AAAndrew Alexander

Andrew Alexander

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrew Alexander has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Direct aperture optimization for FLEC‐based MERT and its application in mixed beam radiotherapy

    by Andrew Alexander, Emilie Soisson, Marc‐André Renaud, Jan Seuntjens

    Purpose: Despite promising research in modulated electron radiotherapy (MERT), an applicator to produce modulated electron beams and associated treatment planning software is still not commercially available. This work investigated an optimization process in treatment planning for the McGill few leaf electron collimator (FLEC) MERT delivery device. In addition, the possibility of combining MERT with photon fields was examined to investigate mixed beam radiotherapy. Methods: A FLEC direct aperture optimization (DAO) method, in which FLEC apertures and weights were iteratively optimized was created. The authors evaluated the performance of DAO against our previous technique for generating FLEC plans and with commercially available photon beam optimization algorithms using a basic target and organ at risk geometry. The authors applied the DAO technique on a sarcoma treatment to evaluate clinical parameters. Finally, the authors examined the merit of mixing the DAO generated FLEC electron fields with photon fields to improve the dosimetry of the sarcoma treatment. Results: In relation to the alternative plans, the DAO generated sarcoma MERT plan was competitive in its ability to reduce the dose to OAR but weaker in its ability to highly conform the dose to the target volume. The addition of photon fields improved the quality of the MERT plan in terms of OAR sparing and target conformality. Conclusions: The DAO approach yielded deliverable FLEC‐based MERT plans with a limited number of fields. The approach combined with photon optimization added flexibility, where the mutual benefits of each radiation type was used in unison to improve plan quality.


  • Toward automatic field selection and planning using Monte Carlo-based direct aperture optimization in modulated electron radiotherapy

    by Andrew Alexander, François DeBlois, Jan Seuntjens

    Modulated electron radiotherapy (MERT) has been proven to produce optimal plans for shallow tumors. This study investigates automated approaches to the field determination process in generating optimal MERT plans for few-leaf electron collimator (FLEC)-based MERT, by generating a large database of pre-calculated beamlets stored as phase-space files. Beamlets can be used in an overlapping feathered pattern to reduce the effect of abutting fields, which can contribute to dose inhomogeneities within the target. Beamlet dose calculation was performed by Monte Carlo (MC) simulations prior to direct aperture optimization (DAO). The second part of the study examines a preliminary clinical comparison between FLEC-based MERT and helical TomoTherapy. A MERT plan for spinal irradiation was not able to conform to the PTV dose constraints as closely as the TomoTherapy plan, although the TomoTherapy plan was taken as is, i.e. not Monte Carlo re-calculated. Despite the remaining gradients in the PTV, the MERT plan was superior in reducing the low-dose bath typical of TomoTherapy plans. In conclusion, the FLEC-based MERT planning techniques developed within the study produced promising MERT plans with minimal user input. The phase-space database reduces the MC calculation time and the feathered field pattern improves target homogeneity. With further investigations, FLEC-based MERT will find an important niche in clinical radiation therapy.