Jacob Pe'ER
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jacob Pe'ER has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Shahar Frenkel
Division of Ophthalmology, Hadassah Medical Center, Jerusalem 9112001, Israel
3 shared publications Israel Barzel
Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel
2 shared publicationsA Y Lin
Department of Pathology, University of Illinois at Chicago, Chicago, USA
1 shared publicationAlexander Maly
1 shared publicationCristhian Sancho
Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel
1 shared publicationD Majumdar
Department of Mathematics, Computer Science and Statistics, University of Illinois at Chicago, Chicago, USA
1 shared publication
Latest Publications
- 19 April 2007
- Published by BMJ in British Journal of Ophthalmology
- Vol. 91 (5) , 660-662
Punch biopsy of iris lesions: a novel technique for obtaining histology samples
To obtain iris biopsy samples of sufficient quality and quantity for histopathological analysis using a novel punch biopsy technique. Two patients underwent iris tumour biopsy at an ocular oncology service. A trabeculectomy punch (Kelly Descemet's membrane punch) with a 1.0 mm diameter head and a 0.75 mm deep bite was inserted through a clear cornea perforated by a SatinSlit 3.2 mm angled slit knife into a viscoelastic-filled anterior chamber. The Kelly punch was placed over the lesion and pressed down before the punch was made. After obtaining the sample, the Kelly punch was removed from the eye and then opened over a dry cellulose sponge. Tissue samples were placed in 4% formalin and processed routinely for standard staining with H&E, periodic acid Schiff and immunostains. In both patients, by using the punch biopsy technique with the Kelly punch, we were able to obtain a 0.8 x 0.6 mm piece of tissue, large enough for any histological analysis. H&E staining showed spindle cell melanoma. Tissue sections, stained positive with MART-1 (melanoma antigen recognised by T cells) and negative with cytokeratin, established the diagnosis of melanoma of the iris in each of these patients. Iris biopsy with the punch technique yields a tissue biopsy specimen, as opposed to cytology samples obtained by fine needle aspiration biopsy. This technique is quick, simple to perform and requires non-expensive and easily available equipment. The tissue obtained is of sufficient quality and quantity to enable routine and special stainings.
- 19 April 2007
- Published by BMJ in British Journal of Ophthalmology
- Vol. 91 (5) , 660-662
Punch biopsy of iris lesions: a novel technique for obtaining histology samples
To obtain iris biopsy samples of sufficient quality and quantity for histopathological analysis using a novel punch biopsy technique. Two patients underwent iris tumour biopsy at an ocular oncology service. A trabeculectomy punch (Kelly Descemet's membrane punch) with a 1.0 mm diameter head and a 0.75 mm deep bite was inserted through a clear cornea perforated by a SatinSlit 3.2 mm angled slit knife into a viscoelastic-filled anterior chamber. The Kelly punch was placed over the lesion and pressed down before the punch was made. After obtaining the sample, the Kelly punch was removed from the eye and then opened over a dry cellulose sponge. Tissue samples were placed in 4% formalin and processed routinely for standard staining with H&E, periodic acid Schiff and immunostains. In both patients, by using the punch biopsy technique with the Kelly punch, we were able to obtain a 0.8 x 0.6 mm piece of tissue, large enough for any histological analysis. H&E staining showed spindle cell melanoma. Tissue sections, stained positive with MART-1 (melanoma antigen recognised by T cells) and negative with cytokeratin, established the diagnosis of melanoma of the iris in each of these patients. Iris biopsy with the punch technique yields a tissue biopsy specimen, as opposed to cytology samples obtained by fine needle aspiration biopsy. This technique is quick, simple to perform and requires non-expensive and easily available equipment. The tissue obtained is of sufficient quality and quantity to enable routine and special stainings.
