Carolyn Cidis Meltzer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Carolyn Cidis Meltzer has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Julie C. Price
Department of Radiology, University of Pittsburgh, Pittsburgh, PA, USA
5 shared publications - Phil J. Greer
Ariel Precision Medicine Pittsburgh Pennsylvania
5 shared publications Brian Lopresti
3 shared publicationsCharles F. Reynolds
3 shared publicationsChester A. Mathis
3 shared publicationsJulie C. Price
3 shared publications
Latest Publications
- 31 December 2008
- Published by Elsevier in NeuroImage
- Vol. 41, T155
Altered 5-HT1A and 5-HT2A receptor interactions in anorexia and bulimia nervosa
- 31 December 2008
- Published by Elsevier in NeuroImage
- Vol. 41, T155
Altered 5-HT1A and 5-HT2A receptor interactions in anorexia and bulimia nervosa
- 31 December 2008
- Published by Elsevier in NeuroImage
- Vol. 41, T47-47
Prefrontal 5-HT2A density predicts amygdala reactivity
- 31 December 2008
- Published by Elsevier in NeuroImage
- Vol. 41, T47-47
Prefrontal 5-HT2A density predicts amygdala reactivity
- 31 December 2008
- Published by Elsevier in NeuroImage
- Vol. 41, T121
Possible relationship of serotonin transporter to dopamine D2/D3 receptor binding after recovery from eating disorders
- 31 December 2008
- Published by Elsevier in NeuroImage
- Vol. 41, T121
Possible relationship of serotonin transporter to dopamine D2/D3 receptor binding after recovery from eating disorders
- 29 October 2002
- Vol. 35 (8) , 767-77
[Neuropharmacology and receptor studies in the elderly].
Functional brain imaging has provided unique and exciting opportunities to strengthen our knowledge of the biological substrate of the aging brain and neuropsychiatric disorders. Positron emission tomography (PET) is a particularly powerful tool for quantifying the neurobiological correlates of cognition, mood and behavior. Initial PET studies of aging, psychiatric disorders and neurodegenerative disease focused primarily on generalized physiological parameters such as cerebral blood flow and metabolism, and early neuroreceptor imaging studies relied on relatively non selective markers. New, selective receptor radioligands now offer a previously inaccessible means to investigate the dynamic relationships among neurochemistry, aging and psychopathology in vivo. This approach has substantial advantages over peripheral (platelet and cerebrospinal fluid) markers, neuroendocrine challenge studies, animal models, and postmortem receptor binding assays. Advances in tracer kinetic modeling, magnetic resonance imaging (MRI) to PET registration, radiochemistry techniques, instrumentation and image processing have helped pave the way for increased emphasis on functional imaging studies of neuropsychiatric disorders of the elderly. The capability to correct PET image data for the confounding effect of cerebral atrophy permits relationships among age related brain changes and neurobiological disease mechanisms to be more accurately examined in the course of normal aging and in elderly patient populations.
- 29 October 2002
- Vol. 35 (8) , 767-77
[Neuropharmacology and receptor studies in the elderly].
Functional brain imaging has provided unique and exciting opportunities to strengthen our knowledge of the biological substrate of the aging brain and neuropsychiatric disorders. Positron emission tomography (PET) is a particularly powerful tool for quantifying the neurobiological correlates of cognition, mood and behavior. Initial PET studies of aging, psychiatric disorders and neurodegenerative disease focused primarily on generalized physiological parameters such as cerebral blood flow and metabolism, and early neuroreceptor imaging studies relied on relatively non selective markers. New, selective receptor radioligands now offer a previously inaccessible means to investigate the dynamic relationships among neurochemistry, aging and psychopathology in vivo. This approach has substantial advantages over peripheral (platelet and cerebrospinal fluid) markers, neuroendocrine challenge studies, animal models, and postmortem receptor binding assays. Advances in tracer kinetic modeling, magnetic resonance imaging (MRI) to PET registration, radiochemistry techniques, instrumentation and image processing have helped pave the way for increased emphasis on functional imaging studies of neuropsychiatric disorders of the elderly. The capability to correct PET image data for the confounding effect of cerebral atrophy permits relationships among age related brain changes and neurobiological disease mechanisms to be more accurately examined in the course of normal aging and in elderly patient populations.
