Peter J. Cumpson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Peter J. Cumpson has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- John Hedley
School of Engineering, Newcastle University, Newcastle upon Tyne NE1 7RU, UK
4 shared publications - Charles A. Clifford
National Physical Laboratory
2 shared publications - Stephanie Allen
School of Pharmacy, The University of Nottingham, University Park, Nottingham NG7 2RD, UK
2 shared publications José F. Portolés
Laboratory of Biophysics and Surface Analysis , University of Nottingham , Nottingham, NG72RD, UK
1 shared publicationPeter Zhdan
1 shared publication- Philip Michael Williams
Molecular Therapeutics and Formulation, School of Pharmacy, University of Nottingham, Nottingham, UK
1 shared publication
Latest Publications
- Open Access
- 1 March 2006
- Published by Taylor & Francis in Journal of Experimental Nanoscience
- Vol. 1 (1) , 51-62
Accurate velocity measurements of AFM-cantilever vibrations by Doppler interferometry
Doppler velocimetry is widely used in the measurement of nanometre resonance vibrations of micro-electromechanical systems (MEMS). It has excellent sensitivity and precision, but typical engineering applications do not require traceability of these velocity measurements to the SI system. While Doppler velocimetry is, in principle, easy to make traceable to the velocity of light, in practice a frequency-to-voltage conversion in common commercial instruments breaks this traceability unless calibrated. Typically, though, calibration is performed at a much lower frequency than those typical of MEMS devices, without the guarantee that the calibration is applicable in this higher frequency regime. We present a method of traceable measurement of velocity in terms of the velocity of light, valid for the range of frequency and nanometre amplitudes typical of MEMS devices driven to resonance vibration. This is achieved by analysis of sideband amplitudes in the interference spectrum before demodulation of the Doppler signal. These sideband amplitudes can conveniently be measured using a benchtop spectrum analyser, a piece of widely available electrical test equipment. We illustrate the method with measurements on individual AFM cantilevers. In combination with cantilever calibration methods based on MEMS devices this method enables traceable calibration of those cantilevers employed for the measurement of pico- and nanonewton forces between individual biomolecules.
- 1 March 2006
- Published by Taylor & Francis in Journal of Experimental Nanoscience
- Vol. 1 (1) , 51-62
Open AccessAccurate velocity measurements of AFM-cantilever vibrations by Doppler interferometry
Doppler velocimetry is widely used in the measurement of nanometre resonance vibrations of micro-electromechanical systems (MEMS). It has excellent sensitivity and precision, but typical engineering applications do not require traceability of these velocity measurements to the SI system. While Doppler velocimetry is, in principle, easy to make traceable to the velocity of light, in practice a frequency-to-voltage conversion in common commercial instruments breaks this traceability unless calibrated. Typically, though, calibration is performed at a much lower frequency than those typical of MEMS devices, without the guarantee that the calibration is applicable in this higher frequency regime. We present a method of traceable measurement of velocity in terms of the velocity of light, valid for the range of frequency and nanometre amplitudes typical of MEMS devices driven to resonance vibration. This is achieved by analysis of sideband amplitudes in the interference spectrum before demodulation of the Doppler signal. These sideband amplitudes can conveniently be measured using a benchtop spectrum analyser, a piece of widely available electrical test equipment. We illustrate the method with measurements on individual AFM cantilevers. In combination with cantilever calibration methods based on MEMS devices this method enables traceable calibration of those cantilevers employed for the measurement of pico- and nanonewton forces between individual biomolecules.
- 1 August 2004
- Published by Elsevier in Ultramicroscopy
- Vol. 100 (3-4) , 241-251
Calibration of AFM cantilever stiffness: a microfabricated array of reflective springs
- 1 August 2004
- Published by Elsevier in Ultramicroscopy
- Vol. 100 (3-4) , 241-251
Calibration of AFM cantilever stiffness: a microfabricated array of reflective springs
- 1 July 2004
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 22 (4) , 1444-1449
Microelectromechanical system device for calibration of atomic force microscope cantilever spring constants between 0.01 and 4 N/m
- 1 July 2004
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 22 (4) , 1444-1449
Microelectromechanical system device for calibration of atomic force microscope cantilever spring constants between 0.01 and 4 N/m
- 17 June 2004
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 15 (7) , 1337-1346
Quantitative analytical atomic force microscopy: a cantilever reference device for easy and accurate AFM spring-constant calibration
- 17 June 2004
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 15 (7) , 1337-1346
Quantitative analytical atomic force microscopy: a cantilever reference device for easy and accurate AFM spring-constant calibration