Ulrich Tallarek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ulrich Tallarek has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Dzmitry Hlushkou
Institut für Verfahrenstechnik, Otto-von-Guericke-Universität Magdeburg , Magdeburg, Germany ; Department of Systems Analysis , Belarusian State University , Minsk, Republic of Belarus
2 shared publications- Erdmann Rapp
Bioprocess Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Magdeburg, Germany
2 shared publications Ivo Nischang
Institut für Verfahrenstechnik, Otto-von-Guericke-Universität, Magdeburg, Germany
2 shared publicationsA. G. Hoekstra
Section Computational Science, Faculty of Science, University of Amsterdam, Kruislaan 403 1098 SJ Amsterdam, The Netherlands
1 shared publicationAlexandra Höltzel
Institut für Verfahrenstechnik, Otto-von-Guericke-Universität, Magdeburg, Germany
1 shared publication- Andreas Seidel-Morgenstern
Max Planck Institute for Dynamics of Complex Technical Systems, Magdeburg, Germany
1 shared publication
Latest Publications
- 29 June 2007
- Published by Wiley in Journal of Separation Science
- Vol. 30 (10) , 1398-1419
Ionic conductance of nanopores in microscale analysis systems: Where microfluidics meets nanofluidics
In this tutorial review we illustrate the origin and dependence on various system parameters of the ionic conductance that exists in discrete nanochannels as well as in nanoporous separation and preconcentration units contained as hybrid configurations, membranes, packed beds, or monoliths in microscale liquid phase analysis systems. A particular complexity arises as external electrical fields are superimposed on internal chemical and electrical potential gradients for tailoring molecular transport. It is demonstrated that the variety of geometries in which the microfluidic/nanofluidic interfaces are realized share common, fundamental features of coupled mass and charge transport, but that phenomena behind the key steps in a particular application can be significantly tuned, depending on the morphology of a material. Thus, the understanding of morphology‐related transport in internal and external electrical potential gradients is critical to the performance of a device. This addresses a variety of geometries (slits, channels, filters, membranes, random or regular networks of pores, etc.) and applications, e. g., the gating, sensing, preconcentration, and separation in multifunctional miniaturized devices. Inherently coupled mass and charge transport through ion‐permselective (charge‐selective) microfluidic/nanofluidic interfaces is analyzed with a stepwise‐added complexity and discussed with respect to the morphology of the charge‐selective spatial domains. Within this scenario, the electrostatics and electrokinetics in microfluidic and nanofluidic channels, as well as the electrohydrodynamics evolving at microfluidic/nanofluidic interfaces, where microfluidics meets nanofluidics, define the platform of central phenomena.
- 29 June 2007
- Published by Wiley in Journal of Separation Science
- Vol. 30 (10) , 1398-1419
Ionic conductance of nanopores in microscale analysis systems: Where microfluidics meets nanofluidics
In this tutorial review we illustrate the origin and dependence on various system parameters of the ionic conductance that exists in discrete nanochannels as well as in nanoporous separation and preconcentration units contained as hybrid configurations, membranes, packed beds, or monoliths in microscale liquid phase analysis systems. A particular complexity arises as external electrical fields are superimposed on internal chemical and electrical potential gradients for tailoring molecular transport. It is demonstrated that the variety of geometries in which the microfluidic/nanofluidic interfaces are realized share common, fundamental features of coupled mass and charge transport, but that phenomena behind the key steps in a particular application can be significantly tuned, depending on the morphology of a material. Thus, the understanding of morphology‐related transport in internal and external electrical potential gradients is critical to the performance of a device. This addresses a variety of geometries (slits, channels, filters, membranes, random or regular networks of pores, etc.) and applications, e. g., the gating, sensing, preconcentration, and separation in multifunctional miniaturized devices. Inherently coupled mass and charge transport through ion‐permselective (charge‐selective) microfluidic/nanofluidic interfaces is analyzed with a stepwise‐added complexity and discussed with respect to the morphology of the charge‐selective spatial domains. Within this scenario, the electrostatics and electrokinetics in microfluidic and nanofluidic channels, as well as the electrohydrodynamics evolving at microfluidic/nanofluidic interfaces, where microfluidics meets nanofluidics, define the platform of central phenomena.
