Thomas Walski
Research Subjects
Thomas Walski has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Zheng Yi Wu
Bentley Systems Inc., 76 Watertown Rd, Suite 2D, Thomaston, CT 06787, USA
8 shared publications - Enrico Creaco
Dipartimento di Ingegneria Civile e Architettura University of Pavia Pavia Italy
6 shared publications Brian Whitman
Department of Environmental Engineering and Earth Sciences, Wilkes University Wilkes‐Barre Pennsylvania
4 shared publicationsBrian E. Whitman
Senior Product Manager, Bentley Systems, 3 Brian's Place, Nanticoke, PA 18634
2 shared publicationsBryce Edwards
Senior Product Manager, Bentley Systems, 3 Brian's Place, Nanticoke, PA 18634
2 shared publications- Christopher C. Baggett
Jones Edmunds & Associates, Inc., 730 NE Waldo Road, Gainesville, FL 32641
2 shared publications
Latest Publications
- 28 December 2024
- Published by Springer Nature
- p. 147-165
Strategic Decision-Making in Water Utilities: Historical Insights and Emerging Analytics for Water Mains Repair Versus Replacement Decision
- 28 December 2024
- Published by Springer Nature
- p. 147-165
Strategic Decision-Making in Water Utilities: Historical Insights and Emerging Analytics for Water Mains Repair Versus Replacement Decision
- Open Access
- 14 May 2020
- Published by American Society of Civil Engineers (ASCE)
- p. 329-339
Identifying Vulnerable and Critical Water Distribution Segments
The purpose of this study is to develop a graph theoretic approach to evaluate segment vulnerability and importance (or criticality), so that isolation valves may be more strategically placed and key isolation valves can be identified. The method quantifies reachability from sources to segments for given segment isolation scenarios, allowing identification of critical and vulnerable segments. An important feature of this work is that it distinguishes between true sources (wells, treatment plants) and ephemeral sources (storage tanks) which have limited capacity. The capability to visually identify key segments is another advance presented in this paper. Preliminary results further indicate that the method captures the decrease in segment vulnerability as the number of valves increases in a network.
- 14 May 2020
- Published by American Society of Civil Engineers (ASCE)
- p. 329-339
Open AccessIdentifying Vulnerable and Critical Water Distribution Segments
The purpose of this study is to develop a graph theoretic approach to evaluate segment vulnerability and importance (or criticality), so that isolation valves may be more strategically placed and key isolation valves can be identified. The method quantifies reachability from sources to segments for given segment isolation scenarios, allowing identification of critical and vulnerable segments. An important feature of this work is that it distinguishes between true sources (wells, treatment plants) and ephemeral sources (storage tanks) which have limited capacity. The capability to visually identify key segments is another advance presented in this paper. Preliminary results further indicate that the method captures the decrease in segment vulnerability as the number of valves increases in a network.
- Open Access
- 12 November 2019
- Published by MDPI AG in Proceedings
- Vol. 48 (1) , 20
Flowing Blow-Offs: A Solution to Maintain Adequate Disinfectant Residuals of Dead-End Nodes in WDNs
Flushing plans within a water distribution network (WDN) provide a tool for improving disinfectant residuals and removing stagnant water. The problem of low disinfectant residuals occurs in areas of a WDN such as dead-end nodes, in which low flow conditions and long residence times lead to excessive decay of the disinfectant upstream from users. Here, a methodology is presented to maintain adequate disinfectant residuals in WDNs that have numerous dead-end nodes. The slight increase in nodal outflows at these sites, which can be obtained through the opening of a blow-off at the hydrant site, can help in tackling this problem. The methodology is based on the combined use of optimization and of flow routing/water quality modelling. The concentration of disinfectant at the source(s) and the values of nodal emitter coefficients at the critical dead-end nodes are the decisional variables to be optimized. Two objective functions are considered in the optimization, namely the total volume of water delivered in the network and the total mass of disinfectant injected into the network. The effectiveness of the methodology is proven on a real WDN, yielding an insight into the economic feasibility of the solution.
