary stapedotomy in patients affected by otosclerosis with the traditional method of microdrilling. The study was conducted with 100 patients in the Department of Otolaryngology of the University of Genoa (Italy), between January 2007 and January 2008. A prospective, randomized, controlled trial was undertaken on 100 stapedotomy patients performed using the piezoelectric device (50 patients) or the microdrill (50 patients). Before surgery and at 1 and 12 months afterward, all patients underwent the following: otomicroscopic evaluation of the external and middle ear, pure-tone audiometry, tympanometry, transient evoked otoacoustic emissions, distortion product otoacoustic emissions, and auditory brainstem response. All patients treated with the piezoelectric device had an air-bone gap reduction, with a closure of the air-bone gap within 10 dB; 44 (88%) patients who underwent traditional surgery had an air-bone gap reduction, with a closure of the air-bone gap within 10 dB. All of our postoperative data confirm the safety of the device on the anatomic structures of the middle and inner ear and demonstrate the efficacy of the piezoelectric device in terms of safety, cutting precision, and protection of anatomic structures and its applicability to stapedotomy.
- 1 April 2010
- Vol. 39 (2) , 130-5
Binocular flash-induced nystagmus in humans.
The aim of this study was to demonstrate that binocular flash-induced nystagmus (B-FIN) can be evoked in humans. The study evaluated the presence of B-FIN by stimulation with a stroboscopic flash. The study was conducted with 12 healthy patients in the Otorhinolaryngology Department of the University of Genoa (Italy), between April 2008 and January 2009. Patients underwent binocular flashing light stimulation, in the dark, by stroboscopic flash presented through a photostimulator at frequencies of 4.7 and 7.69 cycles/second for 120 seconds, with their eyes covered by a homogeneous field hollow opal hemisphere. The photostimulator was placed in three different positions with respect to the anterior-posterior axis: 0 degrees, 45 degrees to the right, and 45 degrees to the left. Eye movements were recorded by electronystagmography (ENG). ENG recording started 30 seconds before the stimulation and stopped 60 seconds after the end of the luminance stimuli to test the presence of flash induced after nystagmus (FIAN). B-FIN was clearly evoked from 10 of the 12 healthy adults, whereas FIAN was evoked from 4 of the 12 subjects. The best stimulation of B-FIN was obtained through an intermittent luminance stimulus presented at a frequency of 4.7 cycles/second and the photostimulator placed at 0 degrees to the optic axis. Our investigation demonstrates that B-FIN can be evoked in humans and its possible value in the differential diagnosis between central and peripheral vertigo.
- 1 April 2010
- Vol. 39 (2) , 130-5
Binocular flash-induced nystagmus in humans.
The aim of this study was to demonstrate that binocular flash-induced nystagmus (B-FIN) can be evoked in humans. The study evaluated the presence of B-FIN by stimulation with a stroboscopic flash. The study was conducted with 12 healthy patients in the Otorhinolaryngology Department of the University of Genoa (Italy), between April 2008 and January 2009. Patients underwent binocular flashing light stimulation, in the dark, by stroboscopic flash presented through a photostimulator at frequencies of 4.7 and 7.69 cycles/second for 120 seconds, with their eyes covered by a homogeneous field hollow opal hemisphere. The photostimulator was placed in three different positions with respect to the anterior-posterior axis: 0 degrees, 45 degrees to the right, and 45 degrees to the left. Eye movements were recorded by electronystagmography (ENG). ENG recording started 30 seconds before the stimulation and stopped 60 seconds after the end of the luminance stimuli to test the presence of flash induced after nystagmus (FIAN). B-FIN was clearly evoked from 10 of the 12 healthy adults, whereas FIAN was evoked from 4 of the 12 subjects. The best stimulation of B-FIN was obtained through an intermittent luminance stimulus presented at a frequency of 4.7 cycles/second and the photostimulator placed at 0 degrees to the optic axis. Our investigation demonstrates that B-FIN can be evoked in humans and its possible value in the differential diagnosis between central and peripheral vertigo.
- 1 June 2009
- Vol. 15 (6) , CR269-73
Acoustic features of voice after septoplasty.
The aim of this study was to evaluate changes in acoustic features of voice after septoplasty and to establish concepts of patient management and a rational therapeutic approach. Before and one month after surgery, phonetically balanced sentences and sustained vowels a, e, and i were recorded and digitalized with MDVP (Multi Dimensional Voice Program, Kay Elemetrics) in all patients for an evaluation of nasal resonance, voice handicap index (VHI), and active anterior rhinomanometry. These parameters were estimated: average fundamental frequency (Fo), jitter percent, shimmer, noise-to-harmonics ratio (NHR), voice turbulence index (VTI), soft phonation index (SPI), degree of voicelessness (DUV), degree of voice breaks (DVB), and peak amplitude variation (vAm). One month after surgery the data showed an improvement in all the acoustic parameters and a normalization of nasalance. The results highlight the impact of septoplasty on nasalance and voice. In selected cases, such as severe nasal septum deviation, the decision to perform septoplasty depends on its potential effect on speech and respiratory function. An objective evaluation of voice and nasalance helps the specialist in the management of these patients.
