Rodney D. Wiersma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Rodney D. Wiersma has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Xinmin Liu
Department of Radiation Oncology, University of California, Los Angeles, California
11 shared publicationsAndrew H. Belcher
Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL, 60637-1470, USA
7 shared publicationsZachary Grelewicz
Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL, 60637-1470, USA
6 shared publicationsAlexander L. Van Slyke
Department of Radiation Oncology, University of Pennsylvania, Philadelphia
2 shared publicationsCameron J. Koch
University of Pennsylvania
2 shared publicationsErik Pearson
Department of Radiation and Cellular Oncology University of Chicago Chicago IL
2 shared publications
Latest Publications
- Open Access
Decreased Damage for proton FLASH vs Conventional Dose Rates in Mouse Jejunum Shown by Quantitative Assessment of γ-H2AX
Purpose: FLASH radiation with ultra-high dose rate delivery is less damaging to normal tissue than conventional radiation ( <1 Gy/s). Since radiation depletes oxygen (ROD), this damage reduction might occur via the oxygen effect. ROD experiments have shown an oxygen-independent reduction in dose effectiveness at FLASH dose rates. However, prior in vivo ROD measurements relied on extracellular oxygen probes that could not penetrate cell membranes, leaving intracellular effects unresolved. To investigate the ROD hypothesis more directly, we developed a novel three-component immunohistochemical assay with algorithmic image processing to quantitatively compare DNA damage following FLASH and conventional irradiation in mouse jejunum. Methods: Mice received intravenous EF5 2 hours before proton irradiation at FLASH (103.63 +/- 17.2 Gy/s) or conventional (0.73 +/- 0.1 Gy/s) dose rates of 2.5 Gy or 5 Gy, with unirradiated controls. Mice were euthanized 30 minutes post-irradiation, and 10 cm of jejunum was frozen as a ‘Swiss Roll’, sectioned, stained, and imaged. Tissue sections were stained for γ-H2AX, DRAQ5, and EF5 to assess DNA double-strand breaks, total DNA content, and hypoxia, respectively. An in-house algorithm identified individual cell nuclei and registered each nucleus with its corresponding γ-H2AX and EF5 signals, enabling quantitative measurement of DNA damage as a function of local tissue hypoxia. Results: Hypoxia was greatest in the villi and, to a lesser extent, the outer jejunal musculature, with substantial inter-animal variation. DNA damage decreased in hypoxic regions. FLASH enhanced the hypoxia-associated reduction in DNA damage compared with conventional dose rate and, separately, revealed an oxygen-independent reduction in DNA damage, suggesting an additional FLASH sparing mechanism. Conclusion: Current results suggest that FLASH compared to conventional dose rate radiation caused less DNA damage with increasing effect at low oxygen levels, a result consistent with ROD as a mechanism. Pronounced tissue heterogeneity in murine jejunum requires further studies to segment the effect for each tissue type.
Open AccessDecreased Damage for proton FLASH vs Conventional Dose Rates in Mouse Jejunum Shown by Quantitative Assessment of γ-H2AX
Purpose: FLASH radiation with ultra-high dose rate delivery is less damaging to normal tissue than conventional radiation ( <1 Gy/s). Since radiation depletes oxygen (ROD), this damage reduction might occur via the oxygen effect. ROD experiments have shown an oxygen-independent reduction in dose effectiveness at FLASH dose rates. However, prior in vivo ROD measurements relied on extracellular oxygen probes that could not penetrate cell membranes, leaving intracellular effects unresolved. To investigate the ROD hypothesis more directly, we developed a novel three-component immunohistochemical assay with algorithmic image processing to quantitatively compare DNA damage following FLASH and conventional irradiation in mouse jejunum. Methods: Mice received intravenous EF5 2 hours before proton irradiation at FLASH (103.63 +/- 17.2 Gy/s) or conventional (0.73 +/- 0.1 Gy/s) dose rates of 2.5 Gy or 5 Gy, with unirradiated controls. Mice were euthanized 30 minutes post-irradiation, and 10 cm of jejunum was frozen as a ‘Swiss Roll’, sectioned, stained, and imaged. Tissue sections were stained for γ-H2AX, DRAQ5, and EF5 to assess DNA double-strand breaks, total DNA content, and hypoxia, respectively. An in-house algorithm identified individual cell nuclei and registered each nucleus with its corresponding γ-H2AX and EF5 signals, enabling quantitative measurement of DNA damage as a function of local tissue hypoxia. Results: Hypoxia was greatest in the villi and, to a lesser extent, the outer jejunal musculature, with substantial inter-animal variation. DNA damage decreased in hypoxic regions. FLASH enhanced the hypoxia-associated reduction in DNA damage compared with conventional dose rate and, separately, revealed an oxygen-independent reduction in DNA damage, suggesting an additional FLASH sparing mechanism. Conclusion: Current results suggest that FLASH compared to conventional dose rate radiation caused less DNA damage with increasing effect at low oxygen levels, a result consistent with ROD as a mechanism. Pronounced tissue heterogeneity in murine jejunum requires further studies to segment the effect for each tissue type.
