Paolo G. Camici
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Paolo G. Camici has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Adriaan A. Lammertsma
University Medical Center Groningen, University of Groningen
3 shared publications A. James Liedtke
1 shared publicationBruce E Keogh
1 shared publicationD Pagano
Cardiothoracic Surgical Unit, Queen Elizabeth Hospital, Birmingham, UK
1 shared publication- Durval Campos Costaa
Champalimaud Clinical Centre, Champalimaud Foundation , 1400-038 Lisbon
1 shared publication F Fath-Ordoubadi
MRC Cyclotron Unit and National Heart and Lung Institute, Imperial College School of Medicine, Hammersmith Hospital, Du Cane Road, London W12 0NN, UK
1 shared publication
Latest Publications
- 1 December 1999
- p. 783-6
The coronary microcirculation in left ventricular hypertrophy.
- Open Access
Efficacy of coronary angioplasty for the treatment of hibernating myocardium
OBJECTIVES: To determine the efficacy of coronary angioplasty as the sole method of revascularisation in patients with coronary artery disease and chronically dysfunctional but viable myocardium (hibernating myocardium), and to assess the effect of restenosis on functional outcome. DESIGN AND PATIENTS: 24 consecutive patients with hibernating myocardium were studied. Positron emission tomography was used to assess myocardial viability, blood flow, and flow reserve. One patient refused angioplasty, one had bypass surgery, and one died while waiting for an elective procedure. The procedure failed in three patients. The remaining 18 patients had repeat echocardiography, 15 had repeat coronary angiography, and nine had repeat assessments of blood flow and flow reserve at mean (SD) 17 (2) weeks after angioplasty. In three patients restenosis was documented. RESULTS: The wall motion score index in the revascularised territories improved from 1.71 (0.37) to 1.34 (0.47) (p = 0.008). Thirty of 51 dysfunctional segments improved in territories without restenosis compared with three of 14 in restenosed territories (p = 0.001). Hibernating and normal segments had comparable flows (0.82 (0.26) v0.89 (0.24) ml/min/g; NS) while flow reserve was lower in hibernating segments (1.55 (0.68) v 2.07 (1.08); p = 0.03). In segments without restenosis flow reserve improved from 2.03 (1.25) to 2.33 (1.4) (p = 0.03). Sensitivity, specificity, and positive and negative predictive accuracy of the viability study were 97%, 77%, 82%, and 96%, respectively. After excluding patients with restenosis, specificity and positive predictive accuracy improved to 90% and 93%. CONCLUSIONS: Angioplasty improves function in hibernating myocardium, and restenosis prevents recovery; hibernating myocardium is characterised by an impairment of flow reserve; restenosis affects the diagnostic accuracy of viability studies.
Open AccessEfficacy of coronary angioplasty for the treatment of hibernating myocardium
OBJECTIVES: To determine the efficacy of coronary angioplasty as the sole method of revascularisation in patients with coronary artery disease and chronically dysfunctional but viable myocardium (hibernating myocardium), and to assess the effect of restenosis on functional outcome. DESIGN AND PATIENTS: 24 consecutive patients with hibernating myocardium were studied. Positron emission tomography was used to assess myocardial viability, blood flow, and flow reserve. One patient refused angioplasty, one had bypass surgery, and one died while waiting for an elective procedure. The procedure failed in three patients. The remaining 18 patients had repeat echocardiography, 15 had repeat coronary angiography, and nine had repeat assessments of blood flow and flow reserve at mean (SD) 17 (2) weeks after angioplasty. In three patients restenosis was documented. RESULTS: The wall motion score index in the revascularised territories improved from 1.71 (0.37) to 1.34 (0.47) (p = 0.008). Thirty of 51 dysfunctional segments improved in territories without restenosis compared with three of 14 in restenosed territories (p = 0.001). Hibernating and normal segments had comparable flows (0.82 (0.26) v0.89 (0.24) ml/min/g; NS) while flow reserve was lower in hibernating segments (1.55 (0.68) v 2.07 (1.08); p = 0.03). In segments without restenosis flow reserve improved from 2.03 (1.25) to 2.33 (1.4) (p = 0.03). Sensitivity, specificity, and positive and negative predictive accuracy of the viability study were 97%, 77%, 82%, and 96%, respectively. After excluding patients with restenosis, specificity and positive predictive accuracy improved to 90% and 93%. CONCLUSIONS: Angioplasty improves function in hibernating myocardium, and restenosis prevents recovery; hibernating myocardium is characterised by an impairment of flow reserve; restenosis affects the diagnostic accuracy of viability studies.