- 14 February 2007
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 388 (3) , 517-520
High-pressure liquid chromatography in lab-on-a-chip devices
- 14 February 2007
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 388 (3) , 517-520
High-pressure liquid chromatography in lab-on-a-chip devices
- 1 July 2006
- Published by Taylor & Francis in Chemical Engineering Communications
- Vol. 193 (7) , 826-839
NUMERICAL SIMULATION OF ELECTROKINETIC MICROFLUIDICS IN COLLOIDAL SYSTEMS
A numerical scheme is presented for simulating electrokinetic microfluidics in systems with arbitrary morphology. This scheme is based on a numerical solution of the coupled Poisson, Nernst–Planck, and Navier–Stokes equations. While traditional finite-difference methods were used to resolve the first two problems, the lattice Boltzmann method was applied to the latter. The developed numerical approach was used for the simulation of electroosmotic flow through a simple cubic array of hard (impermeable, nonconducting) micro-sized spheres. Volumetric electroosmotic flow was studied for dependence on electrical field strength, ζ-potential at the solid-liquid interface, electrical double layer interaction, and numerical grid resolution. Colloid stability and electrokinetics in microfluidic devices with particulate or monolithic fixed-bed elements represent two potential applications of this work.
- 1 July 2006
- Published by Taylor & Francis in Chemical Engineering Communications
- Vol. 193 (7) , 826-839
NUMERICAL SIMULATION OF ELECTROKINETIC MICROFLUIDICS IN COLLOIDAL SYSTEMS
A numerical scheme is presented for simulating electrokinetic microfluidics in systems with arbitrary morphology. This scheme is based on a numerical solution of the coupled Poisson, Nernst–Planck, and Navier–Stokes equations. While traditional finite-difference methods were used to resolve the first two problems, the lattice Boltzmann method was applied to the latter. The developed numerical approach was used for the simulation of electroosmotic flow through a simple cubic array of hard (impermeable, nonconducting) micro-sized spheres. Volumetric electroosmotic flow was studied for dependence on electrical field strength, ζ-potential at the solid-liquid interface, electrical double layer interaction, and numerical grid resolution. Colloid stability and electrokinetics in microfluidic devices with particulate or monolithic fixed-bed elements represent two potential applications of this work.
- 19 January 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (2) , 391-404
Perspective on concentration polarization effects in electrochromatographic separations
This work illustrates the appearance and electrohydrodynamic consequences of concentration polarization in the particulate and monolithic fixed beds used in capillary electrochromatography and related electrical‐field assisted processes. Key property of most porous materials is the co‐existence of bulk, quasi‐electroneutral macroporous regions and mesoporous compartments which are ion‐permselective (due to electrical double‐layer overlap) causing different transport numbers for co‐ionic and counterionic species, e.g., background electrolyte components, or the analytes. For a cathodic electroosmotic flow the (cation) permselectivity, together with diffusive and electrokinetic transport induces depleted and enriched concentration polarization zones at the anodic and cathodic interfaces, respectively, in dependence of the mobile phase ionic strength and applied electrical fields. At high field strength a secondary, nonequilibrium electrical double layer may be created in the depleted concentration polarization zones of a material stimulating electroosmosis of the second kind. The potential of this induced‐charge electroosmosis with respect to nonlinear flow velocities and electrokinetic instability mixing (basically destroying the concentration polarization zones) is analyzed in view of the pore space morphology in random‐close packings of spherical‐shaped, porous particles and hierarchically structured monoliths. Possible applications based on a fine‐tuning of the illustrated effects emerge for microfluidic pumping and mixing, or the intensification of sample recovery in adsorption processes. With this perspective we want to focus the attention on concentration polarization in electrochromatographic systems by presenting and discussing original data acquired on relevant microscopic as well as macroscopic scales, and point towards the importance of related effects in colloid and membrane science.*
- 19 January 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (2) , 391-404
Perspective on concentration polarization effects in electrochromatographic separations