- Open Access
- 24 September 2025
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 125 (2) , 620-629
Performance of a Novel Frameless and Maskless Robotic Head Motion Compensation System for Stereotactic Radiosurgery in a Realistic Clinical Environment with Healthy Volunteers
- 24 September 2025
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 125 (2) , 620-629
Open AccessPerformance of a Novel Frameless and Maskless Robotic Head Motion Compensation System for Stereotactic Radiosurgery in a Realistic Clinical Environment with Healthy Volunteers
- Open Access
- 19 August 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (17) , 175002
Physicochemical indication of the FLASH effect from shoot-through proton pencil beam scanning parameters delivered under ultra-high dose rates
Objective. Ultra-high dose rate (UHDR) proton pencil beam scanning (PBS) delivery results in irregular temporal-varying dose accumulation. It is difficult to establish a dose rate standard for the indication of proton PBS FLASH effect. In this work, we adopted a published physicochemical approach and investigated the impact of proton PBS UHDR parameters on the formation and downstream reactions of reactive oxygen species (ROS). Approach. From the ROS physicochemical model, the dose-rate dependent alkyl hydroperoxide (ROOH) formation was validated against published lipid peroxide absorbance data and correlated with mice skin damage data. For proton PBS delivery with specified beam current, voxelized temporal dose and ROS accumulation was calculated at the plateau region to simulate a shoot-through FLASH delivery. The ROS were obtained mimicking the irradiation of hypoxic skin. We examine the ROS-volume histogram in relation to the proton PBS delivery parameters. Main results. ROOH production clearly indicates sparing effects under UHDR. For PBS deliveries of 10 Gy to a 100 × 100 mm2 field at 8 mm depth, the ROOH yield at 500 nA FLASH beam current is equivalent to a 8.78 Gy delivery at 1nA CONV delivery. The yield of ROOH depends strongly on the dose and beam current but has minimal dependency on the field size and spot spacing. Introducing inter-beam intervals of two minutes reduces the FLASH reduction in ROOH, consistent with reduced FLASH effect in murine experiment. Significance. The volumetric statistics of the ROOH yield showed consistent indication of FLASH effects in preclinical observations and correlated with the lipid peroxidation damage in tissue. Using simulated ROOH production metrics can potentially indicate the FLASH sparing effect under various PBS delivery parameters. Our simulations indicate that the shoot-through PBS FLASH effect depends mainly on the total dose and the pencil beam current, and is relatively independent of field sizes and spot spacings.
