Silvana Moreira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Silvana Moreira has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Ana Elisa S. Vives
Methodist University of Piracicaba , Piracicaba, SP, Brazil
1 shared publication- Andre Pereira de Almeida
Laboratory of Nuclear Instrumentation, COPPE/UFRJ, P.O. Box 68509, 21941-972 Rio de Janeiro, RJ, Brazil
1 shared publication Bruna Fernanda de Faria
University of Campinas Civil Engineering College PO Box 6021 13083‐952 Campinas São Paulo Brazil
1 shared publicationC. Vázquez
Comisión Nacional de Energía Atómica, Av. del Libertador 8250, 1429 Buenos Aires, Argentina
1 shared publication- Carolina de Souza-Guerra
Dental School of Piracicaba, State University of Campinas, FOP/UNICAMP, P.O. Box 13414-903, Piracicaba, SP, Brazil
1 shared publication Edgar F. O. de Jesus
Federal University of Rio de Janeiro , Rio de Janeiro, RJ, Brazil
1 shared publication
Latest Publications
- 14 May 2013
- Published by Wiley in X-Ray Spectrometry
- Vol. 42 (4) , 290-298
Study of main and signature sources of particulate matter pollutants in Limeira City (Brazil) using SR‐TXRF
The study's objective was to identify the main generating sources of particulate matter from the Limeira City (SP), Brazil. Particulate matter collections were carried out at the meteorological station of the Technology Department of Campinas State University by using a sequential filtration sampling system. Using synchrotron radiation total reflection X‐ray fluorescence makes it possible to perform quality quantitative analysis of the particulate matter collected during the years 2008 and 2009. Respirable particulate matter's coarse and fine fractions that affect the upper and lower respiratory tract were collected on polycarbonate filters arranged in series. At the Brazilian Synchrotron Light Laboratory, samples were analyzed by synchrotron radiation total reflection X‐ray fluorescence after removal from acid. Results indicated that the coarse fraction made the greatest contribution to PM 10 formation. As per the particulate matter composition, 16 elements were found in both fractions: S, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Ba, and Pb. The determination of the probable emission sources contributing to the formation of particulate material was possible by applying multivariate statistical analyses, namely principal components analysis and cluster analysis. The primary emission source for the coarse fraction was soil dust, which contributed 57%, followed by 30% from vehicular emissions, and lastly, only 13% from industrial emissions. The primary emission source for the fine fraction was soil dust, which contributed 79%, followed by 13% from vehicular emissions, and lastly, only 8% from industrial emissions. Copyright © 2013 John Wiley & Sons, Ltd.
- 14 May 2013
- Published by Wiley in X-Ray Spectrometry
- Vol. 42 (4) , 290-298
Study of main and signature sources of particulate matter pollutants in Limeira City (Brazil) using SR‐TXRF
The study's objective was to identify the main generating sources of particulate matter from the Limeira City (SP), Brazil. Particulate matter collections were carried out at the meteorological station of the Technology Department of Campinas State University by using a sequential filtration sampling system. Using synchrotron radiation total reflection X‐ray fluorescence makes it possible to perform quality quantitative analysis of the particulate matter collected during the years 2008 and 2009. Respirable particulate matter's coarse and fine fractions that affect the upper and lower respiratory tract were collected on polycarbonate filters arranged in series. At the Brazilian Synchrotron Light Laboratory, samples were analyzed by synchrotron radiation total reflection X‐ray fluorescence after removal from acid. Results indicated that the coarse fraction made the greatest contribution to PM 10 formation. As per the particulate matter composition, 16 elements were found in both fractions: S, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Ba, and Pb. The determination of the probable emission sources contributing to the formation of particulate material was possible by applying multivariate statistical analyses, namely principal components analysis and cluster analysis. The primary emission source for the coarse fraction was soil dust, which contributed 57%, followed by 30% from vehicular emissions, and lastly, only 13% from industrial emissions. The primary emission source for the fine fraction was soil dust, which contributed 79%, followed by 13% from vehicular emissions, and lastly, only 8% from industrial emissions. Copyright © 2013 John Wiley & Sons, Ltd.
