Eric E. Klein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eric E. Klein has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Bhudatt Paliwal
2 shared publications- Charles Bloch
Indiana University Cyclotron Facility, Bloomington, Indiana 47405
2 shared publications - Daniel A. Low
Washington University School of Medicine, St. Louis, Missouri 63110, USA
2 shared publications - Issam El Naqa
Department of Machine Learning, Moffitt Cancer Center, Tampa, FL, United States
2 shared publications - Lakshmi Santanam
Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110
2 shared publications - Lesley Hughes
Department of Biological Sciences Macquarie University North Ryde NSW Australia
2 shared publications
Latest Publications
- 4 December 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (24) , 8709-8723
Evaluation of neutron dose equivalent from the Mevion S250 proton accelerator: measurements and calculations
Neutron production is of concern for proton therapy, especially for passive scattering proton beam delivery methods. The levels of neutron dose equivalent vary significantly with system design and treatment parameters. The purpose of this study was to examine neutron dose equivalent per therapeutic dose (H/D) around the Mevion S250 proton therapy system, a novel design of proton therapy systems. The benchmark comparisons between measurement and simulation were found to be within a factor of 2 for most cases. The H/D values were evaluated as a function of various parameters. The results showed that, at a standard reference condition (10 × 10 cm2 field size, distance 1 m detector-to-isocenter lateral to the primary proton beam direction), the H/D values range from 0.72 to 3.37 mSv Gy−1 for all configurations studied. The H/D values generally (1) decreased as the neutron detectors moved away from the isocenter, (2) decreased with increasing aperture field sizes, (3) increased with increasing angle from the initial beam axis and (4) were independent of treatment nozzle position. The H/D trends were consistent with other existing passive scattering proton accelerators reported in the literature.
- 4 December 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (24) , 8709-8723
Evaluation of neutron dose equivalent from the Mevion S250 proton accelerator: measurements and calculations
Neutron production is of concern for proton therapy, especially for passive scattering proton beam delivery methods. The levels of neutron dose equivalent vary significantly with system design and treatment parameters. The purpose of this study was to examine neutron dose equivalent per therapeutic dose (H/D) around the Mevion S250 proton therapy system, a novel design of proton therapy systems. The benchmark comparisons between measurement and simulation were found to be within a factor of 2 for most cases. The H/D values were evaluated as a function of various parameters. The results showed that, at a standard reference condition (10 × 10 cm2 field size, distance 1 m detector-to-isocenter lateral to the primary proton beam direction), the H/D values range from 0.72 to 3.37 mSv Gy−1 for all configurations studied. The H/D values generally (1) decreased as the neutron detectors moved away from the isocenter, (2) decreased with increasing aperture field sizes, (3) increased with increasing angle from the initial beam axis and (4) were independent of treatment nozzle position. The H/D trends were consistent with other existing passive scattering proton accelerators reported in the literature.
- 24 July 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (16) , 5527-5539
Optimizing field patching in passively scattered proton therapy with the use of beam current modulation
Treatment plans for patched-field proton therapy may not be clinically acceptable due to the dose heterogeneity introduced in the target when combining the dose distributions from two separate fields. MCNPX simulations were performed for various configurations of the Mevion S250 beamline to determine spread-out Bragg peak dose distributions and patched-field treatment plans delivered using a rotating modulator wheel to depths in the clinically relevant range between 5.0 and 30.0 cm. The dose non-uniformity (DNU) metric was defined as the difference between the maximum and minimum dose relative to the prescription observed in a patched dose distribution. The DNU was first evaluated for dose distributions from a standard delivery using constant beam current and combining through-field lateral dose profiles and with patch-field distal dose profiles. Patch-field distal dose profiles were then optimized using beam current modulation in an attempt to better complement the through-field lateral dose profiles when combined into a patched dose distribution. Using standard deliveries, DNU was 10% or less only when patching lateral profiles 12.5–17.5 cm deep. Significantly greater DNU was observed for patches outside of this range, at times exceeding 35%. Using optimized distal profiles, DNU was reduced to 10% or less for all lateral profiles deeper than 15.0 cm. Optimizing beam current modulation was found to create distal profiles with more gradual dose falloff than found in a standard delivery, allowing optimized distal dose distributions to sum more homogeneously with lateral dose distributions. The hot or cold spots that often appear in patched dose distributions from standard deliveries may therefore be mitigated by optimizing beam current. This method may also be applied to systems other than the Mevion system to further improve patched-field dose homogeneity.
