RSRichard A. Schwarz

Richard A. Schwarz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Richard A. Schwarz has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimization of a mobile imaging system to aid in evaluating patients with oral lesions in a dental care setting

    by Ruchika Mitbander, Jennifer Carns, Richard A. Schwarz, Sean Anderson, Geethanjali Vipulanandan, Miriam Hernandez, Amelia E. Hartzell, Jun Jiao, Ilona Rutkowska, Safia Durab, et al.

    SignificanceOral cancer is often diagnosed at an advanced stage even though the oral cavity is easily accessible for examination. There is a need for tools to support early detection and help non-expert clinicians make appropriate referral recommendations.AimWe aim to evaluate a mobile detection of oral cancer (mDOC) smartphone-based autofluorescence imaging system by collecting data in a representative, low-prevalence population and optimizing a referral algorithm suitable for deployment in community dental settings.ApproachData were collected from patients at a community dental clinic using the mDOC system, which captures white light and autofluorescence images. A multi-input deep learning algorithm was developed using both previously acquired and newly collected data in a rehearsal training method. Performance was evaluated on training, validation, and test sets using expert referral decision as the ground truth. Metrics included the Brier Skill Score, area under the ROC curve (AUC-ROC), sensitivity, and specificity.ResultsData from 252 anatomic sites across 50 patients were collected, with five sites in four patients referred to an oral cancer specialist based on expert review. The best-performing algorithm achieved a Brier Skill Score of 0.126. It reached an AUC-ROC of 0.986 on the validation set and an AUC-ROC of 0.778 on the test set. Sensitivity and specificity on the test set were 60.0% and 88.0%, respectively.ConclusionsThese findings demonstrate the potential of the mDOC system and referral algorithm to assist in early detection and triage of oral mucosal lesions in low-prevalence, community dental clinic settings.


  • Open Access

    Design and Evaluation of ScanCap: A Low-Cost, Reusable Tethered Capsule Endoscope with Blue-Green Illumination Imaging for Unsedated Screening and Early Detection of Barrett’s Esophagus

    by Cheima Hicheri, Ahad M. Azimuddin, Alex Kortum, Joseph Bailey, Yubo Tang, Richard A. Schwarz, Daniel Rosen, Shilpa Jain, Nabil M. Mansour, Shawn Groth, et al.

    Esophageal carcinoma is the sixth-leading cause of cancer death worldwide. A precursor to esophageal adenocarcinoma (EAC) is Barrett’s Esophagus (BE). Early-stage diagnosis and treatment of esophageal neoplasia (Barrett’s with high-grade dysplasia/intramucosal cancer) increase the five-year survival rate from 10% to 98%. BE is a global challenge; however, current endoscopes for early BE detection are costly and require extensive infrastructure for patient examination and sedation. We describe the design and evaluation of the first prototype of ScanCap, a high-resolution optical endoscopy system with a reusable, low-cost tethered capsule, designed to provide high-definition, blue-green illumination imaging for the early detection of BE in unsedated patients. The tethered capsule (12.8 mm diameter, 35.5 mm length) contains a color camera and rotating mirror and is designed to be swallowed; images are collected as the capsule is retracted manually via the tether. The tether provides electrical power and illumination at wavelengths of 415 nm and 565 nm and transmits data from the camera to a tablet. The ScanCap prototype capsule was used to image the oral mucosa in normal volunteers and ex vivo esophageal resections; images were compared to those obtained using an Olympus CV-180 endoscope. Images of superficial capillaries in intact oral mucosa were clearly visible in ScanCap images. Diagnostically relevant features of BE, including irregular Z-lines, distorted mucosa, and dilated vasculature, were clearly visible in ScanCap images of ex vivo esophageal specimens.


  • Open Access

    Use of topical methylene blue to image nuclear morphometry with a low-cost scanning darkfield microendoscope

    by Huayu Hou, Jennifer Carns, Richard A. Schwarz, Ann M. Gillenwater, Sharmila Anandasabapathy, Rebecca R. Richards-Kortum

    SignificanceFiber-optic microendoscopy is a promising approach to noninvasively visualize epithelial nuclear morphometry for early cancer and precancer detection. However, the broader clinical application of this approach is limited by a lack of topical contrast agents available for in vivo use.AimThe aim of this study was to evaluate the ability to image nuclear morphometry in vivo with a novel fiber-optic microendoscope used together with topical application of methylene blue (MB), a dye with FDA approval for use in chromoendoscopy in the gastrointestinal tract.ApproachThe low-cost, high-resolution microendoscope implements scanning darkfield imaging without complex optomechanical components by leveraging programmable illumination and the rolling shutter of the image sensor. We validate the integration of our system and MB staining for visualizing epithelial cell nuclei by performing ex vivo imaging on fresh animal specimens and in vivo imaging on healthy volunteers.ResultsThe results indicate that scanning darkfield imaging significantly reduces specular reflection and resolves epithelial nuclei with enhanced image contrast and spatial resolution compared to non-scanning widefield imaging. The image quality of darkfield images with MB staining is comparable to that of fluorescence images with proflavine staining.ConclusionsOur approach enables real-time microscopic evaluation of nuclear patterns and has the potential to be a powerful noninvasive tool for early cancer detection.