- 19 August 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (17) , 175002
Open AccessPhysicochemical indication of the FLASH effect from shoot-through proton pencil beam scanning parameters delivered under ultra-high dose rates
Objective. Ultra-high dose rate (UHDR) proton pencil beam scanning (PBS) delivery results in irregular temporal-varying dose accumulation. It is difficult to establish a dose rate standard for the indication of proton PBS FLASH effect. In this work, we adopted a published physicochemical approach and investigated the impact of proton PBS UHDR parameters on the formation and downstream reactions of reactive oxygen species (ROS). Approach. From the ROS physicochemical model, the dose-rate dependent alkyl hydroperoxide (ROOH) formation was validated against published lipid peroxide absorbance data and correlated with mice skin damage data. For proton PBS delivery with specified beam current, voxelized temporal dose and ROS accumulation was calculated at the plateau region to simulate a shoot-through FLASH delivery. The ROS were obtained mimicking the irradiation of hypoxic skin. We examine the ROS-volume histogram in relation to the proton PBS delivery parameters. Main results. ROOH production clearly indicates sparing effects under UHDR. For PBS deliveries of 10 Gy to a 100 × 100 mm2 field at 8 mm depth, the ROOH yield at 500 nA FLASH beam current is equivalent to a 8.78 Gy delivery at 1nA CONV delivery. The yield of ROOH depends strongly on the dose and beam current but has minimal dependency on the field size and spot spacing. Introducing inter-beam intervals of two minutes reduces the FLASH reduction in ROOH, consistent with reduced FLASH effect in murine experiment. Significance. The volumetric statistics of the ROOH yield showed consistent indication of FLASH effects in preclinical observations and correlated with the lipid peroxidation damage in tissue. Using simulated ROOH production metrics can potentially indicate the FLASH sparing effect under various PBS delivery parameters. Our simulations indicate that the shoot-through PBS FLASH effect depends mainly on the total dose and the pencil beam current, and is relatively independent of field sizes and spot spacings.
- Open Access
- 13 July 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (7) , e70138
A novel SGRT system for real‐time optical surface tracking or guidance
Purpose: Optical 3D surface imaging is a technique that reconstructs a patient's surface without requiring external markers. This study aimed to evaluate the static and dynamic accuracy, as well as performance under varying conditions, including changes in skin surface color, ambient room lighting, and the size of the tracked region of interest (ROI), for a novel surface guided radiation therapy (SGRT) system (LUNA 3D). Methods: The LUNA 3D consisted of three ceiling mounted camera pods, with each pod equipped with a pattern projector and two camera units. Blue 465 nm light projection, combined with narrow bandpass filters and advanced triggering, were used to improve tracking accuracy to surface color and ambient room light variations. GPU processing enabled surface acquisition at high speeds. To investigate static and dynamic accuracy, a 6‐degree‐of‐freedom (6DoF) robot stage was used to move head phantoms to known positions in 6D space. A 6D infrared (IR) tracking camera was employed as a secondary verification tool. Results: When tracking a static head phantom with a clinically relevant ROI, the LUNA 3D demonstrated a translational noise root‐mean‐sqaured‐error (RMSE) of approximately 0.04 mm LAT, 0.06 mm LNG, and 0.04 mm VRT and a rotational noise RMSE of 0.04 pitch, 0.04 roll, and 0.04 yaw. For varying surface colors, ambient light conditions, and ROI sizes, LUNA 3D's performance, when compared to the IR camera, exhibited a maximum difference of 0.14 mm. The measured frame rate remained approximately constant at 12.5 fps for all ROI sizes tested. Conclusion: The LUNA 3D demonstrated high sub‐millimeter and sub‐degree tracking accuracy, comparable to or better than that of an IR tracking camera, while exhibiting minimal sensitivity to surface color and ambient lighting conditions. Additionally, it maintained stable and consistent frame rate tracking regardless of the tracked ROI size.
- 13 July 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (7) , e70138
Open AccessA novel SGRT system for real‐time optical surface tracking or guidance
Purpose: Optical 3D surface imaging is a technique that reconstructs a patient's surface without requiring external markers. This study aimed to evaluate the static and dynamic accuracy, as well as performance under varying conditions, including changes in skin surface color, ambient room lighting, and the size of the tracked region of interest (ROI), for a novel surface guided radiation therapy (SGRT) system (LUNA 3D). Methods: The LUNA 3D consisted of three ceiling mounted camera pods, with each pod equipped with a pattern projector and two camera units. Blue 465 nm light projection, combined with narrow bandpass filters and advanced triggering, were used to improve tracking accuracy to surface color and ambient room light variations. GPU processing enabled surface acquisition at high speeds. To investigate static and dynamic accuracy, a 6‐degree‐of‐freedom (6DoF) robot stage was used to move head phantoms to known positions in 6D space. A 6D infrared (IR) tracking camera was employed as a secondary verification tool. Results: When tracking a static head phantom with a clinically relevant ROI, the LUNA 3D demonstrated a translational noise root‐mean‐sqaured‐error (RMSE) of approximately 0.04 mm LAT, 0.06 mm LNG, and 0.04 mm VRT and a rotational noise RMSE of 0.04 pitch, 0.04 roll, and 0.04 yaw. For varying surface colors, ambient light conditions, and ROI sizes, LUNA 3D's performance, when compared to the IR camera, exhibited a maximum difference of 0.14 mm. The measured frame rate remained approximately constant at 12.5 fps for all ROI sizes tested. Conclusion: The LUNA 3D demonstrated high sub‐millimeter and sub‐degree tracking accuracy, comparable to or better than that of an IR tracking camera, while exhibiting minimal sensitivity to surface color and ambient lighting conditions. Additionally, it maintained stable and consistent frame rate tracking regardless of the tracked ROI size.