- 24 July 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (16) , 5527-5539
Optimizing field patching in passively scattered proton therapy with the use of beam current modulation
Treatment plans for patched-field proton therapy may not be clinically acceptable due to the dose heterogeneity introduced in the target when combining the dose distributions from two separate fields. MCNPX simulations were performed for various configurations of the Mevion S250 beamline to determine spread-out Bragg peak dose distributions and patched-field treatment plans delivered using a rotating modulator wheel to depths in the clinically relevant range between 5.0 and 30.0 cm. The dose non-uniformity (DNU) metric was defined as the difference between the maximum and minimum dose relative to the prescription observed in a patched dose distribution. The DNU was first evaluated for dose distributions from a standard delivery using constant beam current and combining through-field lateral dose profiles and with patch-field distal dose profiles. Patch-field distal dose profiles were then optimized using beam current modulation in an attempt to better complement the through-field lateral dose profiles when combined into a patched dose distribution. Using standard deliveries, DNU was 10% or less only when patching lateral profiles 12.5–17.5 cm deep. Significantly greater DNU was observed for patches outside of this range, at times exceeding 35%. Using optimized distal profiles, DNU was reduced to 10% or less for all lateral profiles deeper than 15.0 cm. Optimizing beam current modulation was found to create distal profiles with more gradual dose falloff than found in a standard delivery, allowing optimized distal dose distributions to sum more homogeneously with lateral dose distributions. The hot or cold spots that often appear in patched dose distributions from standard deliveries may therefore be mitigated by optimizing beam current. This method may also be applied to systems other than the Mevion system to further improve patched-field dose homogeneity.
- Open Access
- 1 November 2011
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 81 (4) , 1190-1192
The American Society for Radiation Oncology’s 2010 Core Physics Curriculum for Radiation Oncology Residents
- 1 November 2011
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 81 (4) , 1190-1192
Open AccessThe American Society for Radiation Oncology’s 2010 Core Physics Curriculum for Radiation Oncology Residents
- Open Access
- 3 December 2009
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 11 (1) , 263-273
A grid to facilitate physics staffing justification
Justification of clinical physics staffing levels is difficult due to the lack of direction as how to equate clinical needs with the staffing levels and competency required. When a physicist negotiates staffing requests to administration, she/he often refers to American College of Radiology staffing level suggestions, and resources such as the Abt studies. This approach is often met with questions as to how to fairly derive the time it takes to perform tasks. The result is often insufficient and/or inexperienced staff handling complex and cumbersome tasks. We undertook development of a staffing justification grid to equate the clinical needs to the quantity and quality of staffing required. The first step is using the Abt study, customized to the clinical setting, to derive time per task multiplied by the anticipated number of such tasks. Inclusion of vacation, meeting, and developmental time may be incorporated along with allocated time for education and administration. This is followed by mapping the tasks to the level of competency/experience needed. For example, in an academic setting the faculty appointment levels correlate with experience. Non‐staff personnel, such as IMRT QA technicians or clerical staff, should also be part of the equation. By using the staffing justification grid, we derived strong documentation to justify a substantial budget increase. The grid also proved useful when our clinical demands changed. Justification for physics staffing can be significantly strengthened with a properly developed data‐based time and work analysis. A staffing grid is presented, along with a development methodology that facilitated our justification. Though our grid is for a large academic facility, the methodology can be extended to a non‐academic setting, and to a smaller scale. This grid method not only equates the clinical needs with the quantity of staffing, but can also help generate the personnel budget, based on the type of staff and personnel required. The grid is easily adaptable when changes to the clinical environment change, such as an increase in IMRT or IGRT applications. PACS number: 87.55.tm, 87.55.Qr
- 3 December 2009
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 11 (1) , 263-273
Open AccessA grid to facilitate physics staffing justification
Justification of clinical physics staffing levels is difficult due to the lack of direction as how to equate clinical needs with the staffing levels and competency required. When a physicist negotiates staffing requests to administration, she/he often refers to American College of Radiology staffing level suggestions, and resources such as the Abt studies. This approach is often met with questions as to how to fairly derive the time it takes to perform tasks. The result is often insufficient and/or inexperienced staff handling complex and cumbersome tasks. We undertook development of a staffing justification grid to equate the clinical needs to the quantity and quality of staffing required. The first step is using the Abt study, customized to the clinical setting, to derive time per task multiplied by the anticipated number of such tasks. Inclusion of vacation, meeting, and developmental time may be incorporated along with allocated time for education and administration. This is followed by mapping the tasks to the level of competency/experience needed. For example, in an academic