Pierre Dubé
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Pierre Dubé has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
A. A. Madej
National Research Council of Canada
3 shared publicationsAlan A. Madej
National Research Council Canada, Ottawa, Ontario, Canada K1A 0R6
3 shared publicationsJ. E. Bernard
National Research Council of Canada
3 shared publicationsL. Marmet
National Research Council of Canada
3 shared publicationsJohn E. Bernard
Frequency and Time Group, Measurement Science and Standards Portfolio, National Research Council of Canada, Ottawa, Canada K1A 0R6
2 shared publicationsA A Madej
National Research Council Canada, Ottawa, Ontario, K1A 0R6, Canada
1 shared publication
Latest Publications
- 5 March 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (3) , 290-298
Absolute frequency measurement of the 88 Sr + clock transition using a GPS link to the SI second
We report the results of a recent measurement of the absolute frequency of the 5 s 2 S 1 / 2 – 4 d 2 D 5 / 2 transition of the 88 S r + ion. The optical frequency was measured against the international atomic time realization of the SI second on the geoid as obtained by frequency transfer using a global positioning system link and the precise point positioning technique. The measurement campaign yielded more than 100 h of frequency data. It was performed with improvements to the stability and accuracy of the single-ion clock compared to the last measurement made in 2012. The single ion clock uncertainty is evaluated at 1.5 × 10 − 17 when contributions from acousto-optic modulator frequency chirps and servo errors are taken into account. The stability of the ion clock is 3 × 10 − 15 at 1 s averaging, a factor of three better than in the previous measurement. The results from the two measurement campaigns are in good agreement. The uncertainty of the measurement, primarily from the link to the SI second, is 0.75 Hz ( 1.7 × 10 − 15 ). The frequency measured for the S – D clock transition of 88 S r + is ν 0 = 444 779 044 095 485.27 ( 75 ) Hz.
- 5 March 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (3) , 290-298
Absolute frequency measurement of the 88 Sr + clock transition using a GPS link to the SI second
We report the results of a recent measurement of the absolute frequency of the 5 s 2 S 1 / 2 – 4 d 2 D 5 / 2 transition of the 88 S r + ion. The optical frequency was measured against the international atomic time realization of the SI second on the geoid as obtained by frequency transfer using a global positioning system link and the precise point positioning technique. The measurement campaign yielded more than 100 h of frequency data. It was performed with improvements to the stability and accuracy of the single-ion clock compared to the last measurement made in 2012. The single ion clock uncertainty is evaluated at 1.5 × 10 − 17 when contributions from acousto-optic modulator frequency chirps and servo errors are taken into account. The stability of the ion clock is 3 × 10 − 15 at 1 s averaging, a factor of three better than in the previous measurement. The results from the two measurement campaigns are in good agreement. The uncertainty of the measurement, primarily from the link to the SI second, is 0.75 Hz ( 1.7 × 10 − 15 ). The frequency measured for the S – D clock transition of 88 S r + is ν 0 = 444 779 044 095 485.27 ( 75 ) Hz.
- Open Access
- 1 June 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 723 (1) , 012018
Sr+single-ion clock
The evaluated uncertainty of the 88Sr+ ion optical clock has decreased by several orders of magnitude during the last 15 years, currently reaching a level of 1.2 x 10-17. In this paper, we review the methods developed to control very effectively the largest frequency shifts that once were the main sources of uncertainty for the 88Sr+ single-ion clock. These shifts are the micromotion shifts, the electric quadrupole shift and the blackbody radiation shift. With further improvements to the evaluation of the systematic shifts, especially the blackbody radiation shift, it is expected that the total uncertainty of the single-ion clock transition frequency will reach the low 10-18 level in the near future.
- 1 June 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 723 (1) , 012018
Open AccessSr+single-ion clock
The evaluated uncertainty of the 88Sr+ ion optical clock has decreased by several orders of magnitude during the last 15 years, currently reaching a level of 1.2 x 10-17. In this paper, we review the methods developed to control very effectively the largest frequency shifts that once were the main sources of uncertainty for the 88Sr+ single-ion clock. These shifts are the micromotion shifts, the electric quadrupole shift and the blackbody radiation shift. With further improvements to the evaluation of the systematic shifts, especially the blackbody radiation shift, it is expected that the total uncertainty of the single-ion clock transition frequency will reach the low 10-18 level in the near future.
