Idrees F. Al-Momani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Idrees F. Al-Momani has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Adnan M. Massadeh
Faculty of Pharmacy, Jordan University of Science and Technology
1 shared publicationAhmed A. Alomary
Yarmouk University
1 shared publicationKamal A. Momani
Mutah University
1 shared publicationQasem M. Jaradat
Mutah University
1 shared publicationYaser A. Yousef
Yarmouk University
1 shared publication
Latest Publications
- 20 March 2008
- Published by Springer Nature in Archives of Environmental Contamination and Toxicology
- Vol. 55 (4) , 558-565
Wet and Dry Deposition Fluxes of Inorganic Chemical Species at a Rural Site in Northern Jordan
Wet and dry deposition samples were collected in a rural region in northern Jordan during the period of December 1998 to April 2000. Concentrations of 20 chemical species (Na, K, Ca, H+, Mg, NH +4 , Cl−, NO −3 , SO 2−4 ,Pb, Cd, Zn, Cu, Al, Fe, Mn, Mo, Ni, Sb, and V) were determined in collected samples. Most of the Al, Fe, Mn, Mo, Sb, and V were not soluble, whereas major ions (Na, K, Ca, H+, Mg, NH +4 , Cl−, NO −3 , and SO 2−4 ) and some trace elements (Cd, Cu, and Zn) were wet deposited mostly in the soluble form. Concentration of the soil-related elements and/or highly soluble species were washed out at the early stages of a precipitation event, and their concentrations were mostly controlled by dilution, whereas concentrations of anthropogenic species were controlled by other factors. Annual fluxes of the soil-related elements and ions were significantly higher than the primarily anthropogenic elements. This was attributed to the arid nature of the region and to the frequent input of the Saharan dust pulses.
- 20 March 2008
- Published by Springer Nature in Archives of Environmental Contamination and Toxicology
- Vol. 55 (4) , 558-565
Wet and Dry Deposition Fluxes of Inorganic Chemical Species at a Rural Site in Northern Jordan
Wet and dry deposition samples were collected in a rural region in northern Jordan during the period of December 1998 to April 2000. Concentrations of 20 chemical species (Na, K, Ca, H+, Mg, NH +4 , Cl−, NO −3 , SO 2−4 ,Pb, Cd, Zn, Cu, Al, Fe, Mn, Mo, Ni, Sb, and V) were determined in collected samples. Most of the Al, Fe, Mn, Mo, Sb, and V were not soluble, whereas major ions (Na, K, Ca, H+, Mg, NH +4 , Cl−, NO −3 , and SO 2−4 ) and some trace elements (Cd, Cu, and Zn) were wet deposited mostly in the soluble form. Concentration of the soil-related elements and/or highly soluble species were washed out at the early stages of a precipitation event, and their concentrations were mostly controlled by dilution, whereas concentrations of anthropogenic species were controlled by other factors. Annual fluxes of the soil-related elements and ions were significantly higher than the primarily anthropogenic elements. This was attributed to the arid nature of the region and to the frequent input of the Saharan dust pulses.
- 17 March 2007
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 136 (1-3) , 209-218
Atmospheric deposition of major and trace elements in Amman, Jordan
Wet and dry deposition samples were collected in the capital of Jordan, Amman. Concentrations of Al, Ba, Bi, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Sb, V, Zn, Fe, Sr, Mg2+, Ca2+, Na+, K+, Cl−, NO3 − and SO4 2−, along with pH were determined in collected samples. Mean trace metal concentrations were similar or less than those reported for other urban regions worldwide, while concentrations of Ca2+ and SO4 2− were among the highest. High Ca2+ concentrations were attributed to the calcareous nature of the local soil and to the influence of the Saharan dust. However, high SO4 2− concentrations were attributed to the influence of both anthropogenic and natural sources. Except for Cl−, NO3 −, SO4 2− and Cu, monthly dry deposition fluxes of all measured species were higher than wet deposition fluxes. The annual wet deposition fluxes of trace metals were much lower than those reported for other urban areas worldwide.
- 17 March 2007
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 136 (1-3) , 209-218
Atmospheric deposition of major and trace elements in Amman, Jordan
Wet and dry deposition samples were collected in the capital of Jordan, Amman. Concentrations of Al, Ba, Bi, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Sb, V, Zn, Fe, Sr, Mg2+, Ca2+, Na+, K+, Cl−, NO3 − and SO4 2−, along with pH were determined in collected samples. Mean trace metal concentrations were similar or less than those reported for other urban regions worldwide, while concentrations of Ca2+ and SO4 2− were among the highest. High Ca2+ concentrations were attributed to the calcareous nature of the local soil and to the influence of the Saharan dust. However, high SO4 2− concentrations were attributed to the influence of both anthropogenic and natural sources. Except for Cl−, NO3 −, SO4 2− and Cu, monthly dry deposition fluxes of all measured species were higher than wet deposition fluxes. The annual wet deposition fluxes of trace metals were much lower than those reported for other urban areas worldwide.
- 1 April 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (4) , 741-750
Flow Injection Spectrophotometric Determination of the Antibacterial Levofloxacin in Tablets and Human Urine
A sensitive and fast flow‐injection (FI) spectrophotometric method for the determination of levofloxacin based on the formation of a colored product upon oxidation with N‐bromosuccinimide (NBS) in acidic medium is proposed. Optimization of chemical and FI variables has been made. Under the optimized conditions, the sampling rate was over 90 h−1, the calibration curve obtained was linear over the range 10–300 µg·mL−1, and the detection limit was 3 µg·mL−1. The proposed method was successfully applied to the determination of levofloxacin in pharmaceuticals and human urine samples. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. Results are precise (RSD<2.7%; n =10) and in agreement with those found by the reference high pressure liquid chromatography (HPLC) procedure.
- 1 April 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (4) , 741-750
Flow Injection Spectrophotometric Determination of the Antibacterial Levofloxacin in Tablets and Human Urine
A sensitive and fast flow‐injection (FI) spectrophotometric method for the determination of levofloxacin based on the formation of a colored product upon oxidation with N‐bromosuccinimide (NBS) in acidic medium is proposed. Optimization of chemical and FI variables has been made. Under the optimized conditions, the sampling rate was over 90 h−1, the calibration curve obtained was linear over the range 10–300 µg·mL−1, and the detection limit was 3 µg·mL−1. The proposed method was successfully applied to the determination of levofloxacin in pharmaceuticals and human urine samples. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. Results are precise (RSD<2.7%; n =10) and in agreement with those found by the reference high pressure liquid chromatography (HPLC) procedure.
- 27 December 2004
- Published by Taylor & Francis in Analytical Letters
- Vol. 37 (10) , 2099-2110
Flow‐Injection Spectrophotometric Determination of Amoxcillin, Cephalexin, Ampicillin, and Cephradine in Pharmaceutical Formulations
- 27 December 2004
- Published by Taylor & Francis in Analytical Letters
- Vol. 37 (10) , 2099-2110
Flow‐Injection Spectrophotometric Determination of Amoxcillin, Cephalexin, Ampicillin, and Cephradine in Pharmaceutical Formulations