Shouzhuo Yao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shouzhuo Yao has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Qian Liu
Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences
14 shared publications Fei Tang
State Key Lab of Chemo/Biosensing & Chemometrics, College of Chemistry & Chemical Engineering, Hunan University, Changsha, China
8 shared publicationsFei Yang
State Key Lab of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, P. R. China
4 shared publicationsLihua Yao
State Key Lab of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, PR China
4 shared publicationsYan Huang
State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, China
4 shared publicationsYanqing Li
State Key Lab of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, P. R. China
4 shared publications
Latest Publications
- 21 July 2011
- Published by Wiley in Journal of Separation Science
- Vol. 34 (18) , 2441-2447
Nonionic surfactant enhanced semipermanent coatings for capillary electrophoresis of inorganic anions without use of organic additives
Separation of inorganic anions by capillary electrophoresis (CE) is usually conducted in co‐electroosmotic mode due to the large electrophoretic mobilities of inorganic anions. Semipermanent surfactant coatings have been shown to be effective for CE of inorganic anions due to their strong capability of electroosmotic flow (EOF) manipulation. However, semipermanent coatings often suffer from their unsatisfactory stability. In addition, organic solvent additives are usually required to adjust the selectivity, which also aggravate the degradation of coating. In this work, a novel semipermanent coating consisting of cationic Gemini surfactant 18‐10‐18 and nonionic surfactant Tween 20 was developed to separate inorganic anions in CE. This coating is easy to prepare and more stable than pure Gemini coating. The introduction of nonionic surfactant in the coating not only suppresses the reversed EOF but can also adjust the selectivity of separation. Good separations of six model anions were achieved, the separation efficiency was as high as 65040–169700 plates/m and the RSDs of the migration times were less than 0.5 and 2.5% for run‐to‐run and day‐to‐day assays, respectively. Calibration curves were linear in the range of 0.05−5.0 mM; the detection limits ranged from 20 to 50 μM. More importantly, no organic solvents are required in the background buffer to achieve the satisfactory separations. This guarantees the coating stability and makes the method greener than most of other methods for CE of inorganic anions.
- 21 July 2011
- Published by Wiley in Journal of Separation Science
- Vol. 34 (18) , 2441-2447
Nonionic surfactant enhanced semipermanent coatings for capillary electrophoresis of inorganic anions without use of organic additives
Separation of inorganic anions by capillary electrophoresis (CE) is usually conducted in co‐electroosmotic mode due to the large electrophoretic mobilities of inorganic anions. Semipermanent surfactant coatings have been shown to be effective for CE of inorganic anions due to their strong capability of electroosmotic flow (EOF) manipulation. However, semipermanent coatings often suffer from their unsatisfactory stability. In addition, organic solvent additives are usually required to adjust the selectivity, which also aggravate the degradation of coating. In this work, a novel semipermanent coating consisting of cationic Gemini surfactant 18‐10‐18 and nonionic surfactant Tween 20 was developed to separate inorganic anions in CE. This coating is easy to prepare and more stable than pure Gemini coating. The introduction of nonionic surfactant in the coating not only suppresses the reversed EOF but can also adjust the selectivity of separation. Good separations of six model anions were achieved, the separation efficiency was as high as 65040–169700 plates/m and the RSDs of the migration times were less than 0.5 and 2.5% for run‐to‐run and day‐to‐day assays, respectively. Calibration curves were linear in the range of 0.05−5.0 mM; the detection limits ranged from 20 to 50 μM. More importantly, no organic solvents are required in the background buffer to achieve the satisfactory separations. This guarantees the coating stability and makes the method greener than most of other methods for CE of inorganic anions.
