Carl L. Hansen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Carl L. Hansen has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Michael VanInsberghe
Centre for High-Throughput Biology, University of British Columbia, Vancouver, BC, Canada
3 shared publicationsDavid Walker
Centre for High-Throughput Biology, University of British Columbia, Vancouver, British Columbia, Canada
2 shared publicationsHans Zahn
Centre for High-Throughput Biology, University of British Columbia, Vancouver, BC, Canada
2 shared publicationsKevin A. Heyries
Centre for High-Throughput Biology, University of British Columbia, Vancouver, British Columbia, Canada
2 shared publicationsMani Hamidi
Centre for High-Throughput Biology and
2 shared publicationsOleh I. Petriv
Centre for High-Throughput Biology, University of British Columbia, Vancouver, British Columbia, Canada
2 shared publications
Latest Publications
- 9 June 2015
- Published by Wiley in Biotechnology Journal
- Vol. 10 (10) , 1546-1554
Clonal analysis of individual human embryonic stem cell differentiation patterns in microfluidic cultures
Heterogeneity in the clonal outputs of individual human embryonic stem cells (hESCs) confounds analysis of their properties in studies of bulk populations and how to manipulate them for clinical applications. To circumvent this problem we developed a microfluidic device that supports the robust generation of colonies derived from single ESCs. This microfluidic system contains 160 individually addressable chambers equipped for perfusion culture of individual hESCs that could be shown to match the growth rates, marker expression and colony morphologies obtained in conventional cultures. Use of this microfluidic device to analyze the clonal growth kinetics of multiple individual hESCs induced to differentiation revealed variable shifts in the growth rate, area per cell and expression of OCT4 in the progeny of individual hESCs. Interestingly, low OCT4 expression, a slower growth rate and low nuclear to cytoplasmic ratios were found to be correlated responses. This study demonstrates how microfluidic systems can be used to enable large scale live‐cell imaging of isolated hESCs exposed to changing culture conditions, to examine how different aspects of their variable responses are correlated.
- 9 June 2015
- Published by Wiley in Biotechnology Journal
- Vol. 10 (10) , 1546-1554
Clonal analysis of individual human embryonic stem cell differentiation patterns in microfluidic cultures
Heterogeneity in the clonal outputs of individual human embryonic stem cells (hESCs) confounds analysis of their properties in studies of bulk populations and how to manipulate them for clinical applications. To circumvent this problem we developed a microfluidic device that supports the robust generation of colonies derived from single ESCs. This microfluidic system contains 160 individually addressable chambers equipped for perfusion culture of individual hESCs that could be shown to match the growth rates, marker expression and colony morphologies obtained in conventional cultures. Use of this microfluidic device to analyze the clonal growth kinetics of multiple individual hESCs induced to differentiation revealed variable shifts in the growth rate, area per cell and expression of OCT4 in the progeny of individual hESCs. Interestingly, low OCT4 expression, a slower growth rate and low nuclear to cytoplasmic ratios were found to be correlated responses. This study demonstrates how microfluidic systems can be used to enable large scale live‐cell imaging of isolated hESCs exposed to changing culture conditions, to examine how different aspects of their variable responses are correlated.
- Open Access
- 22 May 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (5) , e98341
Methods for Multiplex Template Sampling in Digital PCR Assays
The efficient use of digital PCR (dPCR) for precision copy number analysis requires high concentrations of target molecules that may be difficult or impossible to obtain from clinical samples. To solve this problem we present a strategy, called Multiplex Template Sampling (MTS), that effectively increases template concentrations by detecting multiple regions of fragmented target molecules. Three alternative assay approaches are presented for implementing MTS analysis of chromosome 21, providing a 10-fold concentration enhancement while preserving assay precision.
- 22 May 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (5) , e98341
Open AccessMethods for Multiplex Template Sampling in Digital PCR Assays
The efficient use of digital PCR (dPCR) for precision copy number analysis requires high concentrations of target molecules that may be difficult or impossible to obtain from clinical samples. To solve this problem we present a strategy, called Multiplex Template Sampling (MTS), that effectively increases template concentrations by detecting multiple regions of fragmented target molecules. Three alternative assay approaches are presented for implementing MTS analysis of chromosome 21, providing a 10-fold concentration enhancement while preserving assay precision.
