Thomas Balkany
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Thomas Balkany has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
A V Hodges
Department of Otolaryngology-Head and Neck Surgery, University of Miami Ear Institute, Florida, USA
6 shared publicationsAnnelle V. Hodges
2 shared publicationsD Lee
2 shared publicationsF F Telischi
2 shared publicationsM Luntz
2 shared publicationsS Butts
2 shared publications
Latest Publications
- 31 August 2005
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 133 (2) , P229
Temporal Bone Resection for EAC Carcinoma: Positive Margins and Recurrences
- 31 August 2005
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 133 (2) , P229
Temporal Bone Resection for EAC Carcinoma: Positive Margins and Recurrences
- 1 July 1999
- Vol. 20 (4) , 453-6
Speech recognition after implantation of the ossified cochlea.
Insertion of complex, multichannel cochlear implant (CI) electrode arrays into ossified cochleas is now performed routinely. This study describes the hearing results obtained in a consecutive series of 21 patients with obstructed cochleas and compares these results to those in patients with open cochleas. The purpose of this study was to determine whether patients with ossification have speech perception results that are inferior to those of patients with no evidence of cochlear bone formation. Retrospective analysis of consecutive clinical series. CI database review of 191 CI procedures at the University of Miami Ear Institute between 1990 and 1997 showed that 24 (13%) procedures were performed on patients with ossified cochleas. Open-set speech recognition scores obtained on the 11 pediatric and 7 adult English-speaking patients are compared to scores of 51 adult and 61 pediatric English-speaking CI patients with open scala. Results of open-set speech recognition measures in adults and children with ossified cochleas were not significantly different from those of the reference groups. Speech recognition results of patients with ossified cochleas are essentially equal to those of patients with open cochleas. Degree of obstruction appears to have less effect on outcome than other factors such as duration of profound deafness or communication methodology in children among this group.
- 1 July 1999
- Vol. 20 (4) , 453-6
Speech recognition after implantation of the ossified cochlea.
Insertion of complex, multichannel cochlear implant (CI) electrode arrays into ossified cochleas is now performed routinely. This study describes the hearing results obtained in a consecutive series of 21 patients with obstructed cochleas and compares these results to those in patients with open cochleas. The purpose of this study was to determine whether patients with ossification have speech perception results that are inferior to those of patients with no evidence of cochlear bone formation. Retrospective analysis of consecutive clinical series. CI database review of 191 CI procedures at the University of Miami Ear Institute between 1990 and 1997 showed that 24 (13%) procedures were performed on patients with ossified cochleas. Open-set speech recognition scores obtained on the 11 pediatric and 7 adult English-speaking patients are compared to scores of 51 adult and 61 pediatric English-speaking CI patients with open scala. Results of open-set speech recognition measures in adults and children with ossified cochleas were not significantly different from those of the reference groups. Speech recognition results of patients with ossified cochleas are essentially equal to those of patients with open cochleas. Degree of obstruction appears to have less effect on outcome than other factors such as duration of profound deafness or communication methodology in children among this group.
- 1 January 1999
- Vol. 20 (1) , 53-5
Hearing results with deep insertion of cochlear implant electrodes.
This study aimed to investigate the relationship of electrode insertion length and speech recognition in patients using Nucleus-22 cochlear implants. The study design was a retrospective review of a consecutive clinical series. The study was conducted at an academic medical center. Thirty-one postlingually deafened adults with at least 6 months' experience with a Nucleus-22 cochlear implant using Spectra-22 processor and SPEAK strategy participated. Open-set speech recognition scores for words and sentences were measured. Insertion length ranged from 22 rings (estimated 17 mm) to 32 rings (estimated 25 mm). Mean word recognition score was 35%. Mean sentence score was 69.6%. Statistical analysis showed no correlation between insertion depth and word or sentence scores. Insertion of the Nucleus-22 array beyond 22 rings does not improve performance in speech recognition. This finding cannot be generalized to other electrodes or processing strategies.
- 1 January 1999
- Vol. 20 (1) , 53-5
Hearing results with deep insertion of cochlear implant electrodes.