- 13 April 2007
- Published by Springer Nature in Eye
- Vol. 21 (7) , 1010-1012
Severe radiation retinopathy and optic neuropathy after brachytherapy for choroidal melanoma, treated by hyperbaric oxygen
- 13 April 2007
- Published by Springer Nature in Eye
- Vol. 21 (7) , 1010-1012
Severe radiation retinopathy and optic neuropathy after brachytherapy for choroidal melanoma, treated by hyperbaric oxygen
- Open Access
- 16 March 2007
- Published by Springer Nature in Eye
- Vol. 22 (7) , 948-952
Demonstrating circulation in vasculogenic mimicry patterns of uveal melanoma by confocal indocyanine green angiography
Purpose Vasculogenic mimicry patterns, formed by highly invasive melanoma cells, connect to endothelial cell-lined blood vessels and contain fluid in vitroand in vivo. This study was designed to determine if fluid leaks into vasculogenic mimicry patterns without circulation, or if fluid circulates in and clears from these patterns. Methods Indocyanine green (ICG) laser scanning confocal angiography (Heidelberg Retinal Angiograph (HRA); Heidelberg Engineering, Heidelberg, Germany) was performed on nine patients with posterior choroidal melanoma in an institutional setting. Blood was drawn before the ICG injection and from the contralateral arm of the ICG injection site and 1 min after the injection. Outcome measures include time to first filling of retinal vessels and vasculogenic mimicry patterns and the time at which no fluorescence could be detected by the HRA instrument. After fluorescence was no longer detected in vessels or patterns, the tubes containing the patient's blood was imaged by the Heidelberg HRA. Results Looping vasculogenic mimicry patterns were detected focally in five patients within 30 s after injection and were detectable up to 12 min post-injection. Blood drawn before ICG injection did not autofluoresce but ICG-containing blood pooled in the tube continued to fluoresce at 1-month post-injection. Conclusions Vasculogenic mimicry patterns are not part of the endothelial cell-lined vascular system and fluid enters these patterns through leakage. The rapid infusion of ICG into these patterns after injection and the disappearance of fluorescence detectable by the Heidelberg HRA suggest that fluid circulates in these patterns and does not accumulate as a stagnant pool.
- 16 March 2007
- Published by Springer Nature in Eye
- Vol. 22 (7) , 948-952
Open AccessDemonstrating circulation in vasculogenic mimicry patterns of uveal melanoma by confocal indocyanine green angiography
Purpose Vasculogenic mimicry patterns, formed by highly invasive melanoma cells, connect to endothelial cell-lined blood vessels and contain fluid in vitroand in vivo. This study was designed to determine if fluid leaks into vasculogenic mimicry patterns without circulation, or if fluid circulates in and clears from these patterns. Methods Indocyanine green (ICG) laser scanning confocal angiography (Heidelberg Retinal Angiograph (HRA); Heidelberg Engineering, Heidelberg, Germany) was performed on nine patients with posterior choroidal melanoma in an institutional setting. Blood was drawn before the ICG injection and from the contralateral arm of the ICG injection site and 1 min after the injection. Outcome measures include time to first filling of retinal vessels and vasculogenic mimicry patterns and the time at which no fluorescence could be detected by the HRA instrument. After fluorescence was no longer detected in vessels or patterns, the tubes containing the patient's blood was imaged by the Heidelberg HRA. Results Looping vasculogenic mimicry patterns were detected focally in five patients within 30 s after injection and were detectable up to 12 min post-injection. Blood drawn before ICG injection did not autofluoresce but ICG-containing blood pooled in the tube continued to fluoresce at 1-month post-injection. Conclusions Vasculogenic mimicry patterns are not part of the endothelial cell-lined vascular system and fluid enters these patterns through leakage. The rapid infusion of ICG into these patterns after injection and the disappearance of fluorescence detectable by the Heidelberg HRA suggest that fluid circulates in these patterns and does not accumulate as a stagnant pool.