- 22 October 2015
- Published by American Physical Society (APS) in Physical Review A
- Vol. 92 (4) , 042119
single-ion optical clock with a stability approaching the quantum projection noise limitA number of optical frequency standards have been evaluated with fractional uncertainties between and . Reduction of the statistical uncertainty of a clock comparison to this level is challenging, requiring the best possible stability to avoid excessively long averaging times. We report recent improvements of our single-ion standard that have reduced its 1-s Allan deviation from to , yielding an order of magnitude decrease in averaging time for a given statistical uncertainty level. Among the improvements made are the implementation of a clear-out laser that transfers the ion from the metastable state to the ground state at each cycle, followed by a state preparation step that transfers the ion to the ground-state magnetic sublevel of the probed transition. With these changes, the ion clock transition interacts with the probe laser at every interrogation cycle. The stability of our optical standard is essentially limited by the quantum projection noise for pulse lengths up to ms.- 22 October 2015
- Published by American Physical Society (APS) in Physical Review A
- Vol. 92 (4) , 042119
single-ion optical clock with a stability approaching the quantum projection noise limitA number of optical frequency standards have been evaluated with fractional uncertainties between and . Reduction of the statistical uncertainty of a clock comparison to this level is challenging, requiring the best possible stability to avoid excessively long averaging times. We report recent improvements of our single-ion standard that have reduced its 1-s Allan deviation from to , yielding an order of magnitude decrease in averaging time for a given statistical uncertainty level. Among the improvements made are the implementation of a clear-out laser that transfers the ion from the metastable state to the ground state at each cycle, followed by a state preparation step that transfers the ion to the ground-state magnetic sublevel of the probed transition. With these changes, the ion clock transition interacts with the probe laser at every interrogation cycle. The stability of our optical standard is essentially limited by the quantum projection noise for pulse lengths up to ms.- 29 April 2014
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 112 (17) , 173002
High-Accuracy Measurement of the Differential Scalar Polarizability of aClock Using the Time-Dilation EffectA new measurement technique allows the uncertainty in the frequency shift of strontium atoms as they decay to be reduced by a factor of 24, paving the way for more accurate atomic clocks.
- 29 April 2014
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 112 (17) , 173002
High-Accuracy Measurement of the Differential Scalar Polarizability of aClock Using the Time-Dilation EffectA new measurement technique allows the uncertainty in the frequency shift of strontium atoms as they decay to be reduced by a factor of 24, paving the way for more accurate atomic clocks.
- 7 February 2013
- Published by American Physical Society (APS) in Physical Review A
- Vol. 87 (2)
Evaluation of systematic shifts of theSrsingle-ion optical frequency standard at thelevelAn ion trap of the end-cap design was built recently at the National Research Council of Canada for improved control of the ${}^{88}$Sr${}^{+}$ single-ion optical frequency standard systematic shifts. The uncertainty on the micromotion-induced shifts is smaller by more than four orders of magnitude when compared to our previous trap system and reaches a fractional frequency uncertainty of $1\ifmmode\times\else\texttimes\fi{}{10}^{$-${}18}$. To obtain this low uncertainty level, the micromotion is minimized with trim electrodes and the trap is operated at a special frequency at which there is anticorrelation between the second-order Doppler and Stark shifts. This choice of operating frequency, determined by the differential scalar polarizability of the clock transition, yields a suppression by a factor of $$\approx${}$28 in the combined micromotion shifts. Like many optical frequency standards, the dominant source of uncertainty in the new trap is the blackbody radiation shift. Its uncertainty has been reduced by an order of magnitude with a recent theoretical evaluation of the differential scalar polarizability of the clock transition. The fractional blackbody shift uncertainty, estimated using a model of the blackbody field at the ion, is $2.2\ifmmode\times\else\texttimes\fi{}{10}^{$-${}17}$. The otherwise dominant electric quadrupole shift is reduced to below the $3\ifmmode\times\else\texttimes\fi{}{10}^{$-${}19}$ level with a cancellation method based on the average frequency of several pairs of Zeeman components. This method also cancels the tensor Stark shift and simplifies the description of the frequency shifts that are quantization-axis dependent. This paper provides a detailed description of the ${}^{88}$Sr${}^{+}$ optical frequency standard uncertainty evaluation and the methods used to make the standard robust against changes in the trap environment. The total fractional frequency uncertainty of the ${}^{88}$Sr${}^{+}$ ion for our current system is estimated at $2.3\ifmmode\times\else\texttimes\fi{}{10}^{$-${}17}$. We also discuss the uncertainty evaluation of a recently reported measurement of the ${}^{88}$Sr${}^{+}$ $S$-$D$ clock transition made over a 2-month period by comparison with a maser referenced to the SI second. The frequency measured is $444\phantom{\rule{0.16em}{0ex}}779\phantom{\rule{0.16em}{0ex}}044\phantom{\rule{0.16em}{0ex}}095\phantom{\rule{0.16em}{0ex}}485.5(9)$ Hz, with an uncertainty limited by the evaluation of the maser frequency.- 7 February 2013