- 1 June 2009
- Vol. 15 (6) , CR269-73
Acoustic features of voice after septoplasty.
The aim of this study was to evaluate changes in acoustic features of voice after septoplasty and to establish concepts of patient management and a rational therapeutic approach. Before and one month after surgery, phonetically balanced sentences and sustained vowels a, e, and i were recorded and digitalized with MDVP (Multi Dimensional Voice Program, Kay Elemetrics) in all patients for an evaluation of nasal resonance, voice handicap index (VHI), and active anterior rhinomanometry. These parameters were estimated: average fundamental frequency (Fo), jitter percent, shimmer, noise-to-harmonics ratio (NHR), voice turbulence index (VTI), soft phonation index (SPI), degree of voicelessness (DUV), degree of voice breaks (DVB), and peak amplitude variation (vAm). One month after surgery the data showed an improvement in all the acoustic parameters and a normalization of nasalance. The results highlight the impact of septoplasty on nasalance and voice. In selected cases, such as severe nasal septum deviation, the decision to perform septoplasty depends on its potential effect on speech and respiratory function. An objective evaluation of voice and nasalance helps the specialist in the management of these patients.
- 1 October 2008
- Vol. 37 (5) , 633-7
Harmonic scalpel in pharyngolaryngectomy with radical neck dissection.
The aim of this study was to verify the efficacy and applicability of the Ultracision Harmonic Scalpel (Ethicon Endo-Surgery, Cincinnati, OH) in pharyngolaryngectomy with radical neck dissection. This work evaluated the use of the Harmonic Scalpel in otolaryngology as a new and alternative method to overcome some complications of traditional surgery. The study was conducted with 20 patients in the ENT Department of the University of Genoa (Italy) between January 1, 2005, and December 31, 2006. A prospective, randomized study was undertaken on 20 pharyngolaryngectomies with radical neck dissection performed using a Harmonic Scalpel (10 patients) or traditional surgery (10 patients). The evaluation included operation time, intraoperative blood loss, postoperative seroma formation, and pattern of wound healing. In patients treated with Harmonic Scalpel, the mean operation time was significantly shorter, the blood loss was less, laryngeal and neck drainage on the first and second postoperative days was significantly smaller, and no postoperative complications were noted. The use of the Harmonic Scalpel during pharyngolaryngectomy and radical neck dissection led to diminished bleeding, shorter operative time, less seroma formation, and better wound healing in the postoperative period.
- 1 October 2008
- Vol. 37 (5) , 633-7
Harmonic scalpel in pharyngolaryngectomy with radical neck dissection.
The aim of this study was to verify the efficacy and applicability of the Ultracision Harmonic Scalpel (Ethicon Endo-Surgery, Cincinnati, OH) in pharyngolaryngectomy with radical neck dissection. This work evaluated the use of the Harmonic Scalpel in otolaryngology as a new and alternative method to overcome some complications of traditional surgery. The study was conducted with 20 patients in the ENT Department of the University of Genoa (Italy) between January 1, 2005, and December 31, 2006. A prospective, randomized study was undertaken on 20 pharyngolaryngectomies with radical neck dissection performed using a Harmonic Scalpel (10 patients) or traditional surgery (10 patients). The evaluation included operation time, intraoperative blood loss, postoperative seroma formation, and pattern of wound healing. In patients treated with Harmonic Scalpel, the mean operation time was significantly shorter, the blood loss was less, laryngeal and neck drainage on the first and second postoperative days was significantly smaller, and no postoperative complications were noted. The use of the Harmonic Scalpel during pharyngolaryngectomy and radical neck dissection led to diminished bleeding, shorter operative time, less seroma formation, and better wound healing in the postoperative period.
- 1 May 2008
- Vol. 14 (5) , PI1-5
New trends in head and neck surgery: a prospective evaluation of the Harmonic Scalpel.
The use of ultrasonic technology to cut and coagulate tissues with minimal tissue damage has been investigated in general surgery and gynecology. The purpose of this study was to verify the efficacy and applicability of the Harmonic Scalpel in head and neck surgery. A non-randomized study was undertaken on 40 pharyngolaryngectomies, 40 total laryngectomies, 40 radical neck dissections, and 40 superficial parotidectomies performed using the Harmonic Scalpel (80 patients) or "cold knife" dissection (80 patients). The evaluation included operation time, intraoperative blood loss, quantity of neck drainage on the first and second postoperative days, postoperative seroma formation, pattern of wound healing, days of hospitalization, and subjective assessment of postoperative pain. In patients treated with the Harmonic Scalpel, the mean operation time was significantly (p<0.05) shorter (119.1+/-1.35 vs. 156.9+/-1.51), intraoperative blood loss (121.5+/-1.28 vs. 257.5+/-2.32) and the quantity of neck drainage on the first (47+/-0.87 vs. 89+/-1.28) and second (38.7+/-0.86 vs. 75.5+/-1.34) postoperative days were significantly less, and the days of hospitalization (6.67+/-0.48 vs. 8.8+/-0.58) and the pain scores (3.24+/-0.63 vs. 5.91+/-0.83) were significantly lower than in the "cold knife" group. No postoperative complications were noted in the Harmonic Scalpel group. The use of the Harmonic Scalpel in head and neck surgery is safe and confers some advantages over conventional methods of head and neck dissection.
