BRBryan W. Reutter

Bryan W. Reutter

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bryan W. Reutter has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Arkadiusz Sitek

    Radiology Department, Massachusetts General Hospital, Boston, MA, USA; Harvard Medical School, Boston, MA, USA

    2 shared publications
  • Grant T. Gullberg

    Department of Radiotracer Development & Imaging Technology, Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, CA 94720, USA

    2 shared publications
  • Ronald H Huesman

    2 shared publications
  • Ronald H. Huesman

    Department of Radiotracer Development & Imaging Technology, Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, CA 94720, USA

    2 shared publications
  • Rostyslav Boutchko

    Department of Radiotracer Development & Imaging Technology, Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, CA 94720, USA

    2 shared publications
  • Elias H. Botvinick

    Departments of Radiology & Medicine, University of California, San Francisco, CA 94143 USA

    1 shared publication

Latest Publications

  • Open Access

    Longitudinal Evaluation of Fatty Acid Metabolism in Normal and Spontaneously Hypertensive Rat Hearts with Dynamic MicroSPECT Imaging

    by Bryan W. Reutter, Ronald H. Huesman, Kathleen M. Brennan, Rostyslav Boutchko, Stephen M. Hanrahan, Grant T. Gullberg

    The goal of this project is to develop radionuclide molecular imaging technologies using a clinical pinhole SPECT/CT scanner to quantify changes in cardiac metabolism using the spontaneously hypertensive rat (SHR) as a model of hypertensive-related pathophysiology. This paper quantitatively compares fatty acid metabolism in hearts of SHR and Wistar-Kyoto normal rats as a function of age and thereby tracks physiological changes associated with the onset and progression of heart failure in the SHR model. The fatty acid analog, 123I-labeled BMIPP, was used in longitudinal metabolic pinhole SPECT imaging studies performed every seven months for 21 months. The uniqueness of this project is the development of techniques for estimating the blood input function from projection data acquired by a slowly rotating camera that is imaging fast circulation and the quantification of the kinetics of 123I-BMIPP by fitting compartmental models to the blood and tissue time-activity curves.


    • 1 July 2006
      • Vol. 47  (7) , 1187-92

    Method of generating multiple sets of experimental phantom data.

    by Arkadiusz Sitek, Bryan W Reutter, Ronald H Huesman, Grant T Gullberg

    Currently, 2 types of phantoms (physical and computer generated) are used for testing and comparing tomographic reconstruction methods. Data from physical phantoms include all physical effects associated with the detection of radiation. However, with physical phantoms it is difficult to control the number of detected counts, simulate the dynamics of uptake and washout, or create multiple noise realizations of an acquisition. Computer-generated phantoms can overcome some of the disadvantages of physical phantoms, but simulation of all factors affecting the detection of radiation is extremely complex and in some cases impossible. To overcome the problems with both types of phantoms, we developed a physical and computer-generated hybrid phantom that allows the creation of multiple noise realizations of tomographic datasets of the dynamic uptake governed by kinetic models. The method is phantom and camera specific. We applied it to an anthropomorphic torso phantom with a cardiac insert, using a SPECT system with attenuation correction. First, real data were acquired. For each compartment (heart, blood pool, liver, and background) of the physical phantom, large numbers of short tomographic projections were acquired separately for each angle. Sinograms were built from a database of projections by summing the projections of each compartment of the phantom. The amount of activity in each phantom compartment was regulated by the number of added projections. Sinograms corresponding to various projection times, configurations and numbers of detector heads, numbers of noise realizations, numbers of phantom compartments, and compartment-specific time-activity curves in MBq/cm3 were assembled from the database. The acquisition produced a database of 120 projection angles ranging over 360 degrees . For each angle, 300 projections of 0.5 s each were stored in 128 x 128 matrices for easy access. The acquired database was successful in the generation of static and dynamic sinograms for which the myocardial uptake and washout was governed by a compartment kinetic model. A method has been developed that allows creation of sinograms of physical phantoms with the capacity to control the number of noise realizations, the level of noise, the dynamics of uptake in the phantom compartments, and the acquisition parameters and acquisition modes.


  • Modeling Spatial Smoothness in Fully 3-D SPECT Image Reconstruction Using Multiresolution B-Splines

    by Bryan W. Reutter, Grant T. Gullberg, Arkadiusz Sitek, Rostyslav Boutchko, Elias H. Botvinick, Ronald H. Huesman

    We investigated the use of B-spline spatial basis functions to model continuous 3-D tracer distributions in cardiac SPECT studies. This approach is motivated by goals of achieving a well-posed image reconstruction problem and computational efficiency. Uniform B-spline basis functions have the noteworthy property that splines having larger spatial support can be composed from a linear combination of splines having smaller support, thus facilitating creation of a multiresolution spatial model. B-splines can be evaluated quickly when calculating projection data models or displaying reconstructed images, and there is no image "blockiness" because B-splines yield a spatially continuous representation. We used trilinear B-splines to reconstruct images for a 99mTc-sestamibi cardiac SPECT/CT patient study. Attenuation and depth-dependent point response were modeled. Spline coefficients were estimated by minimizing a least-squares criterion by direct matrix inversion. Images were reconstructed with use of (1) more-spatially-compact splines, (2) less-spatially-compact splines, and (3) a multiresolution basis composed of more-compact splines in the heart volume and less-compact splines elsewhere. Image noise was reduced with use of less-compact or multiresolution splines, and the multiresolution basis also yielded good myocardial resolution. Encouraged by these results, we are using multiresolution B-splines to analyze dynamic SPECT data from rest/stress cardiac patient studies.