- Published by American Physical Society (APS) in Physical Review A
- Vol. 87 (2)
Evaluation of systematic shifts of theSrsingle-ion optical frequency standard at thelevelAn ion trap of the end-cap design was built recently at the National Research Council of Canada for improved control of the ${}^{88}$Sr${}^{+}$ single-ion optical frequency standard systematic shifts. The uncertainty on the micromotion-induced shifts is smaller by more than four orders of magnitude when compared to our previous trap system and reaches a fractional frequency uncertainty of $1\ifmmode\times\else\texttimes\fi{}{10}^{$-${}18}$. To obtain this low uncertainty level, the micromotion is minimized with trim electrodes and the trap is operated at a special frequency at which there is anticorrelation between the second-order Doppler and Stark shifts. This choice of operating frequency, determined by the differential scalar polarizability of the clock transition, yields a suppression by a factor of $$\approx${}$28 in the combined micromotion shifts. Like many optical frequency standards, the dominant source of uncertainty in the new trap is the blackbody radiation shift. Its uncertainty has been reduced by an order of magnitude with a recent theoretical evaluation of the differential scalar polarizability of the clock transition. The fractional blackbody shift uncertainty, estimated using a model of the blackbody field at the ion, is $2.2\ifmmode\times\else\texttimes\fi{}{10}^{$-${}17}$. The otherwise dominant electric quadrupole shift is reduced to below the $3\ifmmode\times\else\texttimes\fi{}{10}^{$-${}19}$ level with a cancellation method based on the average frequency of several pairs of Zeeman components. This method also cancels the tensor Stark shift and simplifies the description of the frequency shifts that are quantization-axis dependent. This paper provides a detailed description of the ${}^{88}$Sr${}^{+}$ optical frequency standard uncertainty evaluation and the methods used to make the standard robust against changes in the trap environment. The total fractional frequency uncertainty of the ${}^{88}$Sr${}^{+}$ ion for our current system is estimated at $2.3\ifmmode\times\else\texttimes\fi{}{10}^{$-${}17}$. We also discuss the uncertainty evaluation of a recently reported measurement of the ${}^{88}$Sr${}^{+}$ $S$-$D$ clock transition made over a 2-month period by comparison with a maser referenced to the SI second. The frequency measured is $444\phantom{\rule{0.16em}{0ex}}779\phantom{\rule{0.16em}{0ex}}044\phantom{\rule{0.16em}{0ex}}095\phantom{\rule{0.16em}{0ex}}485.5(9)$ Hz, with an uncertainty limited by the evaluation of the maser frequency.- 13 February 2009
- Published by Springer Nature in Applied Physics B
- Vol. 95 (1) , 43-54
A narrow linewidth and frequency-stable probe laser source for the 88Sr+ single ion optical frequency standard
- 13 February 2009
- Published by Springer Nature in Applied Physics B
- Vol. 95 (1) , 43-54
A narrow linewidth and frequency-stable probe laser source for the 88Sr+ single ion optical frequency standard
- 1 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 409-414
88Sr+ Single-Ion Optical Frequency Standard
The electric quadrupole shift is an important source of systematic uncertainty in several single-ion optical frequency standards. In this paper, we review the electric quadrupole shift cancellation method based on the Zeeman spectrum of the clock transition. The method is demonstrated with an actual frequency measurement of the 5s2S 1/2-4d2D5/2 transition of 88Sr+. This cancellation method also removes shifts from the tensor part of the Stark effect. Further analysis of the data provides an evaluation of the micromotion shifts which are then applied to correct the observed ion clock frequency. Recent improvements to our probe laser system and the observation of Fourier-transform limited linewidths of 5 Hz at 445 THz are also reported
- 1 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 409-414
88Sr+ Single-Ion Optical Frequency Standard
The electric quadrupole shift is an important source of systematic uncertainty in several single-ion optical frequency standards. In this paper, we review the electric quadrupole shift cancellation method based on the Zeeman spectrum of the clock transition. The method is demonstrated with an actual frequency measurement of the 5s2S 1/2-4d2D5/2 transition of 88Sr+. This cancellation method also removes shifts from the tensor part of the Stark effect. Further analysis of the data provides an evaluation of the micromotion shifts which are then applied to correct the observed ion clock frequency. Recent improvements to our probe laser system and the observation of Fourier-transform limited linewidths of 5 Hz at 445 THz are also reported