setting the faculty appointment levels correlate with experience. Non‐staff personnel, such as IMRT QA technicians or clerical staff, should also be part of the equation. By using the staffing justification grid, we derived strong documentation to justify a substantial budget increase. The grid also proved useful when our clinical demands changed. Justification for physics staffing can be significantly strengthened with a properly developed data‐based time and work analysis. A staffing grid is presented, along with a development methodology that facilitated our justification. Though our grid is for a large academic facility, the methodology can be extended to a non‐academic setting, and to a smaller scale. This grid method not only equates the clinical needs with the quantity of staffing, but can also help generate the personnel budget, based on the type of staff and personnel required. The grid is easily adaptable when changes to the clinical environment change, such as an increase in IMRT or IGRT applications. PACS number: 87.55.tm, 87.55.Qr
- 31 October 2009
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 93 (1) , 64-70
Dosimetric consequences of uncorrected setup errors in helical Tomotherapy treatments of breast-cancer patients
- 31 October 2009
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 93 (1) , 64-70
Dosimetric consequences of uncorrected setup errors in helical Tomotherapy treatments of breast-cancer patients
- Top Cited Papers
- 17 August 2009
- Published by Wiley in Medical Physics
- Vol. 36 (9Part1) , 4197-4212
Task Group 142 report: Quality assurance of medical acceleratorsa)
The task group (TG) for quality assurance of medical accelerators was constituted by the American Association of Physicists in Medicine's Science Council under the direction of the Radiation Therapy Committee and the Quality Assurance and Outcome Improvement Subcommittee. The task group (TG‐142) had two main charges. First to update, as needed, recommendations of Table II of the AAPM TG‐40 report on quality assurance and second, to add recommendations for asymmetric jaws, multileaf collimation (MLC), and dynamic/virtual wedges. The TG accomplished the update to TG‐40, specifying new test and tolerances, and has added recommendations for not only the new ancillary delivery technologies but also for imaging devices that are part of the linear accelerator. The imaging devices include x‐ray imaging, photon portal imaging, and cone‐beam CT. The TG report was designed to account for the types of treatments delivered with the particular machine. For example, machines that are used for radiosurgery treatments or intensity‐modulated radiotherapy(IMRT) require different tests and/or tolerances. There are specific recommendations for MLC quality assurance for machines performing IMRT. The report also gives recommendations as to action levels for the physicists to implement particular actions, whether they are inspection, scheduled action, or immediate and corrective action. The report is geared to be flexible for the physicist to customize the QA program depending on clinical utility. There are specific tables according to daily, monthly, and annual reviews, along with unique tables for wedge systems, MLC, and imaging checks. The report also gives specific recommendations regarding setup of a QA program by the physicist in regards to building a QA team, establishing procedures, training of personnel, documentation, and end‐to‐end system checks. The tabulated items of this report have been considerably expanded as compared with the original TG‐40 report and the recommended tolerances accommodate differences in the intended use of the machine functionality (non‐IMRT, IMRT, and stereotactic delivery).
- 17 August 2009
- Published by Wiley in Medical Physics
- Vol. 36 (9Part1) , 4197-4212
Top Cited PapersTask Group 142 report: Quality assurance of medical acceleratorsa)
The task group (TG) for quality assurance of medical accelerators was constituted by the American Association of Physicists in Medicine's Science Council under the direction of the Radiation Therapy Committee and the Quality Assurance and Outcome Improvement Subcommittee. The task group (TG‐142) had two main charges. First to update, as needed, recommendations of Table II of the AAPM TG‐40 report on quality assurance and second, to add recommendations for asymmetric jaws, multileaf collimation (MLC), and dynamic/virtual wedges. The TG accomplished the update to TG‐40, specifying new test and tolerances, and has added recommendations for not only the new ancillary delivery technologies but also for imaging devices that are part of the linear accelerator. The imaging devices include x‐ray imaging, photon portal imaging, and cone‐beam CT. The TG report was designed to account for the types of treatments delivered with the particular machine. For example, machines that are used for radiosurgery treatments or intensity‐modulated radiotherapy(IMRT) require different tests and/or tolerances. There are specific recommendations for MLC quality assurance for machines performing IMRT. The report also gives recommendations as to action levels for the physicists to implement particular actions, whether they are inspection, scheduled action, or immediate and corrective action. The report is geared to be flexible for the physicist to customize the QA program depending on clinical utility. There are specific tables according to daily, monthly, and annual reviews, along with unique tables for wedge systems, MLC, and imaging checks. The report also gives specific recommendations regarding setup of a QA program by the physicist in regards to building a QA team, establishing procedures, training of personnel, documentation, and end‐to‐end system checks. The tabulated items of this report have been considerably expanded as compared with the original TG‐40 report and the recommended tolerances accommodate differences in the intended use of the machine functionality (non‐IMRT, IMRT, and stereotactic delivery).