  • Initial Results of First In Vivo Imaging of Bladder Lesions Using a High-Resolution Confocal Microendoscope

    by Yubo Tang, Alex Kortum, Imran Vohra, Richard A. Schwarz, Jennifer Carns, Christopher R. Kannady, Jonathan Clavell-Hernandez, Zhihong Hu, Nadeem N Dhanani, Rebecca Richards-Kortum

    Purpose: Conventional cystoscopy plays an important role in detection of bladder cancer; however, it is difficult to differentiate benign and neoplastic lesions based on cystoscopic appearance alone. Advanced microscopic modalities, such as confocal laser endomicroscopy and optical coherence tomography, have been shown to provide critical histopathologic information to help identify neoplastic bladder lesions in real time, but their availability and clinical adoption are limited due to a high cost. In this study, we present the first use of a novel and low-cost ($ in vivo imaging of bladder lesions. Materials and Methods: In a cohort of 15 patients undergoing white light cystoscopy as part of their standard of care, high-resolution images of proflavine-stained bladder lesions were acquired in vivo using the confocal HRME. Based on these images, we evaluated the ability of the confocal HRME to visualize uroepithelium with subcellular resolution and high contrast. Furthermore, we analyzed the cellular architecture and staining patterns of benign and neoplastic bladder lesions in confocal HRME images and compared results to that of standard cystoscopy and histopathology. Results: In vivo imaging in the pilot study demonstrates that the confocal HRME resolved subcellular structures of bladder uroepithelium with high contrast. In a wide range of clinical conditions from normal bladder wall to benign and neoplastic lesions, confocal HRME images revealed important diagnostic features that correlated to histopathology. Conclusions: The confocal HRME provides an affordable, portable, and easy-to-use tool to allow real-time and high-contrast subcellular characterization of bladder lesions, well suited for bladder cancer detection in community and resource-constrained settings. The ClinicalTrials.gov Identifier: NCT02340650.


  • Open Access

    Algorithm to quantify nuclear features and confidence intervals for classification of oral neoplasia from high-resolution optical images

    by Eric C. Yang, David R. Brenes, Imran S. Vohra, Richard A. Schwarz, Michelle D. Williams, Nadarajah Vigneswaran, Ann M. Gillenwater, Rebecca R. Richards-Kortum

    In recent years, in vivo optical microscopy devices that visualize subcellular tissue features have been utilized to distinguish cancerous and precancerous tissue from benign tissue at a diverse range of anatomic sites.1 – 4 Compared to traditional tissue biopsies and histopathologic analysis, these devices are noninvasive and provide real-time results. Their potential application spans the spectrum of cancer care, from the diagnosis and surveillance of premalignant lesions, to margin delineation during surgical resections, and monitoring patients following treatment for recurrence.


  • 235 Accuracy of Post-Hoc High-Resolution Microendoscopy for Diagnosis of Esophageal Squamous Cell Neoplasia

    by Mimi C. Tan, Timothy Quang, Kalpesh K. Patel, Richard A. Schwarz, Chin Hur, Fan Zhang, Yu Xinying, Jason K. Hou, Mohamed O. Othman, Lubin F. Arevalo, et al.

  • Low-cost, portable imaging systems for cancer detection

    by Mark C. Pierce, Richard A. Schwarz, Dong-Suk Shin, Darren Roblyer, Tim Muldoon, Mohammed Rahman, Ann M. Gillenwater, Sharmila Anandasabapathy, Rebecca Richards-Kortum

    Worldwide incidence and mortality rates due to cancer continue to rise, with the burden of disease increasingly shifting to developing countries. Several optical diagnostic methods are under development to enable earlier detection of cancer, however, these are primarily intended for use in healthcare facilities in industrialized countries. Using knowledge gained from early clinical studies with large-scale prototype systems, we have designed and tested low-cost, portable versions of these instruments. We propose that these systems may be used for early diagnosis and screening in developing countries, and that pilot clinical studies are warranted in these low-resource settings.

  • Autofluorescence and diffuse reflectance spectroscopy of oral epithelial tissue using a depth-sensitive fiber-optic probe

    by Richard A. Schwarz, Wen Gao, Dania Daye, Michelle D. Williams, Rebecca Richards-Kortum, Ann M. Gillenwater

    Optical spectroscopy can provide useful diagnostic information about the morphological and biochemical changes related to the progression of precancer in epithelial tissue. As precancerous lesions develop, the optical properties of both the superficial epithelium and underlying stroma are altered; measuring spectral data as a function of depth has the potential to improve diagnostic performance. We describe a clinical spectroscopy system with a depth-sensitive, ball lens coupled fiber-optic probe for noninvasive in vivo measurement of oral autofluorescence and diffuse reflectance spectra. We report results of spectroscopic measurements from oral sites in normal volunteers and in patients with neoplastic lesions of the oral mucosa; results indicate that the addition of depth selectivity can enhance the detection of optical changes associated with precancer.