Robert T. Burks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Robert T. Burks has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Patrick E. Greis
Department of Orthopaedics, University of Utah, Salt Lake City, Utah
5 shared publications- Julia R. Crim
University of Missouri at Columbia
4 shared publications - James Derek Wylie
J. D. Wylie, Director of Orthopedic Research, Intermountain Healthcare, The Orthopedic Specialty Hospital, Murray, UT USA
3 shared publications - Patrick E. Greis
Department of Orthopaedics, University of Utah Orthopaedic Center, University of Utah, Salt Lake City, Utah, USA
3 shared publications Robert Z. Tashjian
University of Utah Orthopaedic Center Salt Lake City Utah U.S.A.
3 shared publications- Heath B. Henninger
Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States; Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, United States
2 shared publications
Latest Publications
- Open Access
- 20 August 2018
- Published by Wiley in Arthroscopy Techniques
- Vol. 7 (9) , E927-E937
Rotator Cuff Repair Technique With Transosseous Knotless Anchor System
Various surgical techniques exist for rotator cuff repair that provide a suitable environment for tendon–bone healing. Arthroscopic recreation of transosseous repairs, which had previously been performed by open or miniopen techniques, can now be performed; however, arthroscopic, transosseous passage of suture material can be challenging technically. There are potential biologic and cost‐saving advantages of arthroscopic transosseous rotator cuff repair that make an efficient and reproducible technique desirable for arthroscopists. The technique for arthroscopic transosseous rotator cuff repair using a knotless anchor‐based system is demonstrated in the current Technical Note. Potential advantages of this construct include excellent biomechanics, enhanced footprint vascularization, and utility in poor bone quality while using minimal anchor numbers. Further studies will be needed to elucidate healing rates and clinical outcomes. Technique Video: video See video under supplementary data.
- 20 August 2018
- Published by Wiley in Arthroscopy Techniques
- Vol. 7 (9) , E927-E937
Open AccessRotator Cuff Repair Technique With Transosseous Knotless Anchor System
Various surgical techniques exist for rotator cuff repair that provide a suitable environment for tendon–bone healing. Arthroscopic recreation of transosseous repairs, which had previously been performed by open or miniopen techniques, can now be performed; however, arthroscopic, transosseous passage of suture material can be challenging technically. There are potential biologic and cost‐saving advantages of arthroscopic transosseous rotator cuff repair that make an efficient and reproducible technique desirable for arthroscopists. The technique for arthroscopic transosseous rotator cuff repair using a knotless anchor‐based system is demonstrated in the current Technical Note. Potential advantages of this construct include excellent biomechanics, enhanced footprint vascularization, and utility in poor bone quality while using minimal anchor numbers. Further studies will be needed to elucidate healing rates and clinical outcomes. Technique Video: video See video under supplementary data.
- 1 May 2017
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 26 (5) , e155
Factors influencing direct clinical costs of outpatient arthroscopic rotator cuff repair surgery
- 1 May 2017
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 26 (5) , e155
Factors influencing direct clinical costs of outpatient arthroscopic rotator cuff repair surgery
- 1 January 2017
- Published by Elsevier in Clinics in Sports Medicine
- Vol. 36 (1) , 155-172
Etiologic Factors That Lead to Failure After Primary Anterior Cruciate Ligament Surgery
- 1 January 2017
- Published by Elsevier in Clinics in Sports Medicine
- Vol. 36 (1) , 155-172
Etiologic Factors That Lead to Failure After Primary Anterior Cruciate Ligament Surgery
- 21 July 2016
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 44 (9) , 2225-2230
The Medial Stitch in Transosseous-Equivalent Rotator Cuff Repair
Despite advances in surgical technique, rotator cuff repair retears continue to occur at rates of 10%, 22%, and 57% for small, medium, and large tears, respectively. A common mode of failure in transosseous-equivalent rotator cuff repairs is tissue pullout of the medial mattress stitch. While the medial mattress stitch has been studied extensively, no studies have evaluated a vertical mattress pattern placed near the musculotendinous junction in comparison with a horizontal mattress pattern. Vertical mattress stitches will have higher load to failure and lower gapping compared with horizontal mattress stitches in a transosseous-equivalent rotator cuff repair. Controlled laboratory study. Double-row transosseous-equivalent rotator cuff repairs were performed in 9 pairs of human male cadaveric shoulders (mean age ± SD, 58 ± 10 years). One shoulder in each pair received a medial-row suture pattern using a vertical mattress stitch, and the contralateral shoulder received a horizontal mattress. Specimens were mounted in a materials testing machine and tested in uniaxial tensile deformation for cyclic loading (500 cycles at 1 Hz to 1.0 MPa of effective stress), followed by failure testing carried out at a rate of 1 mm/s. Construct gapping and applied loads were monitored continuously throughout the testing. Vertical mattress sutures were placed in 5 right and 4 left shoulders. Peak cyclic gapping did not differ between vertical (mean ± SD, 2.8 ± 1.1 mm) and horizontal mattress specimens (3.0 ± 1.2 mm) (P = .684). Vertical mattress sutures failed at higher loads compared with horizontal mattress sutures (568.9 ± 140.3 vs 451.1 ± 174.3 N; P = .025); however, there was no significant difference in failure displacement (8.0 ± 1.6 vs 6.0 ± 2.1 mm; P = .092). Failure stiffness did not differ between the suture patterns (P = .204). In transosseous-equivalent rotator cuff repairs near the musculotendinous junction, a vertical mattress suture used as the medial stitch has a higher load to failure but no difference in gapping compared with a horizontal mattress pattern. A vertical mattress suture may offer enhanced strength of repair for transosseous-equivalent repairs.