This work illustrates the appearance and electrohydrodynamic consequences of concentration polarization in the particulate and monolithic fixed beds used in capillary electrochromatography and related electrical‐field assisted processes. Key property of most porous materials is the co‐existence of bulk, quasi‐electroneutral macroporous regions and mesoporous compartments which are ion‐permselective (due to electrical double‐layer overlap) causing different transport numbers for co‐ionic and counterionic species, e.g., background electrolyte components, or the analytes. For a cathodic electroosmotic flow the (cation) permselectivity, together with diffusive and electrokinetic transport induces depleted and enriched concentration polarization zones at the anodic and cathodic interfaces, respectively, in dependence of the mobile phase ionic strength and applied electrical fields. At high field strength a secondary, nonequilibrium electrical double layer may be created in the depleted concentration polarization zones of a material stimulating electroosmosis of the second kind. The potential of this induced‐charge electroosmosis with respect to nonlinear flow velocities and electrokinetic instability mixing (basically destroying the concentration polarization zones) is analyzed in view of the pore space morphology in random‐close packings of spherical‐shaped, porous particles and hierarchically structured monoliths. Possible applications based on a fine‐tuning of the illustrated effects emerge for microfluidic pumping and mixing, or the intensification of sample recovery in adsorption processes. With this perspective we want to focus the attention on concentration polarization in electrochromatographic systems by presenting and discussing original data acquired on relevant microscopic as well as macroscopic scales, and point towards the importance of related effects in colloid and membrane science.*
- 30 August 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (17) , 2935-2945
Nonlinear electroosmosis in hierarchical monolithic structures
We studied the dependence of electroosmotic flow (EOF) velocity and separation efficiency for neutral analytes in 100 μm ID capillary monoliths on a variation of the mobile phase ionic strength and applied electrical field strength, i.e., we covered a range for the concentration of Tris buffer from 10−5 to 10−2 M and applied electrical field strengths up to 105 V/m. The silica-based monoliths are hierarchically structured having intraskeleton mesopores and interskeleton macropores. While a linear dependence of the average EOF velocity on applied field strength could be observed with 5×10−3 M Tris (turning slightly nonlinear at a higher concentration due to thermal effects), this dependence becomes systematically nonlinear as the Tris concentration is reduced towards 10−4 M. Increased velocities by more than 50% compared to those expected from linear behavior are realized at 105 V/m. Concomitantly, as the Tris concentration is reduced from 10−3 to 10−4 M, we notice an improvement in plate heights by a factor of more than 2 (they approach 2 μm for ethylbenzoate). We complementary analyzed the onset of the nonlinear EOF dynamics in a hierarchical monolith and the significantly reduced axial dispersion in view of nonequilibrium electrokinetic effects which may develop in porous media due to the presence of ion-permselective regions, e.g., the mesoporous monolith skeleton. In this respect, a decreasing mobile phase ionic strength favors the formation of nonequilibrium concentration polarization in strong electrical fields, and a coupling of the electrostatics and hydrodynamics then may explain nonlinear EOF velocities and increasing separation efficiencies depending on the Tris concentration and applied field strength.
- 30 August 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (17) , 2935-2945
Nonlinear electroosmosis in hierarchical monolithic structures
We studied the dependence of electroosmotic flow (EOF) velocity and separation efficiency for neutral analytes in 100 μm ID capillary monoliths on a variation of the mobile phase ionic strength and applied electrical field strength, i.e., we covered a range for the concentration of Tris buffer from 10−5 to 10−2 M and applied electrical field strengths up to 105 V/m. The silica-based monoliths are hierarchically structured having intraskeleton mesopores and interskeleton macropores. While a linear dependence of the average EOF velocity on applied field strength could be observed with 5×10−3 M Tris (turning slightly nonlinear at a higher concentration due to thermal effects), this dependence becomes systematically nonlinear as the Tris concentration is reduced towards 10−4 M. Increased velocities by more than 50% compared to those expected from linear behavior are realized at 105 V/m. Concomitantly, as the Tris concentration is reduced from 10−3 to 10−4 M, we notice an improvement in plate heights by a factor of more than 2 (they approach 2 μm for ethylbenzoate). We complementary analyzed the onset of the nonlinear EOF dynamics in a hierarchical monolith and the significantly reduced axial dispersion in view of nonequilibrium electrokinetic effects which may develop in porous media due to the presence of ion-permselective regions, e.g., the mesoporous monolith skeleton. In this respect, a decreasing mobile phase ionic strength favors the formation of nonequilibrium concentration polarization in strong electrical fields, and a coupling of the electrostatics and hydrodynamics then may explain nonlinear EOF velocities and increasing separation efficiencies depending on the Tris concentration and applied field strength.