This study aimed to investigate the relationship of electrode insertion length and speech recognition in patients using Nucleus-22 cochlear implants. The study design was a retrospective review of a consecutive clinical series. The study was conducted at an academic medical center. Thirty-one postlingually deafened adults with at least 6 months' experience with a Nucleus-22 cochlear implant using Spectra-22 processor and SPEAK strategy participated. Open-set speech recognition scores for words and sentences were measured. Insertion length ranged from 22 rings (estimated 17 mm) to 32 rings (estimated 25 mm). Mean word recognition score was 35%. Mean sentence score was 69.6%. Statistical analysis showed no correlation between insertion depth and word or sentence scores. Insertion of the Nucleus-22 array beyond 22 rings does not improve performance in speech recognition. This finding cannot be generalized to other electrodes or processing strategies.
- 1 July 1998
- Published by Wiley in The Laryngoscope
- Vol. 108 (7) , 988-992
Surgical technique for implantation of the totally ossified cochlea
Objectives: Among the technical challenges of cochlear implant surgery is electrode insertion into the fully ossified cochlea. Earlier drill‐out techniques have two significant drawbacks: 1. up to one half fail when the electrode pulls away from the cochlea; and 2. extended radical mastoidectomy, abdominal fat graft for obliteration, and closure of the external auditory meatus are required. A simplified technique is described that allows positive fixation of the cochlear implant electrode and in selected cases avoids a radical cavity with obliteration. Study Design: Technical description with case reports and hearing outcomes. Methods: Ten cadaver temporal bones were dissected to determine middle ear landmarks that overlie the basal turn of the cochlea from the transcanal approach and to establish the feasibility of the intact canal wall procedure. Surgery was performed on four patients who had preoperative imaging evidence of full ossification, two with the canal wall down, and two with canal wall up. Standard measures of speech recognition were used to evaluate hearing. Results: Critical surgical landmarks are the round window, carotid artery, cochleariform process, and oval window. The procedure was successfully performed on four patients and open‐set speech recognition is present in each. Conclusions: This canal wall up procedure allows long electrode insertion without radical cavity/obliteration in patients with fully ossified cochleas and prevents distraction of the electrode from the cochlea. While open‐set word recognition was achieved by all subjects, results are poorer than expected for patients with limited or no ossification.
- 1 July 1998
- Published by Wiley in The Laryngoscope
- Vol. 108 (7) , 988-992
Surgical technique for implantation of the totally ossified cochlea
Objectives: Among the technical challenges of cochlear implant surgery is electrode insertion into the fully ossified cochlea. Earlier drill‐out techniques have two significant drawbacks: 1. up to one half fail when the electrode pulls away from the cochlea; and 2. extended radical mastoidectomy, abdominal fat graft for obliteration, and closure of the external auditory meatus are required. A simplified technique is described that allows positive fixation of the cochlear implant electrode and in selected cases avoids a radical cavity with obliteration. Study Design: Technical description with case reports and hearing outcomes. Methods: Ten cadaver temporal bones were dissected to determine middle ear landmarks that overlie the basal turn of the cochlea from the transcanal approach and to establish the feasibility of the intact canal wall procedure. Surgery was performed on four patients who had preoperative imaging evidence of full ossification, two with the canal wall down, and two with canal wall up. Standard measures of speech recognition were used to evaluate hearing. Results: Critical surgical landmarks are the round window, carotid artery, cochleariform process, and oval window. The procedure was successfully performed on four patients and open‐set speech recognition is present in each. Conclusions: This canal wall up procedure allows long electrode insertion without radical cavity/obliteration in patients with fully ossified cochleas and prevents distraction of the electrode from the cochlea. While open‐set word recognition was achieved by all subjects, results are poorer than expected for patients with limited or no ossification.
- 1 November 1997
- Vol. 18, S58-9
Intact canal wall drill-out procedure for implantation of the totally ossified cochlea.
To describe a simplified drill-out technique for insertion of a multichannel electrode in the completely ossified cochlea without radical mastoidectomy and obliteration. Description of a new surgical technique and case report. Temporal bone dissection laboratory and tertiary referral center. Adult and pediatric cochlear implant (CI) recipients. Access for circum-modular drill-out and electrode insertion without radical mastoidectomy and adequate function of multichannel CI. Dissection of 10 cadaver temporal bones demonstrated feasibility of this technique. Highlights include facial recess cochleostomy and 8 mm tunnel; elevation of superiorly based tympanomeatal flap; removal of incus, cochleariform process, and tensor tympani; and identification of carotid canal and use of facial nerve monitor. A case report of an 11-year-year old child with total cochlear ossification and previous failure of a short (8 electrode) CI electrode insertion is presented. Complete insertion of a 22-channel electrode was successful and open-set word recognition is commencing. The canal wall-up drill-out procedure allows complete electrode insertion without mastoid obliteration in patients with obliterated cochleas. Appropriate attention to the carotid artery and facial nerve is essential.
