Bruno Frackowiak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bruno Frackowiak has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Cameron Tropea
Technical University of Darmstadt
3 shared publications Alain Strzelecki
ONERA, DMAE, 2 Avenue Edouard Belin, 31055 Toulouse, France
2 shared publicationsGérard Lavergne
ONERA, DMAE, 2 Avenue Edouard Belin, 31055 Toulouse, France
2 shared publications
Latest Publications
- 26 April 2010
- Published by Optica Publishing Group in Optics Letters
- Vol. 35 (9) , 1386-1388
Fluorescence modeling of droplets intersecting a focused laser beam
Laser-induced fluorescence (LIF) has been previously used in various forms to characterize droplets in a spray, according to either size or temperature. A rigorous examination is presented of the LIF signal obtained when a water droplet seeded by Rhodamine 6G passes through one or two highly focused laser beams, i.e., with a beam waist of the order of the droplet diameter or smaller. The calculations are performed with a fluorescence model based on the generalized Lorenz–Mie theory and on ray tracing methods, assuming that the droplet is spherical and nonabsorbing. A parametric study reveals a size dependent signal as the droplet passes through the focused beam(s). The observed signal features suggest several avenues for the use of LIF scattering for size and velocity measurements of individual droplets.
- 26 April 2010
- Published by Optica Publishing Group in Optics Letters
- Vol. 35 (9) , 1386-1388
Fluorescence modeling of droplets intersecting a focused laser beam
Laser-induced fluorescence (LIF) has been previously used in various forms to characterize droplets in a spray, according to either size or temperature. A rigorous examination is presented of the LIF signal obtained when a water droplet seeded by Rhodamine 6G passes through one or two highly focused laser beams, i.e., with a beam waist of the order of the droplet diameter or smaller. The calculations are performed with a fluorescence model based on the generalized Lorenz–Mie theory and on ray tracing methods, assuming that the droplet is spherical and nonabsorbing. A parametric study reveals a size dependent signal as the droplet passes through the focused beam(s). The observed signal features suggest several avenues for the use of LIF scattering for size and velocity measurements of individual droplets.
- 14 April 2010
- Published by Optica Publishing Group in Applied Optics
- Vol. 49 (12) , 2363-2370
Numerical analysis of diameter influence on droplet fluorescence
Laser-induced fluorescence (LIF) is used in planar droplet sizing, assuming that the signal integrated over the droplet is proportional to its volume. Nevertheless, this assumption is rigorously valid in nonabsorbing mixtures. We performed an examination of the LIF signal with a fluorescence model, based on the Lorenz–Mie theory and on ray-tracing methods, for n-heptane droplets seeded by 3-pentanone. A parametrical study quantifies the bias caused not only by the absorption of the laser, but also by shadow zones in the droplets, which do not contribute to the fluorescence signal. Moreover, the effect of the first- and higher-order internal reflections is examined. The results of this study have immediately implications for the design of measurement techniques.
- 14 April 2010
- Published by Optica Publishing Group in Applied Optics
- Vol. 49 (12) , 2363-2370
Numerical analysis of diameter influence on droplet fluorescence
Laser-induced fluorescence (LIF) is used in planar droplet sizing, assuming that the signal integrated over the droplet is proportional to its volume. Nevertheless, this assumption is rigorously valid in nonabsorbing mixtures. We performed an examination of the LIF signal with a fluorescence model, based on the Lorenz–Mie theory and on ray-tracing methods, for n-heptane droplets seeded by 3-pentanone. A parametrical study quantifies the bias caused not only by the absorption of the laser, but also by shadow zones in the droplets, which do not contribute to the fluorescence signal. Moreover, the effect of the first- and higher-order internal reflections is examined. The results of this study have immediately implications for the design of measurement techniques.
- 31 March 2010
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 53 (7-8) , 1392-1401
Numerical analysis of the interactions between evaporating droplets in a monodisperse stream
- 31 March 2010
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 53 (7-8) , 1392-1401
Numerical analysis of the interactions between evaporating droplets in a monodisperse stream
- 26 November 2008
- Published by Springer Nature in Experiments in Fluids
- Vol. 46 (4) , 671-682
A liquid–vapor interface positioning method applied to PLIF measurements around evaporating monodisperse droplet streams
- 26 November 2008
- Published by Springer Nature in Experiments in Fluids
- Vol. 46 (4) , 671-682
A liquid–vapor interface positioning method applied to PLIF measurements around evaporating monodisperse droplet streams