- 1 May 2008
- Vol. 14 (5) , PI1-5
New trends in head and neck surgery: a prospective evaluation of the Harmonic Scalpel.
The use of ultrasonic technology to cut and coagulate tissues with minimal tissue damage has been investigated in general surgery and gynecology. The purpose of this study was to verify the efficacy and applicability of the Harmonic Scalpel in head and neck surgery. A non-randomized study was undertaken on 40 pharyngolaryngectomies, 40 total laryngectomies, 40 radical neck dissections, and 40 superficial parotidectomies performed using the Harmonic Scalpel (80 patients) or "cold knife" dissection (80 patients). The evaluation included operation time, intraoperative blood loss, quantity of neck drainage on the first and second postoperative days, postoperative seroma formation, pattern of wound healing, days of hospitalization, and subjective assessment of postoperative pain. In patients treated with the Harmonic Scalpel, the mean operation time was significantly (p<0.05) shorter (119.1+/-1.35 vs. 156.9+/-1.51), intraoperative blood loss (121.5+/-1.28 vs. 257.5+/-2.32) and the quantity of neck drainage on the first (47+/-0.87 vs. 89+/-1.28) and second (38.7+/-0.86 vs. 75.5+/-1.34) postoperative days were significantly less, and the days of hospitalization (6.67+/-0.48 vs. 8.8+/-0.58) and the pain scores (3.24+/-0.63 vs. 5.91+/-0.83) were significantly lower than in the "cold knife" group. No postoperative complications were noted in the Harmonic Scalpel group. The use of the Harmonic Scalpel in head and neck surgery is safe and confers some advantages over conventional methods of head and neck dissection.
- 31 January 2008
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 72 (1) , 1-7
Visual–vestibular interaction test in the diagnosis of vertigo in children
- 31 January 2008
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 72 (1) , 1-7
Visual–vestibular interaction test in the diagnosis of vertigo in children
- 1 December 2007
- Vol. 13 (12) , PI25-9
Piezosurgery in the excision of middle-ear tumors: effects on mineralized and non-mineralized tissues.
Piezosurgery is a new instrument able to cut bone without necrosis and non-mineralized tissue damage. The aim of this study was to test the Piezosurgery as a new and alternative method for the excision of middle-ear tumors and to analyze its effects on soft tissues. The Piezosurgery device was used to excise eight glomus tympanicum tumors and two primary B-cell lymphomas of the middle ear. The piezoelectric device uses low-frequency ultrasonic waves (24.7-29.5 kHz); the applied power can be modulated between 2.8 and 16 W and is programmed in accordance to the density of the bone. The equipment consists of two hand-pieces, two inserts, and two peristaltic pumps. The microvibrations that are created in the piezoelectric hand-piece cause the inserts to vibrate linearly by between 60 and 210 microm. Piezosurgery provided excellent control in all the patients, without bleeding and harmful effects on the adjacent structures of the middle and inner ear. Piezosurgery is a new and revolutionary osteotomy technique utilizing the microvibrations of scalpels at ultrasonic frequency, so that soft tissue will not be damaged even upon accidental contact with the cutting tip. The vibration frequency of Piezosurgery is optimal for mineralized tissue and does not cut the adjacent soft tissue, minimizing the risk of harming the adjacent tissues. This renders the piezoelectric device ideal for application at the border between hard and soft tissues as in the excision of a middle-ear tumor.
- 1 December 2007
- Vol. 13 (12) , PI25-9
Piezosurgery in the excision of middle-ear tumors: effects on mineralized and non-mineralized tissues.
Piezosurgery is a new instrument able to cut bone without necrosis and non-mineralized tissue damage. The aim of this study was to test the Piezosurgery as a new and alternative method for the excision of middle-ear tumors and to analyze its effects on soft tissues. The Piezosurgery device was used to excise eight glomus tympanicum tumors and two primary B-cell lymphomas of the middle ear. The piezoelectric device uses low-frequency ultrasonic waves (24.7-29.5 kHz); the applied power can be modulated between 2.8 and 16 W and is programmed in accordance to the density of the bone. The equipment consists of two hand-pieces, two inserts, and two peristaltic pumps. The microvibrations that are created in the piezoelectric hand-piece cause the inserts to vibrate linearly by between 60 and 210 microm. Piezosurgery provided excellent control in all the patients, without bleeding and harmful effects on the adjacent structures of the middle and inner ear. Piezosurgery is a new and revolutionary osteotomy technique utilizing the microvibrations of scalpels at ultrasonic frequency, so that soft tissue will not be damaged even upon accidental contact with the cutting tip. The vibration frequency of Piezosurgery is optimal for mineralized tissue and does not cut the adjacent soft tissue, minimizing the risk of harming the adjacent tissues. This renders the piezoelectric device ideal for application at the border between hard and soft tissues as in the excision of a middle-ear tumor.