- 12 July 2005
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 95 (3) , 033001
Electric Quadrupole Shift Cancellation in Single-Ion Optical Frequency Standards
The electric quadrupole shift is presently the most significant source of uncertainty on the systematic shifts for several single-ion optical frequency standards. We present a simple method for canceling this shift based on measurements of the Zeeman spectrum of the clock transition. This method is easy to implement and yields very high cancellation levels. A fractional uncertainty of for the canceled quadrupole shift is estimated for a measurement of the absolute frequency of the clock transition of .- 12 July 2005
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 95 (3) , 033001
Electric Quadrupole Shift Cancellation in Single-Ion Optical Frequency Standards
The electric quadrupole shift is presently the most significant source of uncertainty on the systematic shifts for several single-ion optical frequency standards. We present a simple method for canceling this shift based on measurements of the Zeeman spectrum of the clock transition. This method is easy to implement and yields very high cancellation levels. A fractional uncertainty of for the canceled quadrupole shift is estimated for a measurement of the absolute frequency of the clock transition of .- 1 June 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 283-284
Measurement of the 88Sr+ reference transition frequency with a new probe laser system
The authors have designed and implemented a new 674 nm (445 THz) laser system for probing the ultranarrow 5s 2 S 1/2 -4d 2 D 5/2 reference (clock) transition of the trapped and laser-cooled 88 Sr + ion. The authors describe briefly the double-stage probe laser system; linewidths of (50 plusmn 9) Hz FWHM were observed for the clock transition with this source. Results on the determination of the temperature of zero thermal expansion coefficient of the reference cavity were also presented. Preliminary measurement of the absolute frequency of the 88 Sr + clock transition frequency gives a frequency of (444779044095472 plusmn 15) Hz
- 1 June 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 283-284
Measurement of the 88Sr+ reference transition frequency with a new probe laser system
The authors have designed and implemented a new 674 nm (445 THz) laser system for probing the ultranarrow 5s 2 S 1/2 -4d 2 D 5/2 reference (clock) transition of the trapped and laser-cooled 88 Sr + ion. The authors describe briefly the double-stage probe laser system; linewidths of (50 plusmn 9) Hz FWHM were observed for the clock transition with this source. Results on the determination of the temperature of zero thermal expansion coefficient of the reference cavity were also presented. Preliminary measurement of the absolute frequency of the 88 Sr + clock transition frequency gives a frequency of (444779044095472 plusmn 15) Hz
- 1 June 2004
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 21 (6) , 1113-1126
Hyperfine-structure splittings and absorption strengths of molecular-iodine transitions near the trapping frequencies of francium
Using saturated-absorption spectroscopy, we measured the hyperfine-structure splittings of four transitions in the system of near 718 nm, namely, of and The hyperfine constants and for these transitions were calculated from the measured splittings. Aided with Doppler line shapes calculated from the hyperfine splittings, and with knowledge of the relative absorption strengths of the nearby transitions from literature, we have measured the dipole moments of and from their integrated absorptions. These measurements, combined with Franck–Condon factors given in the literature, give an electronic transition dipole moment of [1.10(3) D] for the system of iodine at an R-centroid internuclear distance of 0.293 nm.- 1 June 2004
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 21 (6) , 1113-1126
Hyperfine-structure splittings and absorption strengths of molecular-iodine transitions near the trapping frequencies of francium
Using saturated-absorption spectroscopy, we measured the hyperfine-structure splittings of four transitions in the system of near 718 nm, namely, of and The hyperfine constants and for these transitions were calculated from the measured splittings. Aided with Doppler line shapes calculated from the hyperfine splittings, and with knowledge of the relative absorption strengths of the nearby transitions from literature, we have measured the dipole moments of and from their integrated absorptions. These measurements, combined with Franck–Condon factors given in the literature, give an electronic transition dipole moment of [1.10(3) D] for the system of iodine at an R-centroid internuclear distance of 0.293 nm.