- 1 March 2001
- Published by Elsevier in Brain Research
- Vol. 895 (1-2) , 9-17
Gender-specific aging effects on the serotonin 1A receptor
- 1 March 2001
- Published by Elsevier in Brain Research
- Vol. 895 (1-2) , 9-17
Gender-specific aging effects on the serotonin 1A receptor
- 1 November 2000
- Vol. 41 (11) , 1842-8
Does cerebral blood flow decline in healthy aging? A PET study with partial-volume correction.
It remains a matter of controversy as to whether cerebral perfusion declines with healthy aging. In vivo imaging with PET permits quantitative evaluation of brain physiology; however, previous PET studies have inconsistently reported aging reductions in cerebral blood flow (CBF), oxygen metabolism, and glucose metabolism. In part, this may be because of a lack of correction for the dilution effect of age-related cerebral volume loss on PET measurements. CBF PET scans were obtained using [15O]H2O in 27 healthy individuals (age range, 19-76 y) and corrected for partial-volume effects from cerebral atrophy using an MR-based algorithm. There was a significant difference (P = 0.01) in mean cortical CBF between young/midlife (age range, 19-46 y; mean +/- SD, 56+/-10 mL/100 mL/min) and elderly (age range, 60-76 y; mean +/- SD, 49+/-2.6 mL/100 mL/min) subgroups before correcting for partial-volume effects. However, this group difference resolved after partial-volume correction (young/midlife: mean +/- SD, 62+/-10 mL/100 mL/min; elderly: mean +/- SD, 61+/-4.8 mL/100 mL/min; P = 0.66). When all subjects were considered, a mild but significant inverse correlation between age and cortical CBF measurements was present in the uncorrected but not the corrected data. This study suggests that CBF may not decline with age in healthy individuals and that failure to correct for the dilution effect of age-related cerebral atrophy may confound interpretation of previous PET studies that have shown aging reductions in physiologic measurements.
- 1 November 2000
- Vol. 41 (11) , 1842-8
Does cerebral blood flow decline in healthy aging? A PET study with partial-volume correction.
It remains a matter of controversy as to whether cerebral perfusion declines with healthy aging. In vivo imaging with PET permits quantitative evaluation of brain physiology; however, previous PET studies have inconsistently reported aging reductions in cerebral blood flow (CBF), oxygen metabolism, and glucose metabolism. In part, this may be because of a lack of correction for the dilution effect of age-related cerebral volume loss on PET measurements. CBF PET scans were obtained using [15O]H2O in 27 healthy individuals (age range, 19-76 y) and corrected for partial-volume effects from cerebral atrophy using an MR-based algorithm. There was a significant difference (P = 0.01) in mean cortical CBF between young/midlife (age range, 19-46 y; mean +/- SD, 56+/-10 mL/100 mL/min) and elderly (age range, 60-76 y; mean +/- SD, 49+/-2.6 mL/100 mL/min) subgroups before correcting for partial-volume effects. However, this group difference resolved after partial-volume correction (young/midlife: mean +/- SD, 62+/-10 mL/100 mL/min; elderly: mean +/- SD, 61+/-4.8 mL/100 mL/min; P = 0.66). When all subjects were considered, a mild but significant inverse correlation between age and cortical CBF measurements was present in the uncorrected but not the corrected data. This study suggests that CBF may not decline with age in healthy individuals and that failure to correct for the dilution effect of age-related cerebral atrophy may confound interpretation of previous PET studies that have shown aging reductions in physiologic measurements.