- 15 February 2011
- Published by Wiley in Journal of Separation Science
- Vol. 34 (6) , 716-723
Ultrasonication extraction coupled with magnetic solid‐phase clean‐up for the determination of polycyclic aromatic hydrocarbons in soils by high‐performance liquid chromatography
C18‐functionalized magnetic microspheres synthesized in a three‐stage system and characterized by Fourier transform infrared (FTIR) spectroscopy and SEM were applied for clean‐up and enrichment of polycyclic aromatic hydrocarbons (PAHs) in soil samples combined with ultrasonication extraction. Magnetic solid‐phase extraction (MSPE) parameters, such as elution solvents, amounts of sorbents, enrichment time and organic modifier, were optimized together with ultrasonication time and extraction solvents. Under the optimal conditions, the developed method provided spiked recoveries of 63.2–92.8% with RSDs of less than 6.4% and limits of detection were 0.5–1.0 ng/g. This new method provides several advantages, such as high extraction efficiency, convenient extraction procedure and short analysis times. Finally, the method was successfully applied to the determination of polycyclic aromatic hydrocarbons in soil samples.
- 15 February 2011
- Published by Wiley in Journal of Separation Science
- Vol. 34 (6) , 716-723
Ultrasonication extraction coupled with magnetic solid‐phase clean‐up for the determination of polycyclic aromatic hydrocarbons in soils by high‐performance liquid chromatography
C18‐functionalized magnetic microspheres synthesized in a three‐stage system and characterized by Fourier transform infrared (FTIR) spectroscopy and SEM were applied for clean‐up and enrichment of polycyclic aromatic hydrocarbons (PAHs) in soil samples combined with ultrasonication extraction. Magnetic solid‐phase extraction (MSPE) parameters, such as elution solvents, amounts of sorbents, enrichment time and organic modifier, were optimized together with ultrasonication time and extraction solvents. Under the optimal conditions, the developed method provided spiked recoveries of 63.2–92.8% with RSDs of less than 6.4% and limits of detection were 0.5–1.0 ng/g. This new method provides several advantages, such as high extraction efficiency, convenient extraction procedure and short analysis times. Finally, the method was successfully applied to the determination of polycyclic aromatic hydrocarbons in soil samples.
- 15 December 2010
- Published by Royal Society of Chemistry (RSC) in Journal of Environmental Monitoring
- Vol. 13 (2) , 440-445
Magnetic microsphere confined ionic liquid as a novel sorbent for the determination of chlorophenols in environmental water samples by liquid chromatography
Magnetic microsphere confined ionic liquid was synthesized by covalently bonding N-methylimidazolium on magnetic microspheres. The functionalized magnetic microspheres were characterized by Fourier transform infrared (FT-IR) spectrometry, thermogravimetric analysis (TGA) and scanning electron microscopy (SEM). The prepared material was used for the preconcentration of three chlorophenols (CPs) in water combined with high-performance liquid chromatography (HPLC). Several conditions that probably affected the extraction efficiency such as standing time, eluent and its volume, sample pH and volume, were optimized. Under the optimal conditions, good recoveries (70.3–88.8%) were achieved with satisfactory relative standard deviations (RSDs) of less than 6.0%. The limits of detection for the three CPs were 0.20–0.35 μg L−1. The results indicated that the ionic liquid-functionalized magnetic microspheres show significant promise for the analysis of CPs in environmental samples.
- 15 December 2010
- Published by Royal Society of Chemistry (RSC) in Journal of Environmental Monitoring
- Vol. 13 (2) , 440-445
Magnetic microsphere confined ionic liquid as a novel sorbent for the determination of chlorophenols in environmental water samples by liquid chromatography
Magnetic microsphere confined ionic liquid was synthesized by covalently bonding N-methylimidazolium on magnetic microspheres. The functionalized magnetic microspheres were characterized by Fourier transform infrared (FT-IR) spectrometry, thermogravimetric analysis (TGA) and scanning electron microscopy (SEM). The prepared material was used for the preconcentration of three chlorophenols (CPs) in water combined with high-performance liquid chromatography (HPLC). Several conditions that probably affected the extraction efficiency such as standing time, eluent and its volume, sample pH and volume, were optimized. Under the optimal conditions, good recoveries (70.3–88.8%) were achieved with satisfactory relative standard deviations (RSDs) of less than 6.0%. The limits of detection for the three CPs were 0.20–0.35 μg L−1. The results indicated that the ionic liquid-functionalized magnetic microspheres show significant promise for the analysis of CPs in environmental samples.
