Sabeen Askari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sabeen Askari has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Gayl Chrysler
From the Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, Minnesota; the Veterans Administration Medical Center, Minneapolis, Minnesota; and the American Red Cross Cord Blood Program, North Central Blood Services, St. Paul, Minnesota
2 shared publicationsJeffrey McCullough
From the Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, Minnesota; the Veterans Administration Medical Center, Minneapolis, Minnesota; and the American Red Cross Cord Blood Program, North Central Blood Services, St. Paul, Minnesota
2 shared publicationsJohn Miller
From the Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, Minnesota; the Veterans Administration Medical Center, Minneapolis, Minnesota; and the American Red Cross Cord Blood Program, North Central Blood Services, St. Paul, Minnesota
2 shared publicationsMary Clay
Department of Laboratory Medicine and Pathology and the Biomedical Engineering Institute, University of Minnesota Medical School, Minneapolis, Minnesota
1 shared publicationSheila Moran
Department of Laboratory Medicine and Pathology and the Biomedical Engineering Institute, University of Minnesota Medical School, Minneapolis, Minnesota
1 shared publication
Latest Publications
- 29 November 2010
- Published by Springer Nature
- p. 355-359
Donor and Collection-Related Variables Affecting Product Quality in Ex utero Cord Blood Banking
- 29 November 2010
- Published by Springer Nature
- p. 355-359
Donor and Collection-Related Variables Affecting Product Quality in Ex utero Cord Blood Banking
- 19 January 2005
- Published by Wiley in Transfusion
- Vol. 45 (2) , 189-194
Impact of donor‐ and collection‐related variables on product quality in ex utero cord blood banking
BACKGROUND: Optimizing product quality is a current focus in cord blood banking. This study evaluates the role of selected donor- and collection-related variables. STUDY DESIGN AND METHODS: Retrospective review was performed of cord blood units (CBUs) collected ex utero between February 1, 2000, and February 28, 2002. Preprocessing volume and total nucleated cell (TNC) counts and postprocessing CD34 cell counts were used as product quality indicators. RESULTS: Of 2084 CBUs, volume determinations and TNC counts were performed on 1628 and CD34+ counts on 1124 CBUs. Mean volume and TNC and CD34+ counts were 85.2 mL, 118.9 × 107, and 5.2 × 106, respectively. In univariate analysis, placental weight of greater than 500 g and meconium in amniotic fluid correlated with better volume and TNC and CD34+ counts. Greater than 40 weeks’ gestation predicted enhanced volume and TNC count. Cesarean section, two- versus one-person collection, and not greater than 5 minutes between placental delivery and collection produced superior volume. Increased TNC count was also seen in Caucasian women, primigravidae, female newborns, and collection duration of more than 5 minutes. A time between delivery of newborn and placenta of not greater than 10 minutes predicted better volume and CD34+ count. By regression analysis, collection within not greater than 5 minutes of placental delivery produced superior volume and TNC count. CONCLUSION: Donor selection and collection technique modifications may improve product quality. TNC count appears to be more affected by different variables than CD34+ count.
- 19 January 2005
- Published by Wiley in Transfusion
- Vol. 45 (2) , 189-194
Impact of donor‐ and collection‐related variables on product quality in ex utero cord blood banking
BACKGROUND: Optimizing product quality is a current focus in cord blood banking. This study evaluates the role of selected donor- and collection-related variables. STUDY DESIGN AND METHODS: Retrospective review was performed of cord blood units (CBUs) collected ex utero between February 1, 2000, and February 28, 2002. Preprocessing volume and total nucleated cell (TNC) counts and postprocessing CD34 cell counts were used as product quality indicators. RESULTS: Of 2084 CBUs, volume determinations and TNC counts were performed on 1628 and CD34+ counts on 1124 CBUs. Mean volume and TNC and CD34+ counts were 85.2 mL, 118.9 × 107, and 5.2 × 106, respectively. In univariate analysis, placental weight of greater than 500 g and meconium in amniotic fluid correlated with better volume and TNC and CD34+ counts. Greater than 40 weeks’ gestation predicted enhanced volume and TNC count. Cesarean section, two- versus one-person collection, and not greater than 5 minutes between placental delivery and collection produced superior volume. Increased TNC count was also seen in Caucasian women, primigravidae, female newborns, and collection duration of more than 5 minutes. A time between delivery of newborn and placenta of not greater than 10 minutes predicted better volume and CD34+ count. By regression analysis, collection within not greater than 5 minutes of placental delivery produced superior volume and TNC count. CONCLUSION: Donor selection and collection technique modifications may improve product quality. TNC count appears to be more affected by different variables than CD34+ count.
- 8 October 2002
- Published by Wiley in Transfusion
- Vol. 42 (10) , 1275-1278
The role of the paternal health history in cord blood banking
BACKGROUND : Umbilical cord blood (UCB) transplantation is becoming more widely used, yet ethical and policy issues regarding consent and health history persist. Whereas most UCB banks do not requir...
- 8 October 2002
- Published by Wiley in Transfusion
- Vol. 42 (10) , 1275-1278
The role of the paternal health history in cord blood banking
BACKGROUND : Umbilical cord blood (UCB) transplantation is becoming more widely used, yet ethical and policy issues regarding consent and health history persist. Whereas most UCB banks do not requir...