- 14 July 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (14) , 145020
An AI-based universal phantom analysis method based on XML-SVG wireframes with novel functional object identifiers
Objective. Quality assurance (QA) testing must be performed at regular intervals to ensure that medical devices are operating within designed specifications. Numerous QA phantoms and software packages have been developed to facilitate measurements of machine performance. However, due to the hard-coded nature of geometric phantom definition in analysis software, users are typically limited to the use of a small subset of compatible QA phantoms. In this work, we present a novel AI-based universal Phantom (UniPhan) algorithm that is not phantom specific and can be easily adapted to any pre-existing image-based QA phantom. Approach. Extensible Markup Language Scalable Vector Graphics (XML-SVG) was modified to include several new tags describing the function of embedded phantom objects for use in QA analysis. Functional tags include contrast and density plugs, spatial linearity markers, resolution bars and edges, uniformity regions, and light-radiation field coincidence areas. Machine learning was used to develop an image classification model for automatic phantom type detection. After AI phantom identification, UniPhan imported the corresponding XML-SVG wireframe, registered it to the image taken during the QA process, performed analysis on the functional tags, and exported results for comparison to expected device specifications. Analysis results were compared to those generated by manual image analysis. Main results. XML-SVG wireframes were generated for several commercial phantoms including ones specific to CT, CBCT, kV planar imaging, and MV imaging. Several functional objects were developed and assigned to the graphical elements of the phantoms. The AI classification model was tested for training and validation accuracy and loss, along with phantom type prediction accuracy and speed. The results reported training and validation accuracies of 99%, phantom type prediction confidence scores of around 100%, and prediction speeds of around 0.1 s. Compared to manual image analysis, Uniphan results were consistent across all metrics including contrast-to-noise ratio, modulation-transfer function, HU accuracy, and uniformity. Significance. The UniPhan method can identify phantom type and use its corresponding wireframe to perform QA analysis. As these wireframes can be generated in a variety of ways this represents an accessible automated method of analyzing image-based QA phantoms that is flexible in scope and implementation.
- 14 July 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (14) , 145020
An AI-based universal phantom analysis method based on XML-SVG wireframes with novel functional object identifiers
Objective. Quality assurance (QA) testing must be performed at regular intervals to ensure that medical devices are operating within designed specifications. Numerous QA phantoms and software packages have been developed to facilitate measurements of machine performance. However, due to the hard-coded nature of geometric phantom definition in analysis software, users are typically limited to the use of a small subset of compatible QA phantoms. In this work, we present a novel AI-based universal Phantom (UniPhan) algorithm that is not phantom specific and can be easily adapted to any pre-existing image-based QA phantom. Approach. Extensible Markup Language Scalable Vector Graphics (XML-SVG) was modified to include several new tags describing the function of embedded phantom objects for use in QA analysis. Functional tags include contrast and density plugs, spatial linearity markers, resolution bars and edges, uniformity regions, and light-radiation field coincidence areas. Machine learning was used to develop an image classification model for automatic phantom type detection. After AI phantom identification, UniPhan imported the corresponding XML-SVG wireframe, registered it to the image taken during the QA process, performed analysis on the functional tags, and exported results for comparison to expected device specifications. Analysis results were compared to those generated by manual image analysis. Main results. XML-SVG wireframes were generated for several commercial phantoms including ones specific to CT, CBCT, kV planar imaging, and MV imaging. Several functional objects were developed and assigned to the graphical elements of the phantoms. The AI classification model was tested for training and validation accuracy and loss, along with phantom type prediction accuracy and speed. The results reported training and validation accuracies of 99%, phantom type prediction confidence scores of around 100%, and prediction speeds of around 0.1 s. Compared to manual image analysis, Uniphan results were consistent across all metrics including contrast-to-noise ratio, modulation-transfer function, HU accuracy, and uniformity. Significance. The UniPhan method can identify phantom type and use its corresponding wireframe to perform QA analysis. As these wireframes can be generated in a variety of ways this represents an accessible automated method of analyzing image-based QA phantoms that is flexible in scope and implementation.