- 21 July 2016
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 44 (9) , 2225-2230
The Medial Stitch in Transosseous-Equivalent Rotator Cuff Repair
Despite advances in surgical technique, rotator cuff repair retears continue to occur at rates of 10%, 22%, and 57% for small, medium, and large tears, respectively. A common mode of failure in transosseous-equivalent rotator cuff repairs is tissue pullout of the medial mattress stitch. While the medial mattress stitch has been studied extensively, no studies have evaluated a vertical mattress pattern placed near the musculotendinous junction in comparison with a horizontal mattress pattern. Vertical mattress stitches will have higher load to failure and lower gapping compared with horizontal mattress stitches in a transosseous-equivalent rotator cuff repair. Controlled laboratory study. Double-row transosseous-equivalent rotator cuff repairs were performed in 9 pairs of human male cadaveric shoulders (mean age ± SD, 58 ± 10 years). One shoulder in each pair received a medial-row suture pattern using a vertical mattress stitch, and the contralateral shoulder received a horizontal mattress. Specimens were mounted in a materials testing machine and tested in uniaxial tensile deformation for cyclic loading (500 cycles at 1 Hz to 1.0 MPa of effective stress), followed by failure testing carried out at a rate of 1 mm/s. Construct gapping and applied loads were monitored continuously throughout the testing. Vertical mattress sutures were placed in 5 right and 4 left shoulders. Peak cyclic gapping did not differ between vertical (mean ± SD, 2.8 ± 1.1 mm) and horizontal mattress specimens (3.0 ± 1.2 mm) (P = .684). Vertical mattress sutures failed at higher loads compared with horizontal mattress sutures (568.9 ± 140.3 vs 451.1 ± 174.3 N; P = .025); however, there was no significant difference in failure displacement (8.0 ± 1.6 vs 6.0 ± 2.1 mm; P = .092). Failure stiffness did not differ between the suture patterns (P = .204). In transosseous-equivalent rotator cuff repairs near the musculotendinous junction, a vertical mattress suture used as the medial stitch has a higher load to failure but no difference in gapping compared with a horizontal mattress pattern. A vertical mattress suture may offer enhanced strength of repair for transosseous-equivalent repairs.