- 19 December 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (2) , 327-339
Delivery of modulated electron beams with conventional photon multi-leaf collimators
Electron beam radiotherapy is an accepted method to treat shallow tumors. However, modulation of electrons to customize dose distributions has not readily been achieved. Studies of bolus and tertiary collimation systems have been met with limitations. We pursue the use of photon multi-leaf collimators (MLC) for modulated electron radiotherapy (MERT) to achieve customized distributions for potential clinical use. As commercial planning systems do not support the use of MLC with electrons, planning was conducted using Monte Carlo calculations. Segmented and dynamic modulated delivery of multiple electron segments was configured, calculated and delivered for validation. Delivery of electrons with segmented or dynamic leaf motion was conducted. A phantom possessing an idealized stepped target was planned and optimized with subsequent validation by measurements. Finally, clinical treatment plans were conducted for post-mastectomy and cutaneous lymphoma of the scalp using forward optimization techniques. Comparison of calculations and measurements was successful with agreement of +/-2%/2 mm for the energies, segment sizes, depths tested for delivered segments for the dynamic and segmented delivery. Clinical treatment plans performed provided optimal dose coverage of the target while sparing distal organs at risk. Execution of plans using an anthropomorphic phantom to ensure safe and efficient delivery was conducted. Our study validates that MERT is not only possible using the photon MLC, but the efficient and safe delivery inherent with the dynamic delivery provides an ideal technique for shallow tumor treatment.
- 19 December 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (2) , 327-339
Delivery of modulated electron beams with conventional photon multi-leaf collimators
Electron beam radiotherapy is an accepted method to treat shallow tumors. However, modulation of electrons to customize dose distributions has not readily been achieved. Studies of bolus and tertiary collimation systems have been met with limitations. We pursue the use of photon multi-leaf collimators (MLC) for modulated electron radiotherapy (MERT) to achieve customized distributions for potential clinical use. As commercial planning systems do not support the use of MLC with electrons, planning was conducted using Monte Carlo calculations. Segmented and dynamic modulated delivery of multiple electron segments was configured, calculated and delivered for validation. Delivery of electrons with segmented or dynamic leaf motion was conducted. A phantom possessing an idealized stepped target was planned and optimized with subsequent validation by measurements. Finally, clinical treatment plans were conducted for post-mastectomy and cutaneous lymphoma of the scalp using forward optimization techniques. Comparison of calculations and measurements was successful with agreement of +/-2%/2 mm for the energies, segment sizes, depths tested for delivered segments for the dynamic and segmented delivery. Clinical treatment plans performed provided optimal dose coverage of the target while sparing distal organs at risk. Execution of plans using an anthropomorphic phantom to ensure safe and efficient delivery was conducted. Our study validates that MERT is not only possible using the photon MLC, but the efficient and safe delivery inherent with the dynamic delivery provides an ideal technique for shallow tumor treatment.