- 31 May 2022
- Published by Radiation Research Society in Radiation Research
- Vol. 198 (2) , 181-189
Oxygen Monitoring in Model Solutions and In Vivo in Mice During Proton Irradiation at Conventional and FLASH Dose Rates
FLASH is a high-dose-rate form of radiation therapy that has the reported ability, compared with conventional dose rates, to spare normal tissues while being equipotent in tumor control, thereby increasing the therapeutic ratio. The mechanism underlying this normal tissue sparing effect is currently unknown, however one possibility is radiochemical oxygen depletion (ROD) during dose delivery in tissue at FLASH dose rates. In order to investigate this possibility, we used the phosphorescence quenching method to measure oxygen partial pressure before, during and after proton radiation delivery in model solutions and in normal muscle and sarcoma tumors in mice, at both conventional (Conv) (∼0.5 Gy/s) and FLASH (∼100 Gy/s) dose rates. Radiation dosimetry was determined by Advanced Markus Chamber and EBT-XL film. For solutions contained in sealed glass vials, phosphorescent probe Oxyphor PtG4 (1 µM) was dissolved in a buffer (10 mM HEPES) containing glycerol (1 M), glucose (5 mM) and glutathione (5 mM), designed to mimic the reducing and free radical-scavenging nature of the intracellular environment. In vivo oxygen measurements were performed 24 h after injection of PtG4 into the interstitial space of either normal thigh muscle or subcutaneous sarcoma tumors in mice. The “g-value” for ROD is reported in mmHg/Gy, which represents a slight modification of the more standard chemical definition (µM/Gy). In solutions, proton irradiation at conventional dose rates resulted in a g-value for ROD of up to 0.55 mmHg/Gy, consistent with earlier studies using X or gamma rays. At FLASH dose rates, the g-value for ROD was ∼25% lower, 0.37 mmHg/Gy. pO2 levels were stable after each dose delivery. For normal muscle in vivo, oxygen depletion during irradiation was counterbalanced by resupply from the vasculature. This process was fast enough to maintain tissue pO2 virtually unchanged at Conv dose rates. However, during FLASH irradiation there was a stepwise decrease in pO2 (g-value ∼0.28 mmHg/Gy), followed by a rebound to the initial level after ∼8 s. The g-values were smaller and recovery times longer in tumor tissue when compared to muscle and may be related to the lower initial endogenous pO2 levels in the former. Considering that the FLASH effect is seen in vivo even at doses as low as 10 Gy, it is difficult to reconcile the amount of protection seen by oxygen depletion alone. However, the phosphorescence probe in our experiments was confined to the extracellular space, and it remains possible that intracellular oxygen depletion was greater than observed herein. In cell-mimicking solutions the oxygen depletion g-vales were indeed significantly higher than observed in vivo.