- 1 December 2015
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 27 (8) , 652-657
Local anesthetic injection deep to the fascia iliaca at the level of the inguinal ligament: the pattern of distribution and effects on the obturator nerve
- 1 December 2015
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 27 (8) , 652-657
Local anesthetic injection deep to the fascia iliaca at the level of the inguinal ligament: the pattern of distribution and effects on the obturator nerve
- 1 August 2015
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 24 (8) , e237
Psychological Distress Negatively Impacts Self-Assessment of Shoulder Function in Patients With Rotator Cuff Tears
- 1 August 2015
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 24 (8) , e237
Psychological Distress Negatively Impacts Self-Assessment of Shoulder Function in Patients With Rotator Cuff Tears
- 1 January 2015
- Published by Elsevier in Orthopedic Clinics of North America
- Vol. 46 (1) , 159-169
MPFL Reconstruction
- 1 January 2015
- Published by Elsevier in Orthopedic Clinics of North America
- Vol. 46 (1) , 159-169
MPFL Reconstruction
- 23 October 2014
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 43 (1) , 57-62
Suture Placement Near the Musculotendinous Junction in the Supraspinatus
Transosseous-equivalent rotator cuff repair has an increased incidence of medial rotator cuff failure compared with single-row repair. No studies have evaluated the influence of the proximity of the suture row to the musculotendinous junction (MTJ) on cyclic gapping and failure properties. A single row of horizontal mattress sutures placed within the supraspinatus tendon lateral to the MTJ will experience less gap formation and higher failure loads than a similar suture row placed at the MTJ. Controlled laboratory study. Paired supraspinatus tendons were isolated from human cadaveric specimens and resected at the tendon insertion to the humerus. Randomized within a pair, a single row of 4 horizontal mattress sutures was placed either in the tendon 5 mm lateral to the MTJ or at the MTJ. The tied sutures secured the tendon to a fixture that ensured consistent placement of the suture row in the tendon and static fixation of the row. The muscle belly was gripped in a cryoclamp, and a servohydraulic materials testing machine was used to provide uniaxial tensile deformation for 500 cycles at 1 Hz, followed by load to failure at 1 mm/s. Fiducial markers with video tracking were used to quantify gap formation at the suture line, while the materials testing machine recorded loading for the cyclic and failure tests. During cyclic loading, both constructs experienced gross initial gap formation, followed by progressive gap formation that plateaued after cycle 200. The MTJ specimens had significantly higher mean cumulative gapping than the tendon specimens: 3.6 ± 1.0 mm versus 2.4 ± 0.6 mm, respectively (P = .012). The tendon specimens had significantly higher mean loads to failure than did the MTJ specimens: 567.1 ± 121.8 N versus 434.2 ± 148.1 N, respectively (P = .013). The mean failure displacement did not differ between groups for the tendon and MTJ: 5.7 ± 2.5 mm versus 4.5 ± 2.0 mm, respectively (P = .144). A horizontal suture row placed at the MTJ has inferior mechanical properties (increased gapping, decreased load support) as compared with a suture row placed 5 mm laterally within the tendon. The integrity of rotator cuff repair may be compromised if sutures are placed too close to the MTJ.
- 23 October 2014
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 43 (1) , 57-62
Suture Placement Near the Musculotendinous Junction in the Supraspinatus
Transosseous-equivalent rotator cuff repair has an increased incidence of medial rotator cuff failure compared with single-row repair. No studies have evaluated the influence of the proximity of the suture row to the musculotendinous junction (MTJ) on cyclic gapping and failure properties. A single row of horizontal mattress sutures placed within the supraspinatus tendon lateral to the MTJ will experience less gap formation and higher failure loads than a similar suture row placed at the MTJ. Controlled laboratory study. Paired supraspinatus tendons were isolated from human cadaveric specimens and resected at the tendon insertion to the humerus. Randomized within a pair, a single row of 4 horizontal mattress sutures was placed either in the tendon 5 mm lateral to the MTJ or at the MTJ. The tied sutures secured the tendon to a fixture that ensured consistent placement of the suture row in the tendon and static fixation of the row. The muscle belly was gripped in a cryoclamp, and a servohydraulic materials testing machine was used to provide uniaxial tensile deformation for 500 cycles at 1 Hz, followed by load to failure at 1 mm/s. Fiducial markers with video tracking were used to quantify gap formation at the suture line, while the materials testing machine recorded loading for the cyclic and failure tests. During cyclic loading, both constructs experienced gross initial gap formation, followed by progressive gap formation that plateaued after cycle 200. The MTJ specimens had significantly higher mean cumulative gapping than the tendon specimens: 3.6 ± 1.0 mm versus 2.4 ± 0.6 mm, respectively (P = .012). The tendon specimens had significantly higher mean loads to failure than did the MTJ specimens: 567.1 ± 121.8 N versus 434.2 ± 148.1 N, respectively (P = .013). The mean failure displacement did not differ between groups for the tendon and MTJ: 5.7 ± 2.5 mm versus 4.5 ± 2.0 mm, respectively (P = .144). A horizontal suture row placed at the MTJ has inferior mechanical properties (increased gapping, decreased load support) as compared with a suture row placed 5 mm laterally within the tendon. The integrity of rotator cuff repair may be compromised if sutures are placed too close to the MTJ.
