TNTakahiro Nakagawa

Takahiro Nakagawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Takahiro Nakagawa has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Chie Takada

    Nuclear Fuel Cycle Engineering Laboratories , Japan Atomic Energy Agency , 4-33, Muramatsu, Tokai-mura, Naka-gun, Ibaraki-ken 319-1197 , Japan

    1 shared publication
  • Kenji Kobayashi

    Nuclear Fuel Cycle Engineering Laboratories, Japan Atomic Energy Agency Radiation Protection Department 4-33 Muramatsu, Tokai-mura, Ibaraki 319-1194

    1 shared publication
  • Misaki Hirato

    Nuclear Fuel Cycle Engineering Laboratories, Japan Atomic Energy Agency Radiation Protection Department 4-33 Muramatsu, Tokai-mura, Ibaraki 319-1194

    1 shared publication
  • Norio Tsujimura

    Japan Atomic Energy Agency

    1 shared publication
  • Satoshi Shioya

    Nuclear Fuel Cycle Engineering Laboratories, Japan Atomic Energy Agency Radiation Protection Department 4-33 Muramatsu, Tokai-mura, Ibaraki 319-1194

    1 shared publication
  • Tatsuya Ishii

    Nuclear Fuel Cycle Engineering Laboratories, Japan Atomic Energy Agency Radiation Protection Department 4-33 Muramatsu, Tokai-mura, Ibaraki 319-1194

    1 shared publication

Latest Publications

  • Development of α-ray visualization survey meter in high gamma and neutron background environment

    by Youichi Tsubota, Kenji Kobayashi, Tatsuya Ishii, Misaki Hirato, Satoshi Shioya, Takahiro Nakagawa

    A survey meter was developed to reliably detect and visualize surface contamination of suits and objects by α-nuclides in high γ/n-rays background radiation environment. The survey meter features a semi-opaque ZnS:Ag scintillator mounted directly onto a multi-anode photomultiplier tube (MA-PMT) and amplification circuits, ensuring output gain equalization for all channels. α-ray events induce localized light emission in thin-film scintillators. By directly mounting the scintillator, diffusion of light before reaching the MA-PMT is suppressed, concentrating it in just a few channels, thereby facilitating discrimination from background radiation. This design also enables clear visualization of the shape of surface contamination. The prototyped survey meter is capable of responding up to 2.1 × 107 cpm, with no γ-ray response even in high-radiation environments exceeding 1 Sv/h. In actual environments with high background radiation, contamination of ~1/100th of the surface contamination density limit of 4 Bq/cm2 could be reliably detected.


  • Verification analysis of thermoluminescent albedo neutron dosimetry at MOX fuel facilities

    by Takahiro Nakagawa, Chie Takada, Norio Tsujimura

    Radiation workers engaging in the fabrication of MOX fuels at the Japan Atomic Energy Agency-Nuclear Fuel Cycle Engineering Laboratories are exposed to neutrons. Accordingly, thermoluminescent albedo dosemeters (TLADs) are used for individual neutron dosimetry. Because dose estimation using TLADs is susceptible to variation of the neutron energy spectrum, the authors have provided TLADs incorporating solid-state nuclear tracks detectors (SSNTDs) to selected workers who are routinely exposed to neutrons and have continued analysis of the relationship between the SSNTD and the TLAD (T/Rf) over the past 6 y from 2004 to 2009. Consequently, the T/Rf value in each year was less than the data during 1991–1993, although the neutron spectra had not changed since then. This decrease of the T/Rf implies that the ratio of operation time nearby gloveboxes and the total work time has decreased.