- Open Access
- 26 June 2013
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 110 (28) , 11403-11408
Dissecting genealogy and cell cycle as sources of cell-to-cell variability in MAPK signaling using high-throughput lineage tracking
Cells, even those having identical genotype, exhibit variability in their response to external stimuli. This variability arises from differences in the abundance, localization, and state of cellular components. Such nongenetic differences are likely heritable between successive generations and can also be influenced by processes such as cell cycle, age, or interplay between different pathways. To address the contribution of nongenetic heritability and cell cycle in cell-to-cell variability we developed a high-throughput and fully automated microfluidic platform that allows for concurrent measurement of gene expression, cell-cycle periods, age, and lineage information under a large number of temporally changing medium conditions and using multiple strains. We apply this technology to examine the role of nongenetic inheritance in cell heterogeneity of yeast pheromone signaling. Our data demonstrate that the capacity to respond to pheromone is passed across generations and that the strength of the response correlations between related cells is affected by perturbations in the signaling pathway. We observe that a ste50Δ mutant strain exhibits highly heterogeneous response to pheromone originating from a unique asymmetry between mother and daughter response. On the other hand, fus3Δ cells were found to exhibit an unusually high correlation between mother and daughter cells that arose from a combination of extended cell-cycle periods of fus3Δ mothers, and decreased cell-cycle modulation of the pheromone pathway. Our results contribute to the understanding of the origins of cell heterogeneity and demonstrate the importance of automated platforms that generate single-cell data on several parameters.
- 26 June 2013
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 110 (28) , 11403-11408
Open AccessDissecting genealogy and cell cycle as sources of cell-to-cell variability in MAPK signaling using high-throughput lineage tracking
Cells, even those having identical genotype, exhibit variability in their response to external stimuli. This variability arises from differences in the abundance, localization, and state of cellular components. Such nongenetic differences are likely heritable between successive generations and can also be influenced by processes such as cell cycle, age, or interplay between different pathways. To address the contribution of nongenetic heritability and cell cycle in cell-to-cell variability we developed a high-throughput and fully automated microfluidic platform that allows for concurrent measurement of gene expression, cell-cycle periods, age, and lineage information under a large number of temporally changing medium conditions and using multiple strains. We apply this technology to examine the role of nongenetic inheritance in cell heterogeneity of yeast pheromone signaling. Our data demonstrate that the capacity to respond to pheromone is passed across generations and that the strength of the response correlations between related cells is affected by perturbations in the signaling pathway. We observe that a ste50Δ mutant strain exhibits highly heterogeneous response to pheromone originating from a unique asymmetry between mother and daughter response. On the other hand, fus3Δ cells were found to exhibit an unusually high correlation between mother and daughter cells that arose from a combination of extended cell-cycle periods of fus3Δ mothers, and decreased cell-cycle modulation of the pheromone pathway. Our results contribute to the understanding of the origins of cell heterogeneity and demonstrate the importance of automated platforms that generate single-cell data on several parameters.
- 30 April 2012
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 109 (20) , 7665-7670
A programmable droplet-based microfluidic device applied to multiparameter analysis of single microbes and microbial communities
We present a programmable droplet-based microfluidic device that combines the reconfigurable flow-routing capabilities of integrated microvalve technology with the sample compartmentalization and dispersion-free transport that is inherent to droplets. The device allows for the execution of user-defined multistep reaction protocols in 95 individually addressable nanoliter-volume storage chambers by consecutively merging programmable sequences of picoliter-volume droplets containing reagents or cells. This functionality is enabled by “flow-controlled wetting,” a droplet docking and merging mechanism that exploits the physics of droplet flow through a channel to control the precise location of droplet wetting. The device also allows for automated cross-contamination-free recovery of reaction products from individual chambers into standard microfuge tubes for downstream analysis. The combined features of programmability, addressability, and selective recovery provide a general hardware platform that can be reprogrammed for multiple applications. We demonstrate this versatility by implementing multiple single-cell experiment types with this device: bacterial cell sorting and cultivation, taxonomic gene identification, and high-throughput single-cell whole genome amplification and sequencing using common laboratory strains. Finally, we apply the device to genome analysis of single cells and microbial consortia from diverse environmental samples including a marine enrichment culture, deep-sea sediments, and the human oral cavity. The resulting datasets capture genotypic properties of individual cells and illuminate known and potentially unique partnerships between microbial community members.
- 30 April 2012
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 109 (20) , 7665-7670
A programmable droplet-based microfluidic device applied to multiparameter analysis of single microbes and microbial communities
We present a programmable droplet-based microfluidic device that combines the reconfigurable flow-routing capabilities of integrated microvalve technology with the sample compartmentalization and dispersion-free transport that is inherent to droplets. The device allows for the execution of user-defined multistep reaction protocols in 95 individually addressable nanoliter-volume storage chambers by consecutively merging programmable sequences of picoliter-volume droplets containing reagents or cells. This functionality is enabled by “flow-controlled wetting,” a droplet docking and merging mechanism that exploits the physics of droplet flow through a channel to control the precise location of droplet wetting. The device also allows for automated cross-contamination-free recovery of reaction products from individual chambers into standard microfuge tubes for downstream analysis. The combined features of programmability, addressability, and selective recovery provide a general hardware platform that can be reprogrammed for multiple applications. We demonstrate this versatility by implementing multiple single-cell experiment types with this device: bacterial cell sorting and cultivation, taxonomic gene identification, and high-throughput single-cell whole genome amplification and sequencing using common laboratory strains. Finally, we apply the device to genome analysis of single cells and microbial consortia from diverse environmental samples including a marine enrichment culture, deep-sea sediments, and the human oral cavity. The resulting datasets capture genotypic properties of individual cells and illuminate known and potentially unique partnerships between microbial community members.