- 1 November 2000
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 25 (11) , 882-887
Whole-Body FDG Positron Emission Tomographic Imaging for Staging Esophageal Cancer
The aim of the authors in this study was to critically evaluate the role of whole-body positron emission tomographic (PET) imaging with fluorine-18 fluorodeoxyglucose (FDG) in staging esophageal cancer, and further to compare this method with conventional imaging with computed tomography (CT). The authors performed independent, blinded retrospective evaluations of FDG PET images obtained in 47 patients referred for the initial staging of esophageal cancer before minimally invasive surgical staging. Twenty PET studies from patients with nonesophageal thoracic cancers were randomly selected for inclusion in the PET readings. In a subset of 37 of 47 cases, the PET findings were compared with independent readings of CT studies acquired within the same 6-week interval. The utility of the imaging findings was evaluated using a high-sensitivity interpretation (i.e., assigning equivocal findings as positive) and a low-sensitivity interpretation (i.e., assigning equivocal findings as negative). PET was less sensitive (41% in high-sensitivity mode, 35% in low-sensitivity mode) than CT (63% to 87%) for diagnosing tumor involvement in locoregional lymph nodes, which was identified by surgical assessment in 72% of patients. Notable, however, was the greater specificity of PET-determined nodal sites (to approximately 90%) compared with CT (14% to 43%). In detecting histologically proved distant metastases (n = 10), PET performed considerably better when applied in the high-sensitivity mode, with a sensitivity rate of approximately 70% and a specificity rate of more than 90% in the total group and in the subset of patients with correlative CT data. In the low-sensitivity mode, CT identified only two of seven metastatic sites, whereas the high-sensitivity mode resulted in an unacceptably high rate of false-positive readings (positive predictive value, 29%). PET correctly identified one additional site of metastasis that was not detected by CT. The relatively low sensitivity of PET for identifying locoregional lesions precludes its replacement of conventional CT staging. However, the primary advantage of PET imaging is its superior specificity for tumor detection and improved diagnostic value for distant metastatic sites, features that may substantially affect patient management decisions. In conclusion, PET imaging is useful in the initial staging of esophageal cancer and provides additional and complementary information to that obtained by CT imaging.
- 1 November 2000
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 25 (11) , 882-887
Whole-Body FDG Positron Emission Tomographic Imaging for Staging Esophageal Cancer
The aim of the authors in this study was to critically evaluate the role of whole-body positron emission tomographic (PET) imaging with fluorine-18 fluorodeoxyglucose (FDG) in staging esophageal cancer, and further to compare this method with conventional imaging with computed tomography (CT). The authors performed independent, blinded retrospective evaluations of FDG PET images obtained in 47 patients referred for the initial staging of esophageal cancer before minimally invasive surgical staging. Twenty PET studies from patients with nonesophageal thoracic cancers were randomly selected for inclusion in the PET readings. In a subset of 37 of 47 cases, the PET findings were compared with independent readings of CT studies acquired within the same 6-week interval. The utility of the imaging findings was evaluated using a high-sensitivity interpretation (i.e., assigning equivocal findings as positive) and a low-sensitivity interpretation (i.e., assigning equivocal findings as negative). PET was less sensitive (41% in high-sensitivity mode, 35% in low-sensitivity mode) than CT (63% to 87%) for diagnosing tumor involvement in locoregional lymph nodes, which was identified by surgical assessment in 72% of patients. Notable, however, was the greater specificity of PET-determined nodal sites (to approximately 90%) compared with CT (14% to 43%). In detecting histologically proved distant metastases (n = 10), PET performed considerably better when applied in the high-sensitivity mode, with a sensitivity rate of approximately 70% and a specificity rate of more than 90% in the total group and in the subset of patients with correlative CT data. In the low-sensitivity mode, CT identified only two of seven metastatic sites, whereas the high-sensitivity mode resulted in an unacceptably high rate of false-positive readings (positive predictive value, 29%). PET correctly identified one additional site of metastasis that was not detected by CT. The relatively low sensitivity of PET for identifying locoregional lesions precludes its replacement of conventional CT staging. However, the primary advantage of PET imaging is its superior specificity for tumor detection and improved diagnostic value for distant metastatic sites, features that may substantially affect patient management decisions. In conclusion, PET imaging is useful in the initial staging of esophageal cancer and provides additional and complementary information to that obtained by CT imaging.