- 1 September 2010
- Published by Springer Nature in Science China Chemistry
- Vol. 53 (11) , 2349-2356
Electrochemical quartz crystal microbalance study on Au-supported Pt adlayers for electrocatalytic oxidation of methanol in alkaline solution
- 1 September 2010
- Published by Springer Nature in Science China Chemistry
- Vol. 53 (11) , 2349-2356
Electrochemical quartz crystal microbalance study on Au-supported Pt adlayers for electrocatalytic oxidation of methanol in alkaline solution
- 29 July 2010
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 135 (9) , 2426-2433
Ionic liquid-coated Fe3O4 magnetic nanoparticles as an adsorbent of mixed hemimicelles solid-phase extraction for preconcentration of polycyclic aromatic hydrocarbons in environmental samples
In this paper, ionic liquid (IL)-coated magnetic Fe3O4 nanoparticles (NPs) as an adsorbent of mixed hemimicelles solid-phase extraction (SPE) was investigated for the preconcentration of polycyclic aromatic hydrocarbons (PAHs) from environmental samples. Due to the high surface area and excellent adsorption capacity of the Fe3O4 NPs after modification with ILs, satisfactory extraction recoveries can be achieved with only 80 mg Fe3O4 NPs, 50 mg IL, 300 mL solution at pH = 10 and 10 min for equilibration. A comprehensive study of the adsorption conditions such as the amount of Fe3O4 NPs and ILs, the solution pH, ionic strength, standing time, breakthrough volume, and desorption solvents was presented. The extraction ability of different coating agents, such as 1-hexadecyl-3-methylimidazolium bromide (C16mimBr), 1-decyl-3-methylimidazolium bromide (C10mimBr) and cationic surfactant cetyltrimethylammonium bromide (CTAB) was also compared. Under the optimized conditions, the recoveries for the water samples analysis were between 76 and 105% with relative standard deviations (RSDs) ranging from 3.9 to 6.9%, and the recoveries for soil samples were between 73 and 104% with RSDs ranging from 1.0 to 6.3%. In this method, only a small amount of C16mimBr (50 mg) and Fe3O4 NPs (80 mg) was needed to obtain satisfactory recoveries.
- 29 July 2010
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 135 (9) , 2426-2433
Ionic liquid-coated Fe3O4 magnetic nanoparticles as an adsorbent of mixed hemimicelles solid-phase extraction for preconcentration of polycyclic aromatic hydrocarbons in environmental samples
In this paper, ionic liquid (IL)-coated magnetic Fe3O4 nanoparticles (NPs) as an adsorbent of mixed hemimicelles solid-phase extraction (SPE) was investigated for the preconcentration of polycyclic aromatic hydrocarbons (PAHs) from environmental samples. Due to the high surface area and excellent adsorption capacity of the Fe3O4 NPs after modification with ILs, satisfactory extraction recoveries can be achieved with only 80 mg Fe3O4 NPs, 50 mg IL, 300 mL solution at pH = 10 and 10 min for equilibration. A comprehensive study of the adsorption conditions such as the amount of Fe3O4 NPs and ILs, the solution pH, ionic strength, standing time, breakthrough volume, and desorption solvents was presented. The extraction ability of different coating agents, such as 1-hexadecyl-3-methylimidazolium bromide (C16mimBr), 1-decyl-3-methylimidazolium bromide (C10mimBr) and cationic surfactant cetyltrimethylammonium bromide (CTAB) was also compared. Under the optimized conditions, the recoveries for the water samples analysis were between 76 and 105% with relative standard deviations (RSDs) ranging from 3.9 to 6.9%, and the recoveries for soil samples were between 73 and 104% with RSDs ranging from 1.0 to 6.3%. In this method, only a small amount of C16mimBr (50 mg) and Fe3O4 NPs (80 mg) was needed to obtain satisfactory recoveries.