    • 1 November 2004
      • Vol. 45  (11) , 1950-9

    Kinetic analysis of 18F-fluorodihydrorotenone as a deposited myocardial flow tracer: comparison to 201Tl.

    by Robert C Marshall, Patricia Powers-Risius, Bryan W Reutter, James P O'neil, Michael La Belle, Ronald H Huesman, Henry F VanBrocklin

    The goals of this investigation were to assess the accuracy of (18)F-fluorodihydrorotenone ((18)F-FDHR) as a new deposited myocardial flow tracer and to compare the results to those for (201)Tl. The kinetics of these flow tracers in 22 isolated, erythrocyte- and albumin-perfused rabbit hearts were evaluated over a flow range encountered in patients. The 2 flow tracers plus a vascular reference tracer ((131)I-albumin) were introduced as a bolus through a port just above the aortic cannula. Myocardial extraction, retention, washout, and uptake parameters were computed from the venous outflow curves with the multiple-indicator dilution technique and spectral analysis. The mean +/- SD initial extraction fractions for (18)F-FDHR (0.85 +/- 0.07) and (201)Tl (0.87 +/- 0.05) were not significantly different, although the initial extraction fraction for (18)F-FDHR declined with flow (P < 0.0001), whereas the initial extraction fraction for (201)Tl did not. The washout of (201)Tl was faster (P < 0.001) and more affected by flow (P < 0.05) than was the washout of (18)F-FDHR. Except for the initial extraction fraction, (18)F-FDHR retention was higher (P < 0.001) and less affected by flow (P < 0.05) than was (201)Tl retention. Reflecting its superior retention, the net uptake of (18)F-FDHR was better correlated with flow than was that of (201)Tl at both 1 and 15 min after tracer introduction (P < 0.0001 for both comparisons). The superior correlation of (18)F-FDHR uptake with flow indicates that it is a better flow tracer than (201)Tl in the isolated rabbit heart. Compared with the other currently available positron-emitting flow tracers ((82)Rb, (13)N-ammonia, and (15)O-water), (18)F-FDHR has the potential of providing excellent image resolution without the need for an on-site cyclotron.


  • Effects of temporal modelling on the statistical uncertainty of spatiotemporal distributions estimated directly from dynamic SPECT projections

    by B W Reutter, G T Gullberg, R H Huesman

    Artefacts can result when reconstructing a dynamic image sequence from inconsistent single photon emission computed tomography (SPECT) projection data acquired by a slowly rotating gantry. The artefacts can lead to biases in kinetic parameters estimated from time-activity curves generated by overlaying volumes of interest on the images. Insufficient sampling and truncation of projections by cone-beam collimators can cause additional artefacts. To overcome these sources of bias in conventional image based dynamic data analysis, we have been investigating the estimation of time-activity curves and kinetic model parameters directly from dynamic SPECT projection data by modelling the spatial and temporal distribution of the radiopharmaceutical throughout the projected field of view. In the present work, we perform Monte Carlo simulations to study the effects of the temporal modelling on the statistical variability of the reconstructed spatiotemporal distributions. The simulations utilize fast methods for fully four-dimensional (4D) direct estimation of spatiotemporal distributions and their statistical uncertainties, using a spatial segmentation and temporal B-splines. The simulation results suggest that there is benefit in modelling higher orders of temporal spline continuity. In addition, the accuracy of the time modelling can be increased substantially without unduly increasing the statistical uncertainty, by using relatively fine initial time sampling to capture rapidly changing activity distributions.


  • Direct least-squares estimation of spatiotemporal distributions from dynamic SPECT projections using a spatial segmentation and temporal B-splines

    by B.W. Reutter, G.T. Gullberg, R.H. Huesman

    Artifacts can result when reconstructing a dynamic image sequence from inconsistent, as well as insufficient and truncated, cone beam single photon emission computed tomography (SPECT) projection data acquired by a slowly rotating gantry. The artifacts can lead to biases in kinetic model parameters estimated from time-activity curves generated by overlaying volumes of interest on the images. However, the biases in time-activity curve estimates and subsequent kinetic parameter estimates can be reduced significantly by first modeling the spatial and temporal distribution of the radiopharmaceutical throughout the projected field of view, and then estimating the time-activity curves directly from the projections. This approach is potentially useful for clinical SPECT studies involving slowly rotating gantries, particularly those using a single-detector system or body contouring orbits with a multidetector system. We have implemented computationally efficient methods for fully four-dimensional (4-D) direct estimation of spatiotemporal distributions from dynamic SPECT projection data. Temporal B-splines providing various orders of temporal continuity, as well as various time samplings, were used to model the time-activity curves for segmented blood pool and tissue volumes in simulated cone beam and parallel beam cardiac data acquisitions. Least-squares estimates of time-activity curves were obtained quickly using a workstation. Given faithful spatial modeling, accurate curve estimates were obtained using cubic, quadratic, or linear B-splines and a relatively rapid time sampling during initial tracer uptake. From these curves, kinetic parameters were estimated accurately for noiseless data and with some bias for noisy data. A preliminary study of spatial segmentation errors showed that spatial model mismatch adversely affected quantitative accuracy, but also resulted in structured errors (projected model versus raw data) that were easily detected in our simulations. This suggests iterative refinement of the spatial model to reduce structured errors as an area of future research.