- 18 August 2004
- Published by Wiley in International Journal for Numerical Methods in Fluids
- Vol. 46 (5) , 507-532
Coupled lattice‐Boltzmann and finite‐difference simulation of electroosmosis in microfluidic channels
In this article we are concerned with an extension of the lattice‐Boltzmann method for the numerical simulation of three‐dimensional electroosmotic flow problems in porous media. Our description is evaluated using simple geometries as those encountered in open‐channel microfluidic devices. In particular, we consider electroosmosis in straight cylindrical capillaries with a (non)uniform zeta‐potential distribution for ratios of the capillary inner radius to the thickness of the electrical double layer from 10 to 100. The general case of heterogeneous zeta‐potential distributions at the surface of a capillary requires solution of the following coupled equations in three dimensions: Navier–Stokes equation for liquid flow, Poisson equation for electrical potential distribution, and the Nernst–Planck equation for distribution of ionic species. The hydrodynamic problem has been treated with high efficiency by code parallelization through the lattice‐Boltzmann method. For validation velocity fields were simulated in several microcapillary systems and good agreement with results predicted either theoretically or obtained by alternative numerical methods could be established. Results are also discussed with respect to the use of a slip boundary condition for the velocity field at the surface. Copyright © 2004 John Wiley & Sons, Ltd.
- 18 August 2004
- Published by Wiley in International Journal for Numerical Methods in Fluids
- Vol. 46 (5) , 507-532
Coupled lattice‐Boltzmann and finite‐difference simulation of electroosmosis in microfluidic channels
In this article we are concerned with an extension of the lattice‐Boltzmann method for the numerical simulation of three‐dimensional electroosmotic flow problems in porous media. Our description is evaluated using simple geometries as those encountered in open‐channel microfluidic devices. In particular, we consider electroosmosis in straight cylindrical capillaries with a (non)uniform zeta‐potential distribution for ratios of the capillary inner radius to the thickness of the electrical double layer from 10 to 100. The general case of heterogeneous zeta‐potential distributions at the surface of a capillary requires solution of the following coupled equations in three dimensions: Navier–Stokes equation for liquid flow, Poisson equation for electrical potential distribution, and the Nernst–Planck equation for distribution of ionic species. The hydrodynamic problem has been treated with high efficiency by code parallelization through the lattice‐Boltzmann method. For validation velocity fields were simulated in several microcapillary systems and good agreement with results predicted either theoretically or obtained by alternative numerical methods could be established. Results are also discussed with respect to the use of a slip boundary condition for the velocity field at the surface. Copyright © 2004 John Wiley & Sons, Ltd.
- 12 December 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (24) , 4241-4253
Perfusive flow and intraparticle distribution of a neutral analyte in capillary electrochromatography
The relevance and magnitude of an electroosmotic perfusion mechanism in electrochromatography is analyzed. To systemize our studies we first considered the transport of an electroneutral and nonadsorbing tracer. Based on the refractive index matching in a microfluidic setup containing fixed spherical porous particles, we conducted a quantitative analysis in real time of the spatio‐temporal distribution of fluorescent tracer molecules during their uptake by (and a release from) single particles using confocal laser scanning microscopy. Even under conditions of a significant electrical double layer overlap the intraparticle electroosmotic flow produces due to its unidirectional nature and in striking contrast to the symmetric (spherical) distributions typical for purely diffusive transport strongly asymmetric concentration profiles inside spherical particles as the locally charged pore liquid begins to respond to the externally applied electrical field. The profiles retain an axisymmetric nature, i.e., rotational symmetry with respect to the field direction. Results of our measurements could be successfully interpreted and further analyzed by a compact mathematical model. Intraparticle Peclet numbers of up to 150 have been realized and found to significantly enhance the mass transport on particle scale towards the convection‐dominated regime when compared to a conventional (diffusion‐limited) kinetics.
