C. David Cooper
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
C. David Cooper has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Michelle M. Collins
Environmental Officer, Air Quality and Noise Management Bureau, Ministry of Natural Resources and Environment, Bangkok, Thailand
2 shared publicationsChristian A. Clausen
Environmental Officer, Air Quality and Noise Management Bureau, Ministry of Natural Resources and Environment, Bangkok, Thailand
1 shared publication- Christian A. Clausen Iii
Res., Biol. Sci. Branch, National Aeronautics and Space Admin., YA-D3, Kennedy Space Ctr., FL 32899
1 shared publication John D. Dietz
Environmental Officer, Air Quality and Noise Management Bureau, Ministry of Natural Resources and Environment, Bangkok, Thailand
1 shared publication- John D. Dietz
Res., Biol. Sci. Branch, National Aeronautics and Space Admin., YA-D3, Kennedy Space Ctr., FL 32899
1 shared publication Kevin R. Mackie
Department of Civil Environmental and Construction Engineering , University of Central Florida , Orlando , FL , USA
1 shared publication
Latest Publications
- 1 August 2009
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 59 (8) , 925-935
A Robust Method for Estimating Landfill Methane Emissions
Because municipal solid waste (MSW) landfills emit significant amounts of methane, a potent greenhouse gas, there is considerable interest in quantifying surficial methane emissions from l...
- 1 August 2009
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 59 (8) , 925-935
A Robust Method for Estimating Landfill Methane Emissions
Because municipal solid waste (MSW) landfills emit significant amounts of methane, a potent greenhouse gas, there is considerable interest in quantifying surficial methane emissions from l...
- 1 April 2005
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 131 (4) , 518-525
Kinetic Modeling of the Gas-Phase Oxidation of Nitric Oxide Using Hydrogen Peroxide
The use of hydrogen peroxide ( H2 O2 ) to enhance the oxidation of nitric oxide (NO) under postflame conditions in the presence or absence of sulfur dioxide (S O2 ) has been studied by means of chemical kinetic modeling and compared with pilot-scale experimental data. The experimental results were obtained from a nonisothermal reactor at atmospheric pressure with inlet temperatures in the range of 770–790 K . The CHEMKIN-II model with a kinetic mechanism from the literature was employed for this work. At the temperatures studied, H2 O2 produces OH and H O2 radicals which enhance the oxidation of NO. The OH radical also helps oxidize S O2 . The modeling results confirmed an optimum temperature of about 775 K where the NO conversion reached about 90% with an H2 O2 :NO molar ratio of 1:1. Conversion of N O2 to HN O3 was found to occur to a slight extent. Finally, the presence of S O2 was found to promote slightly the oxidation of NO to N O2 .
- 1 April 2005
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 131 (4) , 518-525
Kinetic Modeling of the Gas-Phase Oxidation of Nitric Oxide Using Hydrogen Peroxide
The use of hydrogen peroxide ( H2 O2 ) to enhance the oxidation of nitric oxide (NO) under postflame conditions in the presence or absence of sulfur dioxide (S O2 ) has been studied by means of chemical kinetic modeling and compared with pilot-scale experimental data. The experimental results were obtained from a nonisothermal reactor at atmospheric pressure with inlet temperatures in the range of 770–790 K . The CHEMKIN-II model with a kinetic mechanism from the literature was employed for this work. At the temperatures studied, H2 O2 produces OH and H O2 radicals which enhance the oxidation of NO. The OH radical also helps oxidize S O2 . The modeling results confirmed an optimum temperature of about 775 K where the NO conversion reached about 90% with an H2 O2 :NO molar ratio of 1:1. Conversion of N O2 to HN O3 was found to occur to a slight extent. Finally, the presence of S O2 was found to promote slightly the oxidation of NO to N O2 .
- 1 August 2004
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 54 (8) , 1006-1010
Mobile Source Emission Inventories—Monthly or Annual Average Inputs to MOBILE6?