- 13 October 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (23) , 4122-4125
Parylene C coating for high-performance replica molding
This paper presents an improvement to the soft lithography fabrication process that uses chemical vapor deposition of poly(chloro-p-xylylene) (parylene C) to protect microfabricated masters and to improve the release of polymer devices following replica molding. Chemical vapor deposition creates nanometre thick conformal coatings of parylene C on silicon wafers having arrays of 30 μm high SU8 pillars with densities ranging from 278 to 10,040 features per mm2 and aspect ratios (height : width) from 1 : 1 to 6 : 1. A single coating of parylene C was sufficient to permanently promote poly(dimethyl)siloxane (PDMS) mold release and to protect masters for an indefinite number of molding cycles. We also show that the improved release properties of parylene treated masters allow for fabrication with hard polymers, such as poly(urethane), that would otherwise not be compatible with SU8 on silicon masters. Parylene C provides a robust and high performance mold release coating for soft lithography microfabrication that extends the life of microfabricated masters and improves the achievable density and aspect ratio of replicated features.
- 13 October 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (23) , 4122-4125
Parylene C coating for high-performance replica molding
This paper presents an improvement to the soft lithography fabrication process that uses chemical vapor deposition of poly(chloro-p-xylylene) (parylene C) to protect microfabricated masters and to improve the release of polymer devices following replica molding. Chemical vapor deposition creates nanometre thick conformal coatings of parylene C on silicon wafers having arrays of 30 μm high SU8 pillars with densities ranging from 278 to 10,040 features per mm2 and aspect ratios (height : width) from 1 : 1 to 6 : 1. A single coating of parylene C was sufficient to permanently promote poly(dimethyl)siloxane (PDMS) mold release and to protect masters for an indefinite number of molding cycles. We also show that the improved release properties of parylene treated masters allow for fabrication with hard polymers, such as poly(urethane), that would otherwise not be compatible with SU8 on silicon masters. Parylene C provides a robust and high performance mold release coating for soft lithography microfabrication that extends the life of microfabricated masters and improves the achievable density and aspect ratio of replicated features.
- Top Cited PapersOpen Access
- 23 August 2011
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 108 (34) , 13999-14004
High-throughput microfluidic single-cell RT-qPCR
A long-sought milestone in microfluidics research has been the development of integrated technology for scalable analysis of transcription in single cells. Here we present a fully integrated microfluidic device capable of performing high-precision RT-qPCR measurements of gene expression from hundreds of single cells per run. Our device executes all steps of single-cell processing, including cell capture, cell lysis, reverse transcription, and quantitative PCR. In addition to higher throughput and reduced cost, we show that nanoliter volume processing reduced measurement noise, increased sensitivity, and provided single nucleotide specificity. We apply this technology to 3,300 single-cell measurements of ( i ) miRNA expression in K562 cells, ( ii ) coregulation of a miRNA and one of its target transcripts during differentiation in embryonic stem cells, and ( iii ) single nucleotide variant detection in primary lobular breast cancer cells. The core functionality established here provides the foundation from which a variety of on-chip single-cell transcription analyses will be developed.
- 23 August 2011
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 108 (34) , 13999-14004
Top Cited PapersOpen AccessHigh-throughput microfluidic single-cell RT-qPCR
A long-sought milestone in microfluidics research has been the development of integrated technology for scalable analysis of transcription in single cells. Here we present a fully integrated microfluidic device capable of performing high-precision RT-qPCR measurements of gene expression from hundreds of single cells per run. Our device executes all steps of single-cell processing, including cell capture, cell lysis, reverse transcription, and quantitative PCR. In addition to higher throughput and reduced cost, we show that nanoliter volume processing reduced measurement noise, increased sensitivity, and provided single nucleotide specificity. We apply this technology to 3,300 single-cell measurements of ( i ) miRNA expression in K562 cells, ( ii ) coregulation of a miRNA and one of its target transcripts during differentiation in embryonic stem cells, and ( iii ) single nucleotide variant detection in primary lobular breast cancer cells. The core functionality established here provides the foundation from which a variety of on-chip single-cell transcription analyses will be developed.