- 1 February 1999
- Published by Springer Nature in Basic Research in Cardiology
- Vol. 94 (1) , 49-59
Transmural myocardial blood flow distribution in hypertrophic cardiomyopathy and effect of treatment
Verapamil alleviates symptoms in patients with hypertrophic cardiomyopathy (HCM), but the underlying mechanism of improvement remains speculative. Baseline and dipyridamole myocardial blood flow (MBF) were measured in 15 HCM patients (14 men, 42±10 years), before and after 4 weeks of verapamil SR 480 mg daily, using 15O labelled water and positron emission tomography (PET). Subendocardial (endo) and subpericardial (epi) MBF was measured in the septum (thickness 25.4±5.8 mm). Pre-treatment baseline whole heart MBF was 1.02±0.28 ml/min/g and 1.01±0.30 ml/min/g on treatment (p=ns). Dipyridamole MBF was 1.39±0.31 ml/min/g off treatment and 1.23±0.34 ml/min/g on treatment (p=ns). Coronary flow reserve (dipyridamole/resting MBF) was 1.45±0.52 and 1.30±0.51, respectively (p=ns). At baseline, the septal endo/epi MBF ratio was uniform off and on treatment (1.13±0.18 vs 1.18±0.21, p=ns). Before treatment, the endo/epi ratio following dipyridamole decreased to 0.93±0.24 (pin vivo in patients with hypertrophied ventricles. Despite symptomatic improvement, high dose verapamil therapy does not increase total MBF in patients with HCM but may improve septal transmural MBF distribution during dipyridamole in some patients.
- 1 February 1999
- Published by Springer Nature in Basic Research in Cardiology
- Vol. 94 (1) , 49-59
Transmural myocardial blood flow distribution in hypertrophic cardiomyopathy and effect of treatment
Verapamil alleviates symptoms in patients with hypertrophic cardiomyopathy (HCM), but the underlying mechanism of improvement remains speculative. Baseline and dipyridamole myocardial blood flow (MBF) were measured in 15 HCM patients (14 men, 42±10 years), before and after 4 weeks of verapamil SR 480 mg daily, using 15O labelled water and positron emission tomography (PET). Subendocardial (endo) and subpericardial (epi) MBF was measured in the septum (thickness 25.4±5.8 mm). Pre-treatment baseline whole heart MBF was 1.02±0.28 ml/min/g and 1.01±0.30 ml/min/g on treatment (p=ns). Dipyridamole MBF was 1.39±0.31 ml/min/g off treatment and 1.23±0.34 ml/min/g on treatment (p=ns). Coronary flow reserve (dipyridamole/resting MBF) was 1.45±0.52 and 1.30±0.51, respectively (p=ns). At baseline, the septal endo/epi MBF ratio was uniform off and on treatment (1.13±0.18 vs 1.18±0.21, p=ns). Before treatment, the endo/epi ratio following dipyridamole decreased to 0.93±0.24 (pin vivo in patients with hypertrophied ventricles. Despite symptomatic improvement, high dose verapamil therapy does not increase total MBF in patients with HCM but may improve septal transmural MBF distribution during dipyridamole in some patients.
- Open Access
Predictive value of dobutamine echocardiography and positron emission tomography in identifying hibernating myocardium in patients with postischaemic heart failure
Objective: To compare the predictive value of dobutamine echocardiography (DE) and positron emission tomography (PET) in identifying reversible chronic left ventricular (LV) dysfunction (hibernating myocardium) in patients with coronary artery disease (CAD) and overt heart failure. Patients: 30 patients (four women) with CAD and heart failure undergoing coronary artery bypass grafting (CABG). Methods: Myocardial viability was assessed with DE (5 and 10 μg/kg/min) and PET with [18F] 2-fluoro-2-deoxy-D-glucose (FDG) under hyperinsulinaemic euglycaemic clamp. Regional (echo) and global LV function (MUGA) were assessed at baseline and six months after CABG. Results: 192 of the 336 (57%) dysfunctional LV segments improved function following CABG (hibernating) and the LV ejection fraction (EF) increased from 23(7) to 32(9)% (p < 0.0001) (in 17 patients > 5%). DE and PET had similar positive predictive values (68% and 66%) in the identification of hibernating myocardium, but DE had a significantly lower negative predictive value than PET (54% v 96%; p < 0.0001). A significant linear correlation was found between the number of PET viable segments and the changes in EF following CABG (r = 0.65; p = 0.0001). Stepwise logistic regression identified the number of PET viable segments as an independent predictor of improvement in EF > 5%, whereas the number of DE viable segments, the baseline LVEF, and wall motion were not. Conclusions: DE has a higher false negative rate than PET in identifying recoverable LV dysfunction in patients with severe postischaemic heart failure. The amount of PET viable myocardium correlates with the functional outcome following CABG.