- 12 November 2019
- Published by MDPI AG in Proceedings
- Vol. 48 (1) , 20
Open AccessFlowing Blow-Offs: A Solution to Maintain Adequate Disinfectant Residuals of Dead-End Nodes in WDNs
Flushing plans within a water distribution network (WDN) provide a tool for improving disinfectant residuals and removing stagnant water. The problem of low disinfectant residuals occurs in areas of a WDN such as dead-end nodes, in which low flow conditions and long residence times lead to excessive decay of the disinfectant upstream from users. Here, a methodology is presented to maintain adequate disinfectant residuals in WDNs that have numerous dead-end nodes. The slight increase in nodal outflows at these sites, which can be obtained through the opening of a blow-off at the hydrant site, can help in tackling this problem. The methodology is based on the combined use of optimization and of flow routing/water quality modelling. The concentration of disinfectant at the source(s) and the values of nodal emitter coefficients at the critical dead-end nodes are the decisional variables to be optimized. Two objective functions are considered in the optimization, namely the total volume of water delivered in the network and the total mass of disinfectant injected into the network. The effectiveness of the methodology is proven on a real WDN, yielding an insight into the economic feasibility of the solution.
- Top Cited Papers
- 1 September 2019
- Published by Elsevier in Water Research
- Vol. 161, 517-530
Real time control of water distribution networks: A state-of-the-art review
- 1 September 2019
- Published by Elsevier in Water Research
- Vol. 161, 517-530
Top Cited PapersReal time control of water distribution networks: A state-of-the-art review
- Open Access
- 2 May 2019
- Published by Wiley in Journal AWWA
- Vol. 111 (5) , 31-34
Why Global Standards for Calibration of Water Distribution Models Won't Work
You would think it would be easy to develop numerical standards for model calibration. It isn't.
- 2 May 2019
- Published by Wiley in Journal AWWA
- Vol. 111 (5) , 31-34
Open AccessWhy Global Standards for Calibration of Water Distribution Models Won't Work
You would think it would be easy to develop numerical standards for model calibration. It isn't.
- 1 March 2019
- Published by Wiley in AWWA Water Science
- Vol. 1 (2)
Pressure‐dependent demand under pressure‐deficient conditions
This article shows that for pressure‐dependent demand (PDD) modeling, as pressures become very low, not only does the decrease in pressure affect outflow from orifices (faucets, showers, leaks), but it can leave some orifices above the hydraulic grade. The orifices above the hydraulic grade line would not have flowed at all. This has implications for the PDD function used in some hydraulic models in that a simple orifice equation cannot accurately describe such nodal demands. This article presents the results of lab experiments that measure the effect of very low pressures on demands. An equation that accounts for the influence of very low pressure and orifice elevation is proposed and verified. The impact of this equation on modeling low‐pressure situations is presented.
- 1 March 2019
- Published by Wiley in AWWA Water Science
- Vol. 1 (2)
Pressure‐dependent demand under pressure‐deficient conditions
This article shows that for pressure‐dependent demand (PDD) modeling, as pressures become very low, not only does the decrease in pressure affect outflow from orifices (faucets, showers, leaks), but it can leave some orifices above the hydraulic grade. The orifices above the hydraulic grade line would not have flowed at all. This has implications for the PDD function used in some hydraulic models in that a simple orifice equation cannot accurately describe such nodal demands. This article presents the results of lab experiments that measure the effect of very low pressures on demands. An equation that accounts for the influence of very low pressure and orifice elevation is proposed and verified. The impact of this equation on modeling low‐pressure situations is presented.
- 1 November 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 144 (11)
Operation and Cost-Effectiveness of Local and Remote RTC
This paper analyses the cost-effectiveness of two different variants of real-time pressure control (RTC) of valves in water distribution networks (WDNs), namely, the local and remote RTC. The system considered for RTC application is made up of a WDN pressure zone fed through a single-control valve. Whereas both variants of RTC are based on dynamically adjusting the valve settings, the main difference lies in the source of the measurements used, that is, local measurements taken at the valve site and remote measurements from the critical node, respectively. The analysis was carried out considering RTC installation costs and operational costs associated with water production and expected pipe burst repairs, while taking as benchmark the no-control scenario. The two kinds of operational cost were evaluated through pressure-driven extended-period simulation with stochastic nodal demands and empirical modeling, respectively. The results pointed out that the local RTC is more cost-effective for small pressure zones. Resorting to remote RTC is justified only for larger systems.