- 1 October 2006
- Published by Taylor & Francis in Instrumentation Science & Technology
- Vol. 34 (5) , 567-585
Heavy Metals in Groundwater using Synchrotron Radiation Total Reflection X‐Ray Analysis
The environmental pollution problem has increased due to industrial and population growth. São Paulo and Campinas are examples of large urban centers that have grown in a disorderly manner and, today, present contamination problems which have also reached the groundwater. In order to obtain information about levels of heavy metals in groundwater, analyses were carried out with samples from well monitoring at Landfill Pirelli in Campinas and in some supplying wells in the Campinas region which are, in their majority, wells of industrial supply. The analytical technique used for achievement of the analysis is total reflection X‐ray fluorescence with synchrotron radiation. All measurements were performed at Synchrotron Light Source Laboratory, located in Campinas, São Paulo, Brazil. The determined elements in this research were Al, Fe, Mn, Cu, Cr, Ni, Zn, Ba, and Pb. The results were compared with the maximum permitted values (MPV) established by the Brazilian Health Department and, for Landfill Pirelli, the concentrations were higher than the permitted values for Ba and Pb, as was expected, because this landfill received residues during many years without control. In well supply, as in State University of Campinas (UNICAMP), elements such as Cr and Pb were not expected, so the monitoring of these wells is necessary in order to verify if these elements continue to be detected with values above the permitted values. The same elements were also detected in other supplying wells in the Campinas metropolitan region. For lead (Pb), values above the maximum were observed in 15 wells. The detection limits obtained varyied from 0.10 µg · L−1 to 7.91 µg · L−1 and were in agreement with the values presented by other analytical techniques.
- 1 October 2006
- Published by Taylor & Francis in Instrumentation Science & Technology
- Vol. 34 (5) , 567-585
Heavy Metals in Groundwater using Synchrotron Radiation Total Reflection X‐Ray Analysis
The environmental pollution problem has increased due to industrial and population growth. São Paulo and Campinas are examples of large urban centers that have grown in a disorderly manner and, today, present contamination problems which have also reached the groundwater. In order to obtain information about levels of heavy metals in groundwater, analyses were carried out with samples from well monitoring at Landfill Pirelli in Campinas and in some supplying wells in the Campinas region which are, in their majority, wells of industrial supply. The analytical technique used for achievement of the analysis is total reflection X‐ray fluorescence with synchrotron radiation. All measurements were performed at Synchrotron Light Source Laboratory, located in Campinas, São Paulo, Brazil. The determined elements in this research were Al, Fe, Mn, Cu, Cr, Ni, Zn, Ba, and Pb. The results were compared with the maximum permitted values (MPV) established by the Brazilian Health Department and, for Landfill Pirelli, the concentrations were higher than the permitted values for Ba and Pb, as was expected, because this landfill received residues during many years without control. In well supply, as in State University of Campinas (UNICAMP), elements such as Cr and Pb were not expected, so the monitoring of these wells is necessary in order to verify if these elements continue to be detected with values above the permitted values. The same elements were also detected in other supplying wells in the Campinas metropolitan region. For lead (Pb), values above the maximum were observed in 15 wells. The detection limits obtained varyied from 0.10 µg · L−1 to 7.91 µg · L−1 and were in agreement with the values presented by other analytical techniques.
- 6 March 2002
- Published by Wiley in X-Ray Spectrometry
- Vol. 31 (2) , 167-172
Total reflection by synchrotron radiation: trace determination in nuclear materials
The chemical control of impurities in nuclear materials is indispensable in order to ensure efficient operation of the reactors. The maximum concentration admitted depends on the elements and in most cases is in the parts per billion range. Conventional analytical methods require a preconcentration treatment of the sample and a previous separation of the matrix (uranium). In this work, we investigated the use of total reflection x‐ray fluorescence with synchrotron radiation excitation as an alternative methodology for the determination of impurities in nuclear materials, namely K, Ca, Ti, Cr, Mn, Fe, Ni, Cu and As. The detection limits obtained were in the range 0.1–20 ng ml −1 for a 1000 s counting time. Copyright © 2002 John Wiley & Sons, Ltd.
- 6 March 2002
- Published by Wiley in X-Ray Spectrometry
- Vol. 31 (2) , 167-172
Total reflection by synchrotron radiation: trace determination in nuclear materials
The chemical control of impurities in nuclear materials is indispensable in order to ensure efficient operation of the reactors. The maximum concentration admitted depends on the elements and in most cases is in the parts per billion range. Conventional analytical methods require a preconcentration treatment of the sample and a previous separation of the matrix (uranium). In this work, we investigated the use of total reflection x‐ray fluorescence with synchrotron radiation excitation as an alternative methodology for the determination of impurities in nuclear materials, namely K, Ca, Ti, Cr, Mn, Fe, Ni, Cu and As. The detection limits obtained were in the range 0.1–20 ng ml −1 for a 1000 s counting time. Copyright © 2002 John Wiley & Sons, Ltd.