- 1 November 1997
- Vol. 18, S58-9
Intact canal wall drill-out procedure for implantation of the totally ossified cochlea.
To describe a simplified drill-out technique for insertion of a multichannel electrode in the completely ossified cochlea without radical mastoidectomy and obliteration. Description of a new surgical technique and case report. Temporal bone dissection laboratory and tertiary referral center. Adult and pediatric cochlear implant (CI) recipients. Access for circum-modular drill-out and electrode insertion without radical mastoidectomy and adequate function of multichannel CI. Dissection of 10 cadaver temporal bones demonstrated feasibility of this technique. Highlights include facial recess cochleostomy and 8 mm tunnel; elevation of superiorly based tympanomeatal flap; removal of incus, cochleariform process, and tensor tympani; and identification of carotid canal and use of facial nerve monitor. A case report of an 11-year-year old child with total cochlear ossification and previous failure of a short (8 electrode) CI electrode insertion is presented. Complete insertion of a 22-channel electrode was successful and open-set word recognition is commencing. The canal wall-up drill-out procedure allows complete electrode insertion without mastoid obliteration in patients with obliterated cochleas. Appropriate attention to the carotid artery and facial nerve is essential.
- 1 November 1997
- Vol. 18, S66
Surgical techniques for cochlear implantation of the malformed inner ear.
The objective was to describe surgical techniques helpful in implanting children with inner ear malformations. This was a retrospective chart review and description of surgical techniques in the setting of a tertiary referral center. The study population was composed of 10 children with inner ear deformities who received 22-channel implants. The primary surgical challenges encountered in these procedures include complete electrode insertion, cerebrospinal fluid gusher, identification of cochleostomy site in the absence of the round window and aberrant facial nerve, and fixation and stabilization of the electrode. The techniques described allow safe and effective insertion of multichannel electrodes in patients with inner ear malformations.
- 1 November 1997
- Vol. 18, S66
Surgical techniques for cochlear implantation of the malformed inner ear.
The objective was to describe surgical techniques helpful in implanting children with inner ear malformations. This was a retrospective chart review and description of surgical techniques in the setting of a tertiary referral center. The study population was composed of 10 children with inner ear deformities who received 22-channel implants. The primary surgical challenges encountered in these procedures include complete electrode insertion, cerebrospinal fluid gusher, identification of cochleostomy site in the absence of the round window and aberrant facial nerve, and fixation and stabilization of the electrode. The techniques described allow safe and effective insertion of multichannel electrodes in patients with inner ear malformations.
- 1 November 1997
- Vol. 18, S115
Single electrode maps in device troubleshooting.
This article presents case studies in which single-channel mapping was used with patients who were experiencing discomfort while using their cochlear implant devices. Repeated psychophysical testing together with integrity testing had failed to locate the source of the problem in each of the described cases. Single-channel mapping was then used as another means of device troubleshooting. Single-channel maps were created for each electrode across the array. In each case, the patient was able to identify the offending electrode(s) during the presentation of speech stimuli, whereas the problem had not been evident during psychophysical testing with pulse stimuli. Eliminating these electrodes from the map alleviated the problems experienced by these implant users in each case.
- 1 November 1997
- Vol. 18, S115
Single electrode maps in device troubleshooting.
This article presents case studies in which single-channel mapping was used with patients who were experiencing discomfort while using their cochlear implant devices. Repeated psychophysical testing together with integrity testing had failed to locate the source of the problem in each of the described cases. Single-channel mapping was then used as another means of device troubleshooting. Single-channel maps were created for each electrode across the array. In each case, the patient was able to identify the offending electrode(s) during the presentation of speech stimuli, whereas the problem had not been evident during psychophysical testing with pulse stimuli. Eliminating these electrodes from the map alleviated the problems experienced by these implant users in each case.
