GKGlenn W. Knox

Glenn W. Knox

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Glenn W. Knox has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Cathy DiBiase

    Bionetics Corporation, NASA-Kennedy Space Center , FL

    1 shared publication
  • Daniel Woodard

    Bionetics Corporation, NASA-Kennedy Space Center , FL

    1 shared publication
  • Glenn W. M.D.

    University of Florida Shands/Jacksonville, Jacksonville, Florida, U.S.A. [ protected

    1 shared publication
  • Harlan Reitan

    Northeast Florida Ear Research Institute, University of Florida and Gyrns LLC, Jacksonville, Florida, U.S.A.

    1 shared publication
  • J.D.

    University of Florida Shands/Jacksonville, Jacksonville, Florida, U.S.A. [ protected

    1 shared publication
  • Knox

    University of Florida Shands/Jacksonville, Jacksonville, Florida, U.S.A. [ protected

    1 shared publication

Latest Publications

  • Open Access

    Off-Vertical Axis Rotational Assessment of Transdermal Scopolamine for Motion Sickness Prophylaxis

    by Daniel Woodard, Glenn Knox, Scott Wood, Cathy DiBiase

    The objectives of this study were to evaluate transdermal scopolamine for motion sickness prophylaxis, and to evaluate off-vertical axis rotation (OVAR) as a laboratory model of motion sickness. This was a randomized, prospective, double-blind study design, set in a vestibular research laboratory. The experimental subjects consisted of 12 patients – 7 male, 5 female – ages 21 to 57, with normal auditory/vestibular function. The intervention was off-vertical axis rotation 20 degrees in the dark after administration of transdermal scopolamine or placebo. The main outcome measures were time duration of tolerated off-vertical rotation, and subjective symptom reporting during rotation at one-minute intervals on a 0–4 scale. Results were as follows: patients treated with transdermal scopolamine had statistically significant improved tolerance time to off-vertical axis rotation. Reported symptom-atology on the 0–4 subjective symptom scale was significantly improved, as compared to placebo, and was dose-dependent. Conclusions are as follows: off-vertical axis rotation is a useful modality for the evaluation of motion sickness medications. Transdermal scopolamine showed statistically significant dose-dependent effects in mitigating OVAR-induced motion sickness symptomatology and was well tolerated.

  • Motion sickness: an evolutionary and genetic basis for the negative reinforcement model.

    by Glenn W. Knox

    Knox GW. Motion sickness: an evolutionary and genetic basis for the negative reinforcement model. Aviat Space Environ Med 2013; 84:46–9. It has been theorized that motion sickness evolved as a negative reinforcement system which terminates motion involving postural instability and/or sensory conflict. A hypothetical example is provided by a “thought experiment” whereby protohominids are in a tree looking for food. Selection pressure results when the organisms that have an aversion to motion-producing sensory conflict do not venture out too far on the tree limbs and therefore tend to survive. In order to support an evolutionary model for motion sickness there must be evidence for genetic and/or heritable predisposition. The present study involves a retrospective literature review which reveals abundant evidence for genetic/heritable factors in motion sickness. Examples include genetic polymorphism of the alpha-2-adrenergic receptor, which has been shown to increase susceptibility to motion sickness, examination of family trees revealing heritable motion sickness susceptibility, evidence indicating that Asians are hyper-susceptible to motion sickness, and twin studies, just to mention a few. Thus, the theory of heritable negative reinforcement as a basis for motion sickness is supported by extensive evidence in the medical literature. This theory is compared and contrasted with other theories. Further areas for research are suggested.


  • Re

    by Glenn W. Knox, Knox, Glenn W. M.D., J.D.

  • Shape‐Memory Stapes Prosthesis for Otosclerosis Surgery

    by Glenn W. Knox, Harlan Reitan

    Objectives:The aim of this study was to determine the efficacy of a shape‐memory alloy, Nitinol, as a component of an improved stapes prosthesis.Study Design:Prospective laboratory and clinical study to develop a Nitinol stapes prosthesis.Methods:Various diameters of Nitinol wire and temperature transition variants were analyzed with regard to ease of deformation, response to heating, and strength. The size and geometry of the closed hook was determined by measurement of 50 incus cadaver bones. Several heat sources for activating the shape memory were evaluated, including electrocautery, lasers, and warm water. Trial surgeries were then performed on human temporal bones in the laboratory. The closure characteristics of the Nitinol loop were studied. Magnetic resonance imaging (MRI) testing at 1.5 Tesla was performed to determine safety during MRI studies. Preliminary human subject trials were then instituted.Results:In all cases, a low heat condition was ample to activate the shape memory characteristics of the hook and return it to a closed position after it had been opened. Laser power was generally set well below the power needed for removing bone. The Nitinol loop closed snugly around the incus with application to the top of the hook with a low temperature laser setting. Almost any heat source was effective. MRI testing at 1.5 Tesla showed no movement of the prosthesis. Preliminary results in human subjects showed excellent air‐bone closure. The Nitinol loop holds uniform contact around the incus.Conclusions:The Nitinol piston greatly simplifies the stapedectomy procedure by taking the need for a hand operated instrument out of the surgeon's hands. Because of the nature of the Nitinol wire, it can never over‐crimp. All these characteristics make the prosthesis advantageous for otosclerosis surgery.