Planned Ictal FDG PET Imaging for Localization of Extratemporal Epileptic Foci
Summary: Purpose: This work demonstrates the feasibility of planned ictal positron emission tomography (PET) with [18F]fluoro‐2‐deoxy‐glucose (FDG) for localization of epileptic activity in patients with frequent partial seizures of extratem‐poral origin. Methods: Ictal PET imaging was performed in four patients (two men and two women, ages 28–61) with continuous or very frequent (every 3–15 min) partial seizures. All patients had abnormalities apparent on magnetic resonance (MR) or computed tomographic (CT) imaging, two with extensive brain lesions that precluded precise localization of the seizure focus with interictal PET or single‐photon emission tomography (SPECT) imaging. Results: Ictal PET imaging demonstrated a restricted area of focal hypermetabolism concordant with surface electroen‐cephalographic (EEG) recording in all cases. The PET images were registered to MR imaging data for further anatomic localization of hypermetabolic regions in three cases. The ictal PET data were used to guide neurosurgical intervention in one case. Conclusions: We conclude that planned ictal PET imaging may be a useful and potentially superior approach to ictal SPECT for identifying the epileptic focus in a selected group of patients with continuous or frequent simple partial seizures.
Planned Ictal FDG PET Imaging for Localization of Extratemporal Epileptic Foci
Summary: Purpose: This work demonstrates the feasibility of planned ictal positron emission tomography (PET) with [18F]fluoro‐2‐deoxy‐glucose (FDG) for localization of epileptic activity in patients with frequent partial seizures of extratem‐poral origin. Methods: Ictal PET imaging was performed in four patients (two men and two women, ages 28–61) with continuous or very frequent (every 3–15 min) partial seizures. All patients had abnormalities apparent on magnetic resonance (MR) or computed tomographic (CT) imaging, two with extensive brain lesions that precluded precise localization of the seizure focus with interictal PET or single‐photon emission tomography (SPECT) imaging. Results: Ictal PET imaging demonstrated a restricted area of focal hypermetabolism concordant with surface electroen‐cephalographic (EEG) recording in all cases. The PET images were registered to MR imaging data for further anatomic localization of hypermetabolic regions in three cases. The ictal PET data were used to guide neurosurgical intervention in one case. Conclusions: We conclude that planned ictal PET imaging may be a useful and potentially superior approach to ictal SPECT for identifying the epileptic focus in a selected group of patients with continuous or frequent simple partial seizures.
- 1 December 1999
- Published by American Psychiatric Association Publishing in American Journal of Psychiatry
- Vol. 156 (12) , 1871-1878
PET Imaging of Serotonin Type 2A Receptors in Late-Life Neuropsychiatric Disorders
OBJECTIVE: To determine whether there are abnormalities in the in vivo status of the serotonin type 2A (5-HT2A) receptor in late-life depression and Alzheimer’s disease, the authors used positron emission tomography (PET) to assess patients with these two conditions and healthy subjects. METHOD: PET was performed by using [18F]altanserin to evaluate 5-HT2A receptor binding in 11 elderly patients with depression (four men, seven women; mean age=65.0 years, SD=5.5); nine Alzheimer’s disease patients, including three with concurrent depression (two men, seven women; mean age=69.7 years, SD=5.0); and 10 age-matched healthy subjects (four men, six women; mean age=69.8 years, SD=5.0). Partial-volume correction of regional specific binding estimates was performed by using a method based on magnetic resonance imaging. RESULTS: No significant abnormalities in [18F]altanserin binding (binding potential) were observed in the patients with late-life depression, and no effect of depression on binding potential was present within the Alzheimer’s disease group. However, the patients with Alzheimer’s disease had significantly lower binding than the normal subjects in several brain regions, including the anterior cingulate, prefrontal cortex, and sensorimotor cortex. CONCLUSIONS: These results suggest that the 5-HT2A receptor is differentially affected in late-life depression and Alzheimer’s disease, a finding that has implications for the etiological basis of mood and cognitive features of neuropsychiatric disorders of late life.