- 31 May 2022
- Published by Radiation Research Society in Radiation Research
- Vol. 198 (2) , 181-189
Oxygen Monitoring in Model Solutions and In Vivo in Mice During Proton Irradiation at Conventional and FLASH Dose Rates
FLASH is a high-dose-rate form of radiation therapy that has the reported ability, compared with conventional dose rates, to spare normal tissues while being equipotent in tumor control, thereby increasing the therapeutic ratio. The mechanism underlying this normal tissue sparing effect is currently unknown, however one possibility is radiochemical oxygen depletion (ROD) during dose delivery in tissue at FLASH dose rates. In order to investigate this possibility, we used the phosphorescence quenching method to measure oxygen partial pressure before, during and after proton radiation delivery in model solutions and in normal muscle and sarcoma tumors in mice, at both conventional (Conv) (∼0.5 Gy/s) and FLASH (∼100 Gy/s) dose rates. Radiation dosimetry was determined by Advanced Markus Chamber and EBT-XL film. For solutions contained in sealed glass vials, phosphorescent probe Oxyphor PtG4 (1 µM) was dissolved in a buffer (10 mM HEPES) containing glycerol (1 M), glucose (5 mM) and glutathione (5 mM), designed to mimic the reducing and free radical-scavenging nature of the intracellular environment. In vivo oxygen measurements were performed 24 h after injection of PtG4 into the interstitial space of either normal thigh muscle or subcutaneous sarcoma tumors in mice. The “g-value” for ROD is reported in mmHg/Gy, which represents a slight modification of the more standard chemical definition (µM/Gy). In solutions, proton irradiation at conventional dose rates resulted in a g-value for ROD of up to 0.55 mmHg/Gy, consistent with earlier studies using X or gamma rays. At FLASH dose rates, the g-value for ROD was ∼25% lower, 0.37 mmHg/Gy. pO2 levels were stable after each dose delivery. For normal muscle in vivo, oxygen depletion during irradiation was counterbalanced by resupply from the vasculature. This process was fast enough to maintain tissue pO2 virtually unchanged at Conv dose rates. However, during FLASH irradiation there was a stepwise decrease in pO2 (g-value ∼0.28 mmHg/Gy), followed by a rebound to the initial level after ∼8 s. The g-values were smaller and recovery times longer in tumor tissue when compared to muscle and may be related to the lower initial endogenous pO2 levels in the former. Considering that the FLASH effect is seen in vivo even at doses as low as 10 Gy, it is difficult to reconcile the amount of protection seen by oxygen depletion alone. However, the phosphorescence probe in our experiments was confined to the extracellular space, and it remains possible that intracellular oxygen depletion was greater than observed herein. In cell-mimicking solutions the oxygen depletion g-vales were indeed significantly higher than observed in vivo.
- Open Access
Improving the efficiency of small animal 3D printed compensator IMRT with beamlet intensity total variation regularization
Purpose: There is growing interest in the use of modern 3D printing technology to implement intensity-modulated radiation therapy (IMRT) on the preclinical scale which is analogous to clinical IMRT. However, current 3D-printed IMRT methods suffer from complex modulation patterns leading to long delivery times, excess filament usage, and inaccurate compensator fabrication. In this work, we have developed a total variation regularization (TVR) approach to address these issues. Methods: TVR-IMRT, a technique designed to minimize the intensity difference between neighboring beamlets, was used to optimize the beamlet intensity map, which was then converted to corresponding compensator thicknesses in copper-doped PLA filament. IMRT and TVR-IMRT plans using five beams were generated to treat a mouse heart while sparing lung tissue. The individual field doses and composite dose were delivered to film and compared to the corresponding planned doses using gamma analysis. Results: TVR-IMRT reduced the total variation of both the beamlet intensities and compensator thicknesses by around 50% when compared to standard 3D printed compensator IMRT. The total mass of compensator material consumed and radiation beam-on time were reduced by 20-30%, while DVHs remained comparable. Gamma analysis passing rate with 3%/0.3mm criterion was 89.07% for IMRT and 95.37% for TVR-IMRT. Conclusion: TVR can be applied to small animal IMRT beamlet intensities in order to produce fluence maps and subsequent 3D-printed compensator patterns with less total variation, simplifying 3D printing and reducing the amount of filament required. The TVR-IMRT plan required less beam-on time while maintaining the dose conformity when compared to a traditional IMRT plan.
