Benoît Lévesque
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Benoît Lévesque has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
R Lavoie
2 shared publicationsSylvain Allaire
2 shared publicationsD Prud'Homme
1 shared publicationDavid Bellemare
CLSC Haute-Ville, Canada
1 shared publication- Denis Gauvin
Direction de la Santé Environnementale et de la Toxicologie, Institut National de Santé Publique du Québec, 945 Avenue Wolfe, Québec, QC G1V 5B3, Canada
1 shared publication Denis Prud'Homme
1 shared publication
Latest Publications
- 23 October 2000
- Published by Taylor & Francis in Journal of Toxicology and Environmental Health, Part A
- Vol. 61 (4) , 225-243
EVALUATION OF THE HEALTH RISK ASSOCIATED WITH EXPOSURE TO CHLOROFORM IN INDOOR SWIMMING POOLS
The exposure of swimmers to chloroform (CHCl5) was investigated in indoor swimming pools of the Quebec City region along with the associated carcinogenic risk. Six training sessions involving 52 competition swimmers (11 to 20 yr old) were conducted in 3 different pools, while 12 adult leisure swimmers attended 5 sessions, each held in a different pool. For each session, water and ambient air CHCl3 concentrations were measured and CHCl3 levels in alveolar air samples (CHCl3ALV) collected from swimmers prior to entering the swimming pool premises and after 15, 35, and 60 min of swimming. Mean water concentrations varied from 18 µg/L to 80 µg/L, while those in air ranged from 78 µg/m3 to 329 µg/m3. Multiple linear regression analyses revealed that CHCl3ALV values in competition swimmers were strongly correlated to ambient air and water levels, and to a lesser degree to the intensity of training. Only ambient air concentration was positively correlated to CHCl3ALV in the leisure group. Concentrations of CHCl3 metabo lites bound to hepatic and renal macromolecules, estimated using a physiologically based pharmacokinetic (PBPK) model, were 1.6 and 1.9 times higher for the competition swimmers than for the leisure swimmers, respectively. The highest hepatic concentration predicted in competition swimmers, 0.22 µg CHCl equivalents/kg of tissue, was at least 10,000 times lower than the smallest no observed3effect level for liver tumors in animals. Data indicate that the safety margin is therefore very large, for competitive swimmers as well as for leisure swimmers.
- 23 October 2000
- Published by Taylor & Francis in Journal of Toxicology and Environmental Health, Part A
- Vol. 61 (4) , 225-243
EVALUATION OF THE HEALTH RISK ASSOCIATED WITH EXPOSURE TO CHLOROFORM IN INDOOR SWIMMING POOLS
The exposure of swimmers to chloroform (CHCl5) was investigated in indoor swimming pools of the Quebec City region along with the associated carcinogenic risk. Six training sessions involving 52 competition swimmers (11 to 20 yr old) were conducted in 3 different pools, while 12 adult leisure swimmers attended 5 sessions, each held in a different pool. For each session, water and ambient air CHCl3 concentrations were measured and CHCl3 levels in alveolar air samples (CHCl3ALV) collected from swimmers prior to entering the swimming pool premises and after 15, 35, and 60 min of swimming. Mean water concentrations varied from 18 µg/L to 80 µg/L, while those in air ranged from 78 µg/m3 to 329 µg/m3. Multiple linear regression analyses revealed that CHCl3ALV values in competition swimmers were strongly correlated to ambient air and water levels, and to a lesser degree to the intensity of training. Only ambient air concentration was positively correlated to CHCl3ALV in the leisure group. Concentrations of CHCl3 metabo lites bound to hepatic and renal macromolecules, estimated using a physiologically based pharmacokinetic (PBPK) model, were 1.6 and 1.9 times higher for the competition swimmers than for the leisure swimmers, respectively. The highest hepatic concentration predicted in competition swimmers, 0.22 µg CHCl equivalents/kg of tissue, was at least 10,000 times lower than the smallest no observed3effect level for liver tumors in animals. Data indicate that the safety margin is therefore very large, for competitive swimmers as well as for leisure swimmers.