- 12 December 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (24) , 4241-4253
Perfusive flow and intraparticle distribution of a neutral analyte in capillary electrochromatography
The relevance and magnitude of an electroosmotic perfusion mechanism in electrochromatography is analyzed. To systemize our studies we first considered the transport of an electroneutral and nonadsorbing tracer. Based on the refractive index matching in a microfluidic setup containing fixed spherical porous particles, we conducted a quantitative analysis in real time of the spatio‐temporal distribution of fluorescent tracer molecules during their uptake by (and a release from) single particles using confocal laser scanning microscopy. Even under conditions of a significant electrical double layer overlap the intraparticle electroosmotic flow produces due to its unidirectional nature and in striking contrast to the symmetric (spherical) distributions typical for purely diffusive transport strongly asymmetric concentration profiles inside spherical particles as the locally charged pore liquid begins to respond to the externally applied electrical field. The profiles retain an axisymmetric nature, i.e., rotational symmetry with respect to the field direction. Results of our measurements could be successfully interpreted and further analyzed by a compact mathematical model. Intraparticle Peclet numbers of up to 150 have been realized and found to significantly enhance the mass transport on particle scale towards the convection‐dominated regime when compared to a conventional (diffusion‐limited) kinetics.
- 9 May 2003
- Published by Wiley in Journal of Separation Science
- Vol. 26 (6-7) , 453-470
Liquid flow in capillary (electro)chromatography: Generation and control of micro‐ and nanoliter volumes
We describe and discuss instrumental developments in capillary (electro)chromatography which are of particular relevance for generating (and controlling) required volumetric flow rates in the micro‐ and nanoliter range through packed capillaries. Both isocratic and gradient elution are considered. For capillary HPLC this practically involves only commercial instrumentation, with systems based on syringe or piston pumps, but it also realizes the innovative concept of a high‐pressure electrokinetic pump. The numerous systems that have been used to generate electroosmotic flow through chromatographic beds are classified under the following headings: i) basically commercial capillary electrophoresis instruments (adapted for electrochromatography); ii) home‐built configurations; and iii) commercial capillary electrochromatography systems. Concerning the reviewed instrumentation, emphasis is placed on feasibility, automation, as well as system‐inherent delay times and dead volumes.
- 9 May 2003
- Published by Wiley in Journal of Separation Science
- Vol. 26 (6-7) , 453-470
Liquid flow in capillary (electro)chromatography: Generation and control of micro‐ and nanoliter volumes
We describe and discuss instrumental developments in capillary (electro)chromatography which are of particular relevance for generating (and controlling) required volumetric flow rates in the micro‐ and nanoliter range through packed capillaries. Both isocratic and gradient elution are considered. For capillary HPLC this practically involves only commercial instrumentation, with systems based on syringe or piston pumps, but it also realizes the innovative concept of a high‐pressure electrokinetic pump. The numerous systems that have been used to generate electroosmotic flow through chromatographic beds are classified under the following headings: i) basically commercial capillary electrophoresis instruments (adapted for electrochromatography); ii) home‐built configurations; and iii) commercial capillary electrochromatography systems. Concerning the reviewed instrumentation, emphasis is placed on feasibility, automation, as well as system‐inherent delay times and dead volumes.
- 24 May 2002
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 88 (23) , 234501
Influence of Stagnant Zones on Transient and Asymptotic Dispersion in Macroscopically Homogeneous Porous Media
The role of stagnant zones in hydrodynamic dispersion is studied for creeping flow through a fixed bed of spherical permeable particles, covering several orders of characteristic time and length scales associated with fluid transport. Numerical simulations employ a hierarchical model to cope with the different temporal and spatial scales, showing good agreement with our experimental results on diffusion-limited mass transfer, transient, and asymptotic longitudinal dispersion. These data demonstrate that intraparticle liquid holdup in macroscopically homogeneous porous media clearly dominates over contributions caused by the intrinsic flow field heterogeneity and boundary-layer mass transfer.
- 24 May 2002
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 88 (23) , 234501
Influence of Stagnant Zones on Transient and Asymptotic Dispersion in Macroscopically Homogeneous Porous Media
The role of stagnant zones in hydrodynamic dispersion is studied for creeping flow through a fixed bed of spherical permeable particles, covering several orders of characteristic time and length scales associated with fluid transport. Numerical simulations employ a hierarchical model to cope with the different temporal and spatial scales, showing good agreement with our experimental results on diffusion-limited mass transfer, transient, and asymptotic longitudinal dispersion. These data demonstrate that intraparticle liquid holdup in macroscopically homogeneous porous media clearly dominates over contributions caused by the intrinsic flow field heterogeneity and boundary-layer mass transfer.