- 1 August 1997
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 117 (2) , P153-P154
Speech perception results in children with cochlear implants
- 1 August 1997
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 117 (2) , P153-P154
Speech perception results in children with cochlear implants
- 1 March 1997
- Vol. 18 (2) , 179-83
Conservation of residual hearing with cochlear implantation.
The goals of this work were (a) to review the pre- and postsurgical auditory thresholds in a consecutive sample of cochlear implant recipients to determine the fate of residual hearing, and (b) to obtain preliminary indication of the value of a multicenter longitudinal study of residual hearing in implant patients. Indications for cochlear implantation have been expanded to include severely hearing impaired (SHI) adults and may someday include SHI children. Implantation of individuals with more residual hearing is a concern owing to the possible development of better devices that may make use of residual hearing within the lifetime of implanted children if not that of adults. Preservation of residual hearing would be a desirable outcome of implant surgery; however, conventional thought is that implantation destroys any remaining hearing. This study was undertaken to assess if and how often conservation of hearing occurred after implantation in a sample of multichannel implant recipients. Records of 50 profoundly hearing impaired consecutively implanted patients were examined for pre- and post-surgical audiometric results. Standard audiometric techniques were used for all testing procedures. Forty patients were considered to have some hearing conserved based on a response obtained at any one of the three speech frequencies prior to implantation. The most recent postimplantation audiometric results were used providing data from users with 1-41 months of use. Twenty-one of 40 implanted subjects were found to have responses in at least one of the speech frequencies both pre- and postsurgery, with the majority of those displaying responses at all three frequencies. In this preliminary retrospective study, it did not appear that duration of cochlear implant use, gender, level of preoperative hearing, or length of electrode insertion were related to outcome. There were insufficient data to draw conclusions on individual devices. Conservation of hearing occurred in approximately half of the subjects reviewed. There is no indication of what factors contributed to the preservation of hearing in those with postsurgical residual hearing or if that hearing is usable. The study does suggest that a larger multicenter longitudinal study would be of value of determine what factors may be related to conserved hearing in implanted patients.
- 1 March 1997
- Vol. 18 (2) , 179-83
Conservation of residual hearing with cochlear implantation.
The goals of this work were (a) to review the pre- and postsurgical auditory thresholds in a consecutive sample of cochlear implant recipients to determine the fate of residual hearing, and (b) to obtain preliminary indication of the value of a multicenter longitudinal study of residual hearing in implant patients. Indications for cochlear implantation have been expanded to include severely hearing impaired (SHI) adults and may someday include SHI children. Implantation of individuals with more residual hearing is a concern owing to the possible development of better devices that may make use of residual hearing within the lifetime of implanted children if not that of adults. Preservation of residual hearing would be a desirable outcome of implant surgery; however, conventional thought is that implantation destroys any remaining hearing. This study was undertaken to assess if and how often conservation of hearing occurred after implantation in a sample of multichannel implant recipients. Records of 50 profoundly hearing impaired consecutively implanted patients were examined for pre- and post-surgical audiometric results. Standard audiometric techniques were used for all testing procedures. Forty patients were considered to have some hearing conserved based on a response obtained at any one of the three speech frequencies prior to implantation. The most recent postimplantation audiometric results were used providing data from users with 1-41 months of use. Twenty-one of 40 implanted subjects were found to have responses in at least one of the speech frequencies both pre- and postsurgery, with the majority of those displaying responses at all three frequencies. In this preliminary retrospective study, it did not appear that duration of cochlear implant use, gender, level of preoperative hearing, or length of electrode insertion were related to outcome. There were insufficient data to draw conclusions on individual devices. Conservation of hearing occurred in approximately half of the subjects reviewed. There is no indication of what factors contributed to the preservation of hearing in those with postsurgical residual hearing or if that hearing is usable. The study does suggest that a larger multicenter longitudinal study would be of value of determine what factors may be related to conserved hearing in implanted patients.
- 1 April 1996
- Published by Elsevier in Otolaryngologic Clinics of North America
- Vol. 29 (2) , 277-289
Update On Cochlear Implantation
- 1 April 1996
- Published by Elsevier in Otolaryngologic Clinics of North America
- Vol. 29 (2) , 277-289
Update On Cochlear Implantation