- Open Access
- 1 March 2007
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 125 (3) , 423-426
Solitary Fibrous Tumor of the Conjunctiva
Case Report from JAMA Ophthalmology — Solitary Fibrous Tumor of the Conjunctiva
- 1 March 2007
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 125 (3) , 423-426
Open AccessSolitary Fibrous Tumor of the Conjunctiva
Case Report from JAMA Ophthalmology — Solitary Fibrous Tumor of the Conjunctiva
- 1 May 2006
- Published by S. Karger AG in Ophthalmologica
- Vol. 220 (3) , 194-197
Measurement of Choroidal Melanoma Basal Diameter by Wide-Angle Digital Fundus Camera: A Comparison with Ultrasound Measurement
Purpose: To compare the measurement of the basal diameter of choroidal melanoma, an important parameter for planning treatment and as a prognostic factor, by standardized ophthalmic ultrasound versus that obtained using a wide-angle fundus camera. Methods: The longest and shortest basal diameters of 104 consecutive choroidal melanomas of patients seen at the ocular oncology service of the Hadassah University Hospital were measured by B-scan ultrasound and compared with those measured by a wide-angle fundus camera (Panoret-1000). Each diameter was measured thrice by two ophthalmic photographers, and intra-observer and interobserver reproducibility were calculated as well. Results: The measurements of both the long and short diameters of the choroidal melanomas were significantly larger when measured by Panoret-1000 as compared with the B-scan ultrasound. There was no significant difference among the three measurements of each of the photographers. The interobserver reproducibility between the two photographers was high. Conclusions: Our findings can be attributed to the larger extent of the pigmentation of the melanoma compared to its recognized elevation. Since pigmentation of choroidal melanoma is easier to recognize than its elevation, we assume that measurement by a wide-angle fundus camera is more accurate in pigmented tumors, and should be adopted for measuring the basal diameter of choroidal melanomas in planning treatment and follow-up.
- 1 May 2006
- Published by S. Karger AG in Ophthalmologica
- Vol. 220 (3) , 194-197
Measurement of Choroidal Melanoma Basal Diameter by Wide-Angle Digital Fundus Camera: A Comparison with Ultrasound Measurement
Purpose: To compare the measurement of the basal diameter of choroidal melanoma, an important parameter for planning treatment and as a prognostic factor, by standardized ophthalmic ultrasound versus that obtained using a wide-angle fundus camera. Methods: The longest and shortest basal diameters of 104 consecutive choroidal melanomas of patients seen at the ocular oncology service of the Hadassah University Hospital were measured by B-scan ultrasound and compared with those measured by a wide-angle fundus camera (Panoret-1000). Each diameter was measured thrice by two ophthalmic photographers, and intra-observer and interobserver reproducibility were calculated as well. Results: The measurements of both the long and short diameters of the choroidal melanomas were significantly larger when measured by Panoret-1000 as compared with the B-scan ultrasound. There was no significant difference among the three measurements of each of the photographers. The interobserver reproducibility between the two photographers was high. Conclusions: Our findings can be attributed to the larger extent of the pigmentation of the melanoma compared to its recognized elevation. Since pigmentation of choroidal melanoma is easier to recognize than its elevation, we assume that measurement by a wide-angle fundus camera is more accurate in pigmented tumors, and should be adopted for measuring the basal diameter of choroidal melanomas in planning treatment and follow-up.
- 1 June 2005
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 123 (6) , 868
Multilobular Choroidal Melanoma Following Ruthenium 106 Brachytherapy
- 1 June 2005
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 123 (6) , 868
Multilobular Choroidal Melanoma Following Ruthenium 106 Brachytherapy
- 1 February 2005
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 139 (2) , 229-234
The treatment of Primary Acquired Melanosis (PAM) with atypia by topical Mitomycin C
- 1 February 2005
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 139 (2) , 229-234
The treatment of Primary Acquired Melanosis (PAM) with atypia by topical Mitomycin C