- 1 August 2008
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 71 (5) , 1511-1517
Estimation of Setup Uncertainty Using Planar and MVCT Imaging for Gynecologic Malignancies
- 1 August 2008
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 71 (5) , 1511-1517
Estimation of Setup Uncertainty Using Planar and MVCT Imaging for Gynecologic Malignancies
- 1 August 2007
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 68 (5) , 1276-1288
ASTRO’s 2007 Core Physics Curriculum for Radiation Oncology Residents
- 1 August 2007
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 68 (5) , 1276-1288
ASTRO’s 2007 Core Physics Curriculum for Radiation Oncology Residents
- 22 June 2006
- Published by Wiley in Medical Physics
- Vol. 33 (7Part1) , 2525-2531
Peripheral doses from pediatric IMRT
Peripheral dose (PD) data exist for conventional fields and intensity‐modulated radiotherapy (IMRT) delivery to standard adult‐sized phantoms. Pediatric peripheral dose reports are limited to conventional therapy and are model based. Our goal was to ascertain whether data acquired from full phantom studies and/or pediatric models, with IMRT treatment times, could predict Organ at Risk (OAR) dose for pediatric IMRT. As monitor units (MUs) are greater for IMRT, it is expected IMRT PD will be higher; potentially compounded by decreased patient size (absorption). Baseline slab phantom peripheral dose measurements were conducted for very small field sizes (from ). Data were collected at distances ranging from away from the field edges. Collimation was either with the collimating jaws or the multileaf collimator (MLC) oriented either perpendicular or along the peripheral dose measurement plane. For the clinical tests, five patients with intracranial or base of skull lesions were chosen. IMRT and conventional three‐dimensional (3D) plans for the same patient/target/dose , were optimized without limitation to the number of fields or wedge use. Six MV, 120‐leaf MLC Varian axial beams were used. A phantom mimicking a ‐old was configured per Center for Disease Control data. Micro and cylindrical ionization chambers were appropriated for the thyroid, breast, ovaries, and testes. The PD was recorded by electrometers set to the scale. Each system set was uniquely calibrated. For the slab phantom studies, close peripheral points were found to have a higher dose for low energy and larger field size and when MLC was not deployed. For points more distant from the field edge, the PD was higher for high‐energy beams. MLC orientation was found to be inconsequential for the small fields tested. The thyroid dose was lower for IMRT delivery than that predicted for conventional (ratio of IMRT/cnventional ranged from 0.47–0.94) doses , respectively. Prior phantom reports are for fields or greater, while pediatric central nervous system fields range from , and effectively much smaller for IMRT . Peripheral dose in close proximity ( from the field edge) is dominated by internal scatter; therefore, field‐size differences overwhelm phantom size affects and increased MU. Distant peripheral dose, dominated by head leakage, was higher than predicted, even when accounting for MUs ( of 3) likely due to the pediatric phantom size. The ratio of the testes dose ranged from 3.3–5.3 for IMRT/conventional. PD to OAR for pediatric IMRT cannot be predicted from large‐field full phantom studies. For regional OAR, doses are likely lower than predicted by existing “large field” data, while the distant PD is higher.
- 22 June 2006
- Published by Wiley in Medical Physics
- Vol. 33 (7Part1) , 2525-2531
Peripheral doses from pediatric IMRT
Peripheral dose (PD) data exist for conventional fields and intensity‐modulated radiotherapy (IMRT) delivery to standard adult‐sized phantoms. Pediatric peripheral dose reports are limited to conventional therapy and are model based. Our goal was to ascertain whether data acquired from full phantom studies and/or pediatric models, with IMRT treatment times, could predict Organ at Risk (OAR) dose for pediatric IMRT. As monitor units (MUs) are greater for IMRT, it is expected IMRT PD will be higher; potentially compounded by decreased patient size (absorption). Baseline slab phantom peripheral dose measurements were conducted for very small field sizes (from ). Data were collected at distances ranging from away from the field edges. Collimation was either with the collimating jaws or the multileaf collimator (MLC) oriented either perpendicular or along the peripheral dose measurement plane. For the clinical tests, five patients with intracranial or base of skull lesions were chosen. IMRT and conventional three‐dimensional (3D) plans for the same patient/target/dose , were optimized without limitation to the number of fields or wedge use. Six MV, 120‐leaf MLC Varian axial beams were used. A phantom mimicking a ‐old was configured per Center for Disease Control data. Micro and cylindrical ionization chambers were appropriated for the thyroid, breast, ovaries, and testes. The PD was recorded by electrometers set to the scale. Each system set was uniquely calibrated. For the slab phantom studies, close peripheral points were found to have a higher dose for low energy and larger field size and when MLC was not deployed. For points more distant from the field edge, the PD was higher for high‐energy beams. MLC orientation was found to be inconsequential for the small fields tested. The thyroid dose was lower for IMRT delivery than that predicted for conventional (ratio of IMRT/cnventional ranged from 0.47–0.94) doses , respectively. Prior phantom reports are for fields or greater, while pediatric central nervous system fields range from , and effectively much smaller for IMRT . Peripheral dose in close proximity ( from the field edge) is dominated by internal scatter; therefore, field‐size differences overwhelm phantom size affects and increased MU. Distant peripheral dose, dominated by head leakage, was higher than predicted, even when accounting for MUs ( of 3) likely due to the pediatric phantom size. The ratio of the testes dose ranged from 3.3–5.3 for IMRT/conventional. PD to OAR for pediatric IMRT cannot be predicted from large‐field full phantom studies. For regional OAR, doses are likely lower than predicted by existing “large field” data, while the distant PD is higher.