Open AccessPredictive value of dobutamine echocardiography and positron emission tomography in identifying hibernating myocardium in patients with postischaemic heart failure
Objective: To compare the predictive value of dobutamine echocardiography (DE) and positron emission tomography (PET) in identifying reversible chronic left ventricular (LV) dysfunction (hibernating myocardium) in patients with coronary artery disease (CAD) and overt heart failure. Patients: 30 patients (four women) with CAD and heart failure undergoing coronary artery bypass grafting (CABG). Methods: Myocardial viability was assessed with DE (5 and 10 μg/kg/min) and PET with [18F] 2-fluoro-2-deoxy-D-glucose (FDG) under hyperinsulinaemic euglycaemic clamp. Regional (echo) and global LV function (MUGA) were assessed at baseline and six months after CABG. Results: 192 of the 336 (57%) dysfunctional LV segments improved function following CABG (hibernating) and the LV ejection fraction (EF) increased from 23(7) to 32(9)% (p < 0.0001) (in 17 patients > 5%). DE and PET had similar positive predictive values (68% and 66%) in the identification of hibernating myocardium, but DE had a significantly lower negative predictive value than PET (54% v 96%; p < 0.0001). A significant linear correlation was found between the number of PET viable segments and the changes in EF following CABG (r = 0.65; p = 0.0001). Stepwise logistic regression identified the number of PET viable segments as an independent predictor of improvement in EF > 5%, whereas the number of DE viable segments, the baseline LVEF, and wall motion were not. Conclusions: DE has a higher false negative rate than PET in identifying recoverable LV dysfunction in patients with severe postischaemic heart failure. The amount of PET viable myocardium correlates with the functional outcome following CABG.
- 1 March 1998
- Vol. 3 (1) , 31-8
Positron emission tomography to assess the haemodynamics of the coronary circulation.
Positron emission tomography (PET) allows the non-invasive measurement of absolute myocardial blood flow (ml/min/g of myocardium) in man. This has made possible the measurement of myocardial blood flow and the coronary vasodilator reserve (an index of the ability of the coronary microcirculation to dilate) in healthy volunteers to establish the normal values and ranges of these parameters. This technique allows the assessment of the functional significance of epicardial coronary stenoses as well as the investigation of the function of the coronary microcirculation in patients with and without coronary artery disease.
- 1 March 1998
- Vol. 3 (1) , 31-8
Positron emission tomography to assess the haemodynamics of the coronary circulation.
Positron emission tomography (PET) allows the non-invasive measurement of absolute myocardial blood flow (ml/min/g of myocardium) in man. This has made possible the measurement of myocardial blood flow and the coronary vasodilator reserve (an index of the ability of the coronary microcirculation to dilate) in healthy volunteers to establish the normal values and ranges of these parameters. This technique allows the assessment of the functional significance of epicardial coronary stenoses as well as the investigation of the function of the coronary microcirculation in patients with and without coronary artery disease.
- 4 November 1997
- Published by Wolters Kluwer Health in Circulation
- Vol. 96 (9) , 3205-3214
Pathophysiological Mechanisms of Chronic Reversible Left Ventricular Dysfunction due to Coronary Artery Disease (Hibernating Myocardium)
- 4 November 1997
- Published by Wolters Kluwer Health in Circulation
- Vol. 96 (9) , 3205-3214
Pathophysiological Mechanisms of Chronic Reversible Left Ventricular Dysfunction due to Coronary Artery Disease (Hibernating Myocardium)
- 30 April 1995
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 2 (2) , S3
The pathophysiology of hibernating myocardium studied by PET during hyperinsulinemic-euglycemic clamp
- 30 April 1995
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 2 (2) , S3
The pathophysiology of hibernating myocardium studied by PET during hyperinsulinemic-euglycemic clamp