Open AccessImproving the efficiency of small animal 3D printed compensator IMRT with beamlet intensity total variation regularization
Purpose: There is growing interest in the use of modern 3D printing technology to implement intensity-modulated radiation therapy (IMRT) on the preclinical scale which is analogous to clinical IMRT. However, current 3D-printed IMRT methods suffer from complex modulation patterns leading to long delivery times, excess filament usage, and inaccurate compensator fabrication. In this work, we have developed a total variation regularization (TVR) approach to address these issues. Methods: TVR-IMRT, a technique designed to minimize the intensity difference between neighboring beamlets, was used to optimize the beamlet intensity map, which was then converted to corresponding compensator thicknesses in copper-doped PLA filament. IMRT and TVR-IMRT plans using five beams were generated to treat a mouse heart while sparing lung tissue. The individual field doses and composite dose were delivered to film and compared to the corresponding planned doses using gamma analysis. Results: TVR-IMRT reduced the total variation of both the beamlet intensities and compensator thicknesses by around 50% when compared to standard 3D printed compensator IMRT. The total mass of compensator material consumed and radiation beam-on time were reduced by 20-30%, while DVHs remained comparable. Gamma analysis passing rate with 3%/0.3mm criterion was 89.07% for IMRT and 95.37% for TVR-IMRT. Conclusion: TVR can be applied to small animal IMRT beamlet intensities in order to produce fluence maps and subsequent 3D-printed compensator patterns with less total variation, simplifying 3D printing and reducing the amount of filament required. The TVR-IMRT plan required less beam-on time while maintaining the dose conformity when compared to a traditional IMRT plan.
- 26 June 2021
- Published by Wiley in Medical Physics
- Vol. 48 (11) , E992-E993
The Modern Technology of Radiation Oncology:A Compendium for Medical Physicists and Radiation Oncologists, Volume 4. JacobVan Dyk, editor. Madison, Wisconsin: Medical Physics Publishing, 2020. Hardcover: 522 pp. Price: $175.00. ISBN: 9781951134020.
- 26 June 2021
- Published by Wiley in Medical Physics
- Vol. 48 (11) , E992-E993
The Modern Technology of Radiation Oncology:A Compendium for Medical Physicists and Radiation Oncologists, Volume 4. JacobVan Dyk, editor. Madison, Wisconsin: Medical Physics Publishing, 2020. Hardcover: 522 pp. Price: $175.00. ISBN: 9781951134020.
- Open Access
A conceptual study on real-time adaptive radiation therapy optimization through ultra-fast beamlet control
A central problem in the field of radiation therapy (RT) is how to optimally deliver dose to a patient in a way that fully accounts for anatomical position changes over time. As current RT is a static process, where beam intensities are calculated before the start of treatment, anatomical deviations can result in poor dose conformity. To overcome these limitations, we present a simulation study on a fully dynamic real-time adaptive radiation therapy (RT-ART) optimization approach that uses ultra-fast beamlet control to dynamically adapt to patient motion in real-time. A virtual RT-ART machine was simulated with a rapidly rotating linear accelerator (LINAC) source (60 RPM) and a binary 1D multi-leaf collimator (MLC) operating at 100 Hz. If the real-time tracked target motion exceeded a predefined threshold, a time dependent objective function was solved using fast optimization methods to calculate new beamlet intensities that were then delivered to the patient. To evaluate the approach, system response was analyzed for patient derived continuous drift, step-like, and periodic intra-fractional motion. For each motion type investigated, the RT-ART method was compared against the ideal case with no patient motion (static case) as well as to the case without the use RT-ART. In all cases, isodose lines and dose-volume-histograms (DVH) showed that RT-ART plan quality was approximately the same as the static case, and considerably better than the no RT-ART case. The RT-ART optimization framework has the potential to optimally deliver dose to a patient in a way that fully accounts for anatomical changes due to motion. With continued advances in real-time patient motion tracking and fast computational processes, there is significant potential for the RT-ART optimization process to be realized on next generation RT machines.
