SKSascha Krueger

Sascha Krueger

*This is an algorithmically generated author record based on publicly available information.

Sascha Krueger has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Magnetic resonance guided renal denervation using active tracking: first in vivo experience in Swine

    by F. Bönner, S. Haberkorn, P. Behm, B. Schnackenburg, S. Krüger, S. Weiss, C. Meyer, M. Kelm, M. Neizel-Wittke

    Interventional cardiovascular magnetic resonance (iCMR) might evolve as a technique to improve procedural success rates in cardiovascular interventions by combining intraprocedural guidance and simultaneous lesion imaging. The objective of the present study was to prove feasibility and estimate safety of renal sympathetic denervation guided by real-time iCMR using active tracking. Six pigs were examined in a 1.5 T MRI-System (Achieva, Philips Healthcare, Best, Netherlands) equipped with non-invasive hemodynamic control and in-room monitors displaying an interventional software platform [Interventional MRI Suite (iSuite), Philips Research, Hamburg, Germany]. MR-guided renal denervation was performed using a MR conditional non-irrigated ablation catheter with active tracking (Imricor, Burnsville, MN, USA). Real-time imaging for device guidance was performed with a TFE sequence, vessel patency was assessed with a 3D non-contrast angiography and velocity encoded imaging. Oedema of the renal artery was visualized by a high-resolution T2 SPIR sequence. Renal sympathetic denervation was feasible in all cases with survival of all animals. Non-contrast angiography displayed renal artery patency accompanied by equal flow conditions before and after the ablation in all cases as measured by velocity encoded imaging. Oedema imaging displayed a significant increase in relative signal intensity at renal artery ablations sites pre and post intervention (p < 0.05). The histologic examination revealed no signs of perforation or bleeding, while sufficient ablation lesions could be depicted. MR-guided renal sympathetic denervation using active tracking is feasible and the initial data suggest safety of this procedure. MR-guided renal sympathetic denervation offers the inherent strength of high soft tissue contrast thereby providing target information without the use of iodinated contrast agents or radiation.


  • Prospective active marker motion correction improves statistical power in BOLD fMRI

    by Jordan Muraskin, Melvyn B. Ooi, Robin I. Goldman, Sascha Krueger, William J. Thomas, Paul Sajda, Truman R. Brown


  • Open Access

    Accelerated 3D catheter visualization from triplanar MR projection images

    by Carsten Oliver Schirra, Steffen Weiss, Sascha Krueger, Denis Caulfield, Steen F. Pedersen, Reza Razavi, Sebastian Kozerke, Tobias Schaeffter

    One major obstacle for MR-guided catheterizations is long acquisition times associated with visualizing interventional devices. Therefore, most techniques presented hitherto rely on single-plane imaging to visualize the catheter. Recently, accelerated three-dimensional (3D) imaging based on compressed sensing has been proposed to reduce acquisition times. However, frame rates with this technique remain low, and the 3D reconstruction problem yields a considerable computational load. In X-ray angiography, it is well understood that the shape of interventional devices can be derived in 3D space from a limited number of projection images. In this work, this fact is exploited to develop a method for 3D visualization of active catheters from multiplanar two-dimensional (2D) projection MR images. This is favorable to 3D MRI as the overall number of acquired profiles, and consequently the acquisition time, is reduced. To further reduce measurement times, compressed sensing is employed. Furthermore, a novel single-channel catheter design is presented that combines a solenoidal tip coil in series with a single-loop antenna, enabling simultaneous tip tracking and shape visualization. The tracked tip and catheter properties provide constraints for compressed sensing reconstruction and subsequent 2D/3D curve fitting. The feasibility of the method is demonstrated in phantoms and in an in vivo pig experiment. Magn Reson Med, 2010.


  • Open Access

    An MR guidewire based on micropultruded fiber‐reinforced material

    by Sascha Krueger, Sebastian Schmitz, Steffen Weiss, Daniel Wirtz, Marita Linssen, Heinz Schade, Nils Kraemer, Elmar Spuentrup, Gabriele Krombach, Arno Buecker

    A novel fiber‐reinforced material for the realization of MR guidewires, made using a newly‐developed production process, is presented. The MR‐safe artificial material provides a high stiffness and torque and allows the production, in a large range of sizes, of nonmetallic MR guidewires with similar mechanical properties as conventional metallic guidewires. Based on this material, a passively visualized MR guidewire has been developed, and was found to conform to existing standards on mechanical stability. Handling and steerability were evaluated in animal studies and were found to be comparable with conventional metallic guidewires. X‐ray visibility is provided by a BaSO4‐ and tungsten‐doped jacket. A hydrophilic coating improves sliding properties and hemocompatibility. Magn Reson Med 60:1190–1196, 2008.


  • Modality-integrated magnetic catheter tracking for x-ray vascular interventions

    by Sascha Krueger, Holger Timinger, Ruediger Grewer, Joern Borgert

    A novel setup for the integration of a magnetic tracking system (MTS) into a catheter laboratory environment by attaching the field generator of the MTS to the C-arm of the x-ray system was investigated. The metal interference of the x-ray system with the MTS then becomes static and can be calibrated. The registration of a tracked catheter to 2D live x-ray images with high and well-defined accuracy is thus possible for arbitrary C-arm positions. Interference with imaging by blocking the field of view is avoided. Real-time registration methods to maintain the registration of the catheter also to static 2D or 3D images (roadmaps), regardless of the C-arm rotation during catheter tracking, were investigated. Residual registration errors of the tracked catheter with respect to the static roadmaps (2D and 3D) were reduced by using the vessel geometry and shape information. The algorithms potentially allow for motion correction (e.g. due to respiration). Using the shape-based correction algorithms the average registration accuracies to static roadmaps for different C-arm angulations and catheter positions were determined to be 3.3-4.2 mm. The magnetic registration of the C-arm was furthermore allowed to compute the imaging geometry (position of the C-arm) and to produce virtual angiographic preview images before contrast injection and x-ray dose application. Thus, optimal projection geometries and collimator settings for the target region can be chosen in an 'off line' fashion. The proposed MTS-supported navigation setup on both 3D (static) and 2D (live and static) roadmaps merges the high resolution and real-time feedback of 2D x-ray images with the navigation support from 3D static images.