- 1 November 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 144 (11)
Operation and Cost-Effectiveness of Local and Remote RTC
This paper analyses the cost-effectiveness of two different variants of real-time pressure control (RTC) of valves in water distribution networks (WDNs), namely, the local and remote RTC. The system considered for RTC application is made up of a WDN pressure zone fed through a single-control valve. Whereas both variants of RTC are based on dynamically adjusting the valve settings, the main difference lies in the source of the measurements used, that is, local measurements taken at the valve site and remote measurements from the critical node, respectively. The analysis was carried out considering RTC installation costs and operational costs associated with water production and expected pipe burst repairs, while taking as benchmark the no-control scenario. The two kinds of operational cost were evaluated through pressure-driven extended-period simulation with stochastic nodal demands and empirical modeling, respectively. The results pointed out that the local RTC is more cost-effective for small pressure zones. Resorting to remote RTC is justified only for larger systems.
- 1 December 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 143 (12)
Economic Analysis of Pressure Control for Leakage and Pipe Burst Reduction
This paper presents an economic analysis of pressure control solutions for leakage and pipe burst reduction. In detail, it explores the operating conditions under which the installation of conventional mechanical pressure reducing valves (PRVs) or remotely real-time controlled (RTC) valves are cost effective compared to a scenario with no control. For a range of system sizes, hydraulic extended period simulations and empirical formulas were used to estimate leakage rates and pipe bursts, respectively, in numerous operational scenarios, including different precontrol leakage levels and demand patterns, the absence of pressure control, and the installation of a PRV or RTC valve. The total cost of the controlled system, including the installation cost of the control device, the flow-dependent operation and maintenance (O&M) cost, and the pipe burst repair cost over the planning horizon, was compared with the water-related O&M and pipe burst repair costs of the uncontrolled system. The results pointed out that no pressure controls are needed if leakage and the variable O&M cost of water are low. When these variables are high, remote RTC is attractive, especially when the demand pattern is peaked and the system is large. For more moderate cost and leakage, a conventional PRV may be better than RTC, especially in small systems and for relatively smooth demand patterns.
- 1 December 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 143 (12)
Economic Analysis of Pressure Control for Leakage and Pipe Burst Reduction
This paper presents an economic analysis of pressure control solutions for leakage and pipe burst reduction. In detail, it explores the operating conditions under which the installation of conventional mechanical pressure reducing valves (PRVs) or remotely real-time controlled (RTC) valves are cost effective compared to a scenario with no control. For a range of system sizes, hydraulic extended period simulations and empirical formulas were used to estimate leakage rates and pipe bursts, respectively, in numerous operational scenarios, including different precontrol leakage levels and demand patterns, the absence of pressure control, and the installation of a PRV or RTC valve. The total cost of the controlled system, including the installation cost of the control device, the flow-dependent operation and maintenance (O&M) cost, and the pipe burst repair cost over the planning horizon, was compared with the water-related O&M and pipe burst repair costs of the uncontrolled system. The results pointed out that no pressure controls are needed if leakage and the variable O&M cost of water are low. When these variables are high, remote RTC is attractive, especially when the demand pattern is peaked and the system is large. For more moderate cost and leakage, a conventional PRV may be better than RTC, especially in small systems and for relatively smooth demand patterns.
- 1 August 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 143 (8)
Discussion of “Optimization of Water Distribution Networks for Combined Hydropower Energy Recovery and Leakage Reduction” by Lucy Corcoran, Aonghus McNabola, and Paul Coughlan
- 1 August 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 143 (8)
Discussion of “Optimization of Water Distribution Networks for Combined Hydropower Energy Recovery and Leakage Reduction” by Lucy Corcoran, Aonghus McNabola, and Paul Coughlan
- 1 August 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 143 (8)
How (Not) to Write an Abstract
- 1 August 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 143 (8)
How (Not) to Write an Abstract