- 1 December 1999
- Published by American Psychiatric Association Publishing in American Journal of Psychiatry
- Vol. 156 (12) , 1871-1878
PET Imaging of Serotonin Type 2A Receptors in Late-Life Neuropsychiatric Disorders
OBJECTIVE: To determine whether there are abnormalities in the in vivo status of the serotonin type 2A (5-HT2A) receptor in late-life depression and Alzheimer’s disease, the authors used positron emission tomography (PET) to assess patients with these two conditions and healthy subjects. METHOD: PET was performed by using [18F]altanserin to evaluate 5-HT2A receptor binding in 11 elderly patients with depression (four men, seven women; mean age=65.0 years, SD=5.5); nine Alzheimer’s disease patients, including three with concurrent depression (two men, seven women; mean age=69.7 years, SD=5.0); and 10 age-matched healthy subjects (four men, six women; mean age=69.8 years, SD=5.0). Partial-volume correction of regional specific binding estimates was performed by using a method based on magnetic resonance imaging. RESULTS: No significant abnormalities in [18F]altanserin binding (binding potential) were observed in the patients with late-life depression, and no effect of depression on binding potential was present within the Alzheimer’s disease group. However, the patients with Alzheimer’s disease had significantly lower binding than the normal subjects in several brain regions, including the anterior cingulate, prefrontal cortex, and sensorimotor cortex. CONCLUSIONS: These results suggest that the 5-HT2A receptor is differentially affected in late-life depression and Alzheimer’s disease, a finding that has implications for the etiological basis of mood and cognitive features of neuropsychiatric disorders of late life.
- 1 December 1999
- Vol. 40 (12) , 2053-65
Comparative evaluation of MR-based partial-volume correction schemes for PET.
Because of limitations of spatial resolution, quantitative PET measurements of cerebral blood flow, glucose metabolism and neuroreceptor binding are influenced by partial-volume averaging among neighboring tissues with differing tracer concentrations. Two MR-based approaches to partial-volume correction of PET images were compared using simulations and a multicompartment phantom. The two-compartment method corrects PET data for the diluting effects of cerebrospinal fluid (CSF) spaces. The more complex three-compartment method also accounts for the effect of partial-volume averaging between gray and white matter. The effects of the most significant sources of error on MR-based partial-volume correction, including misregistration, resolution mismatch, segmentation errors and white matter heterogeneity, were evaluated. We also examined the relative usefulness of both approaches in PET studies of aging and neurodegenerative disease. Although the three-compartment method was highly accurate (with 100% gray matter recovery achieved in simulations), it was also more sensitive to all errors tested, particularly image segmentation and PET-MR registration. Based on these data, we conclude that the two-compartment approach is better suited for comparative PET studies, whereas the three-compartment algorithm is capable of greater accuracy for absolute quantitative measures.
- 1 December 1999
- Vol. 40 (12) , 2053-65
Comparative evaluation of MR-based partial-volume correction schemes for PET.
Because of limitations of spatial resolution, quantitative PET measurements of cerebral blood flow, glucose metabolism and neuroreceptor binding are influenced by partial-volume averaging among neighboring tissues with differing tracer concentrations. Two MR-based approaches to partial-volume correction of PET images were compared using simulations and a multicompartment phantom. The two-compartment method corrects PET data for the diluting effects of cerebrospinal fluid (CSF) spaces. The more complex three-compartment method also accounts for the effect of partial-volume averaging between gray and white matter. The effects of the most significant sources of error on MR-based partial-volume correction, including misregistration, resolution mismatch, segmentation errors and white matter heterogeneity, were evaluated. We also examined the relative usefulness of both approaches in PET studies of aging and neurodegenerative disease. Although the three-compartment method was highly accurate (with 100% gray matter recovery achieved in simulations), it was also more sensitive to all errors tested, particularly image segmentation and PET-MR registration. Based on these data, we conclude that the two-compartment approach is better suited for comparative PET studies, whereas the three-compartment algorithm is capable of greater accuracy for absolute quantitative measures.