- Open Access
- 1 February 2000
- Published by Springer Nature in Journal of Exposure Science & Environmental Epidemiology
- Vol. 10 (1) , 58-65
Air quality monitoring during indoor Monster Truck and car demolition shows
This article describes the results of air quality monitoring in an indoor ice skating rink during three Monster Truck and car demolition exhibitions, and the public health study that was carried out. The exposure of the people present to carbon monoxide and nitrogen dioxide was continuously monitored in order to determine the time-weighted average concentrations and the maximum peaks. Nitrogen dioxide concentrations were generally under the limit of detection of the device (0.5 ppm). However, carbon monoxide levels exceeded standards for workers. Maximum time-weighted average concentrations during the exhibitions were 100 parts per million with several peaks exceeding 200 parts per million (maximum value: 1600 parts per million). Recommendations were made and during a subsequent event, the carbon monoxide concentrations were reduced to protect health. Indoor exhibitions of motorized vehicles generate significant amounts of combustion gases, which can be a health hazard. There must be sufficient ventilation and the carbon monoxide and nitrogen dioxide concentrations must be monitored. In addition, the motors of the most polluting vehicles should be adjusted before the events in order to limit the emission of combustion products. If these steps are not met, the events should be held outdoors.
- 1 February 2000
- Published by Springer Nature in Journal of Exposure Science & Environmental Epidemiology
- Vol. 10 (1) , 58-65
Open AccessAir quality monitoring during indoor Monster Truck and car demolition shows
This article describes the results of air quality monitoring in an indoor ice skating rink during three Monster Truck and car demolition exhibitions, and the public health study that was carried out. The exposure of the people present to carbon monoxide and nitrogen dioxide was continuously monitored in order to determine the time-weighted average concentrations and the maximum peaks. Nitrogen dioxide concentrations were generally under the limit of detection of the device (0.5 ppm). However, carbon monoxide levels exceeded standards for workers. Maximum time-weighted average concentrations during the exhibitions were 100 parts per million with several peaks exceeding 200 parts per million (maximum value: 1600 parts per million). Recommendations were made and during a subsequent event, the carbon monoxide concentrations were reduced to protect health. Indoor exhibitions of motorized vehicles generate significant amounts of combustion gases, which can be a health hazard. There must be sufficient ventilation and the carbon monoxide and nitrogen dioxide concentrations must be monitored. In addition, the motors of the most polluting vehicles should be adjusted before the events in order to limit the emission of combustion products. If these steps are not met, the events should be held outdoors.
- 1 September 1993
- Vol. 84 (5) , 350-1
[Anti-tobacco day at the hospital: factors associated with smoking cessation].
- 1 September 1993
- Vol. 84 (5) , 350-1
[Anti-tobacco day at the hospital: factors associated with smoking cessation].
- 1 February 1991
- Vol. 33 (1) , 5-8
An experiment to evaluate carbon monoxide absorption by hockey players in ice skating rinks.
Carbon monoxide (CO) released from the exhaust of ice resurfacing machinery is frequently found in indoor ice skating rinks. We conducted a study with 14 male adult non-smokers unexposed occupationally, who played hockey games in 4 different atmospheric CO concentrations. To document absorption, we measured their alveolar CO (alvCO). Exposure was the average CO level in the rink during the game. Environmental concentrations were between 0.0 (undetected) and 76.2 parts per million (ppm). The exposure-absorption relationship was linear (regression parameters: r2 = 0.93, slope = 0.411, intercept = -1.45). This means that for each 10 ppm of CO in the indoor air, the players absorbed enough CO to raise their alvCO by 4.1 ppm (approximately 0.76% carboxyhemoglobin). Taking into account the duration of the games, the regression coefficients were almost similar to those of an earlier study we made with 122 adult male hockey players playing in recreational leagues of the Quebec city area. These results show the exposure-absorption relationship for an acute 60-minute exposure, in a design which eliminated certain of the uncontrolled variables of our first study. It also emphasizes the importance of prevention for CO pollution in indoor skating rinks.
- 1 February 1991
- Vol. 33 (1) , 5-8
An experiment to evaluate carbon monoxide absorption by hockey players in ice skating rinks.
Carbon monoxide (CO) released from the exhaust of ice resurfacing machinery is frequently found in indoor ice skating rinks. We conducted a study with 14 male adult non-smokers unexposed occupationally, who played hockey games in 4 different atmospheric CO concentrations. To document absorption, we measured their alveolar CO (alvCO). Exposure was the average CO level in the rink during the game. Environmental concentrations were between 0.0 (undetected) and 76.2 parts per million (ppm). The exposure-absorption relationship was linear (regression parameters: r2 = 0.93, slope = 0.411, intercept = -1.45). This means that for each 10 ppm of CO in the indoor air, the players absorbed enough CO to raise their alvCO by 4.1 ppm (approximately 0.76% carboxyhemoglobin). Taking into account the duration of the games, the regression coefficients were almost similar to those of an earlier study we made with 122 adult male hockey players playing in recreational leagues of the Quebec city area. These results show the exposure-absorption relationship for an acute 60-minute exposure, in a design which eliminated certain of the uncontrolled variables of our first study. It also emphasizes the importance of prevention for CO pollution in indoor skating rinks.