- 18 November 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (3) , 466-473
High-throughput tracking of single yeast cells in a microfluidic imaging matrix
Time-lapse live cell imaging is a powerful tool for studying signaling network dynamics and complexity and is uniquely suited to single cell studies of response dynamics, noise, and heritable differences. Although conventional imaging formats have the temporal and spatial resolution needed for such studies, they do not provide the simultaneous advantages of cell tracking, experimental throughput, and precise chemical control. This is particularly problematic for system-level studies using non-adherent model organisms such as yeast, where the motion of cells complicates tracking and where large-scale analysis under a variety of genetic and chemical perturbations is desired. We present here a high-throughput microfluidic imaging system capable of tracking single cells over multiple generations in 128 simultaneous experiments with programmable and precise chemical control. High-resolution imaging and robust cell tracking are achieved through immobilization of yeast cells using a combination of mechanical clamping and polymerization in an agarose gel. The channel and valve architecture of our device allows for the formation of a matrix of 128 integrated agarose gel pads, each allowing for an independent imaging experiment with fully programmable medium exchange via diffusion. We demonstrate our system in the combinatorial and quantitative analysis of the yeast pheromone signaling response across 8 genotypes and 16 conditions, and show that lineage-dependent effects contribute to observed variability at stimulation conditions near the critical threshold for cellular decision making.
- 18 November 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (3) , 466-473
High-throughput tracking of single yeast cells in a microfluidic imaging matrix
Time-lapse live cell imaging is a powerful tool for studying signaling network dynamics and complexity and is uniquely suited to single cell studies of response dynamics, noise, and heritable differences. Although conventional imaging formats have the temporal and spatial resolution needed for such studies, they do not provide the simultaneous advantages of cell tracking, experimental throughput, and precise chemical control. This is particularly problematic for system-level studies using non-adherent model organisms such as yeast, where the motion of cells complicates tracking and where large-scale analysis under a variety of genetic and chemical perturbations is desired. We present here a high-throughput microfluidic imaging system capable of tracking single cells over multiple generations in 128 simultaneous experiments with programmable and precise chemical control. High-resolution imaging and robust cell tracking are achieved through immobilization of yeast cells using a combination of mechanical clamping and polymerization in an agarose gel. The channel and valve architecture of our device allows for the formation of a matrix of 128 integrated agarose gel pads, each allowing for an independent imaging experiment with fully programmable medium exchange via diffusion. We demonstrate our system in the combinatorial and quantitative analysis of the yeast pheromone signaling response across 8 genotypes and 16 conditions, and show that lineage-dependent effects contribute to observed variability at stimulation conditions near the critical threshold for cellular decision making.
- 11 June 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 10 (18) , 2358-2365
Three-dimensional large-scale microfluidic integration by laser ablation of interlayer connections
Multilayer Soft Lithography (MSL) is a robust and mature fabrication technique for the rapid prototyping of microfluidic circuits having thousands of integrated valves. Despite the success and wide application of this method, it is fundamentally a planar fabrication technique which imposes serious design constraints on channel routing, feature density, and fluid handling complexity. We present here methods and related instrumentation to remove these limitations by combining the advantages of MSL processing with laser micromachining using a CO2 laser ablation system. This system is applied to both the dense integration of layer–layer interconnects and the direct writing of microchannels. Real-time image recognition and computer control allow for robust wafer-scale registration of laser ablation features with moulded channel structures. Ablation rates of up to 8 Hz are achieved with positional accuracy of ∼20 µm independent of mechanical distortions in the elastomer substrate. We demonstrate these capabilities in the design and fabrication of a production scale multi-laminate micromixer that achieves sub-millisecond mixing of two streams at flow rates up to 1 mL min−1. The marriage of laser micromachining with MSL-based valve integration allows for high-yield fabrication of topologically complex microfluidic circuits having thousands of layer–layer interconnects and integrated valves.
- 11 June 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 10 (18) , 2358-2365
Three-dimensional large-scale microfluidic integration by laser ablation of interlayer connections
Multilayer Soft Lithography (MSL) is a robust and mature fabrication technique for the rapid prototyping of microfluidic circuits having thousands of integrated valves. Despite the success and wide application of this method, it is fundamentally a planar fabrication technique which imposes serious design constraints on channel routing, feature density, and fluid handling complexity. We present here methods and related instrumentation to remove these limitations by combining the advantages of MSL processing with laser micromachining using a CO2 laser ablation system. This system is applied to both the dense integration of layer–layer interconnects and the direct writing of microchannels. Real-time image recognition and computer control allow for robust wafer-scale registration of laser ablation features with moulded channel structures. Ablation rates of up to 8 Hz are achieved with positional accuracy of ∼20 µm independent of mechanical distortions in the elastomer substrate. We demonstrate these capabilities in the design and fabrication of a production scale multi-laminate micromixer that achieves sub-millisecond mixing of two streams at flow rates up to 1 mL min−1. The marriage of laser micromachining with MSL-based valve integration allows for high-yield fabrication of topologically complex microfluidic circuits having thousands of layer–layer interconnects and integrated valves.