- 23 July 2014
- Published by Wiley in Arthroscopy
- Vol. 30 (10) , 1246-1253
An Analysis of Technical Aspects of the Arthroscopic Bankart Procedure as Performed in the United States
Purpose: The purpose of this study was to investigate the intersurgeon variation in technical aspects of performing an arthroscopic Bankart repair. Methods: A unique approach with experienced equipment representatives from 3 different arthroscopic companies was used. Experienced representatives were identified by DePuy Mitek, Smith & Nephew, and Arthrex and filled out questionnaires on how their surgeons performed arthroscopic Bankart procedures. This was performed in a blinded fashion with no knowledge of the identities of the specific surgeons or representatives by us. A video on different aspects of the procedure was observed by each representative before filling out the questionnaire to help standardize responses. Data were collected using REDCap (Research Electronic Data Capture). Data were analyzed as an infrequent observation with 0% to 30% of representatives reporting the observation; sometimes, 31% to 70% reporting the observation; and often, greater than 70% of representatives reporting. Results: Seventy‐six percent of representatives had 6 or more years of arthroscopic experience. Forty‐three percent of representatives reported that their surgeons use 3 portals for the procedure often. Forty‐four percent reported that viewing was performed exclusively from the posterior portal while the surgeon was performing the repair. Seventy‐three percent reported that the Hill‐Sachs lesion was observed often, and 61% reported that the posterior labrum was evaluated often before the repair. Only 25% of representatives reported that the Bankart lesion was extensively released and mobilized often. Thirty‐three percent reported 3 anchors as being used often. Seventy‐five percent reported biocomposite anchors as being used often. Single‐loaded anchors were reported as being used often by 47%. Eighty‐one percent reported that sutures were placed in a simple fashion. Eighty‐three percent reported the use of any posterior sutures or anchors for additional plication as infrequent. Conclusions: There is significant variation in performance of the arthroscopic Bankart repair in the United States. Areas of concern include completeness of the diagnostic examination, the adequacy of capsulolabral mobilization, variation in the use of accessory portals, and inconsistent use of additional capsular or labral plication or fixation.
- 23 July 2014
- Published by Wiley in Arthroscopy
- Vol. 30 (10) , 1246-1253
An Analysis of Technical Aspects of the Arthroscopic Bankart Procedure as Performed in the United States
Purpose: The purpose of this study was to investigate the intersurgeon variation in technical aspects of performing an arthroscopic Bankart repair. Methods: A unique approach with experienced equipment representatives from 3 different arthroscopic companies was used. Experienced representatives were identified by DePuy Mitek, Smith & Nephew, and Arthrex and filled out questionnaires on how their surgeons performed arthroscopic Bankart procedures. This was performed in a blinded fashion with no knowledge of the identities of the specific surgeons or representatives by us. A video on different aspects of the procedure was observed by each representative before filling out the questionnaire to help standardize responses. Data were collected using REDCap (Research Electronic Data Capture). Data were analyzed as an infrequent observation with 0% to 30% of representatives reporting the observation; sometimes, 31% to 70% reporting the observation; and often, greater than 70% of representatives reporting. Results: Seventy‐six percent of representatives had 6 or more years of arthroscopic experience. Forty‐three percent of representatives reported that their surgeons use 3 portals for the procedure often. Forty‐four percent reported that viewing was performed exclusively from the posterior portal while the surgeon was performing the repair. Seventy‐three percent reported that the Hill‐Sachs lesion was observed often, and 61% reported that the posterior labrum was evaluated often before the repair. Only 25% of representatives reported that the Bankart lesion was extensively released and mobilized often. Thirty‐three percent reported 3 anchors as being used often. Seventy‐five percent reported biocomposite anchors as being used often. Single‐loaded anchors were reported as being used often by 47%. Eighty‐one percent reported that sutures were placed in a simple fashion. Eighty‐three percent reported the use of any posterior sutures or anchors for additional plication as infrequent. Conclusions: There is significant variation in performance of the arthroscopic Bankart repair in the United States. Areas of concern include completeness of the diagnostic examination, the adequacy of capsulolabral mobilization, variation in the use of accessory portals, and inconsistent use of additional capsular or labral plication or fixation.
- 1 July 2014
- Published by Elsevier in Clinics in Sports Medicine
- Vol. 33 (3) , 501-516
MPFL Reconstruction
- 1 July 2014
- Published by Elsevier in Clinics in Sports Medicine
- Vol. 33 (3) , 501-516
MPFL Reconstruction