Open AccessA conceptual study on real-time adaptive radiation therapy optimization through ultra-fast beamlet control
A central problem in the field of radiation therapy (RT) is how to optimally deliver dose to a patient in a way that fully accounts for anatomical position changes over time. As current RT is a static process, where beam intensities are calculated before the start of treatment, anatomical deviations can result in poor dose conformity. To overcome these limitations, we present a simulation study on a fully dynamic real-time adaptive radiation therapy (RT-ART) optimization approach that uses ultra-fast beamlet control to dynamically adapt to patient motion in real-time. A virtual RT-ART machine was simulated with a rapidly rotating linear accelerator (LINAC) source (60 RPM) and a binary 1D multi-leaf collimator (MLC) operating at 100 Hz. If the real-time tracked target motion exceeded a predefined threshold, a time dependent objective function was solved using fast optimization methods to calculate new beamlet intensities that were then delivered to the patient. To evaluate the approach, system response was analyzed for patient derived continuous drift, step-like, and periodic intra-fractional motion. For each motion type investigated, the RT-ART method was compared against the ideal case with no patient motion (static case) as well as to the case without the use RT-ART. In all cases, isodose lines and dose-volume-histograms (DVH) showed that RT-ART plan quality was approximately the same as the static case, and considerably better than the no RT-ART case. The RT-ART optimization framework has the potential to optimally deliver dose to a patient in a way that fully accounts for anatomical changes due to motion. With continued advances in real-time patient motion tracking and fast computational processes, there is significant potential for the RT-ART optimization process to be realized on next generation RT machines.
- 1 August 2019
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 5 (5) , 055016
A conceptual study on real-time adaptive radiation therapy optimization through ultra-fast beamlet control
A central problem in the field of radiation therapy (RT) is how to optimally deliver dose to a patient in a way that fully accounts for anatomical position changes over time. As current RT is a static process, where beam intensities are calculated before the start of treatment, anatomical deviations can result in poor dose conformity. To overcome these limitations, we present a simulation study on a fully dynamic real-time adaptive radiation therapy (RT-ART) optimization approach that uses ultra-fast beamlet control to dynamically adapt to patient motion in real-time. A virtual RT-ART machine was simulated with a rapidly rotating linear accelerator (LINAC) source (60 RPM) and a binary 1D multi-leaf collimator (MLC) operating at 100 Hz. If the real-time tracked target motion exceeded a predefined threshold, a time dependent objective function was solved using fast optimization methods to calculate new beamlet intensities that were then delivered to the patient. To evaluate the approach, system response was analyzed for patient derived continuous drift, step-like, and periodic intra-fractional motion. For each motion type investigated, the RT-ART method was compared against the ideal case with no patient motion (static case) as well as to the case without the use RT-ART. In all cases, isodose lines and dose-volume-histograms (DVH) showed that RT-ART plan quality was approximately the same as the static case, and considerably better than the no RT-ART case. Based on tests using several different motion types, RT-ART was able to recover dose conformity to the level that it was similar to an ideal RT delivery with no anatomical changes. With continued advances in real-time patient motion tracking and fast computational processes, there is significant potential for the RT-ART optimization process to be realized on next generation RT machines.
- 1 August 2019
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 5 (5) , 055016
A conceptual study on real-time adaptive radiation therapy optimization through ultra-fast beamlet control
A central problem in the field of radiation therapy (RT) is how to optimally deliver dose to a patient in a way that fully accounts for anatomical position changes over time. As current RT is a static process, where beam intensities are calculated before the start of treatment, anatomical deviations can result in poor dose conformity. To overcome these limitations, we present a simulation study on a fully dynamic real-time adaptive radiation therapy (RT-ART) optimization approach that uses ultra-fast beamlet control to dynamically adapt to patient motion in real-time. A virtual RT-ART machine was simulated with a rapidly rotating linear accelerator (LINAC) source (60 RPM) and a binary 1D multi-leaf collimator (MLC) operating at 100 Hz. If the real-time tracked target motion exceeded a predefined threshold, a time dependent objective function was solved using fast optimization methods to calculate new beamlet intensities that were then delivered to the patient. To evaluate the approach, system response was analyzed for patient derived continuous drift, step-like, and periodic intra-fractional motion. For each motion type investigated, the RT-ART method was compared against the ideal case with no patient motion (static case) as well as to the case without the use RT-ART. In all cases, isodose lines and dose-volume-histograms (DVH) showed that RT-ART plan quality was approximately the same as the static case, and considerably better than the no RT-ART case. Based on tests using several different motion types, RT-ART was able to recover dose conformity to the level that it was similar to an ideal RT delivery with no anatomical changes. With continued advances in real-time patient motion tracking and fast computational processes, there is significant potential for the RT-ART optimization process to be realized on next generation RT machines.