In many urban areas, on-road vehicles are the biggest contributing source category of volatile organic compounds (VOCs) and nitrogen oxides (NOx). Based on a recently completed emission inventory study for three counties in central Florida, the major source by far of anthropogenic VOCs and NOx was on-road mobile sources, even though other sources (such as construction equipment, lawn and garden equipment, and various point sources) were also significant. Although there is specific guidance for conducting an ozone-season inventory for mobile sources, there is a lack of detailed guidance as to how to employ the U.S. Environmental Protection Agency's (EPA) latest mobile source emission factor program, MOBILE6, for an annual inventory. Several of the MOBILE6 inputs that significantly influence emission factors (e.g., temperature) can vary widely throughout the year, and the annual average value may not be appropriate. Rather, it may be better to utilize monthly values of these parameters. This paper investigated the sensitivity of the annual emission inventory results to using annual or monthly values of temperature, Reid Vapor Pressure of gasoline, and humidity. The results show that, for a three-county area in central Florida representing metropolitan Orlando, the annual emission inventory based on the sum of individual monthly averages is not significantly different from that calculated using one set of annual average inputs to MOBILE6.
- 1 August 2004
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 54 (8) , 1006-1010
Mobile Source Emission Inventories—Monthly or Annual Average Inputs to MOBILE6?
In many urban areas, on-road vehicles are the biggest contributing source category of volatile organic compounds (VOCs) and nitrogen oxides (NOx). Based on a recently completed emission inventory study for three counties in central Florida, the major source by far of anthropogenic VOCs and NOx was on-road mobile sources, even though other sources (such as construction equipment, lawn and garden equipment, and various point sources) were also significant. Although there is specific guidance for conducting an ozone-season inventory for mobile sources, there is a lack of detailed guidance as to how to employ the U.S. Environmental Protection Agency's (EPA) latest mobile source emission factor program, MOBILE6, for an annual inventory. Several of the MOBILE6 inputs that significantly influence emission factors (e.g., temperature) can vary widely throughout the year, and the annual average value may not be appropriate. Rather, it may be better to utilize monthly values of these parameters. This paper investigated the sensitivity of the annual emission inventory results to using annual or monthly values of temperature, Reid Vapor Pressure of gasoline, and humidity. The results show that, for a three-county area in central Florida representing metropolitan Orlando, the annual emission inventory based on the sum of individual monthly averages is not significantly different from that calculated using one set of annual average inputs to MOBILE6.
- 1 April 2001
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 127 (4) , 329-336
Pilot-Scale Evaluation of H 2 O 2 Injection to Control NO x Emissions
Nitric oxide (NO) in combustion flue gasses can be converted to higher oxidation states by the injection of aqueous solutions of hydrogen peroxide (H2O2) into the hot flue gases. The NO is oxidized to NO2, HNO2, and HNO3, which can then be removed in a wet scrubber. A pilot plant system that was designed, constructed, and operated at Kennedy Space Center confirmed previous results that H2O2 is very effective at oxidizing NO; conversions of NO above 90% were obtained at temperatures of about 500°C (930°F) using mole ratios of H2O2:NOx slightly above 1.0. The mole ratios of H2O2/NOx needed to obtain high conversions of NO were significantly lower in the pilot plant that they had been in previous laboratory studies, demonstrating that this process can be an economically feasible method for NOx control. The position of the injector and the type of atomization were very important to the efficient utilization of peroxide. When SO2 was present in the flue gas, both NO and SO2 were oxidized without increasing the...
- 1 April 2001
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 127 (4) , 329-336
Pilot-Scale Evaluation of H 2 O 2 Injection to Control NO x Emissions
Nitric oxide (NO) in combustion flue gasses can be converted to higher oxidation states by the injection of aqueous solutions of hydrogen peroxide (H2O2) into the hot flue gases. The NO is oxidized to NO2, HNO2, and HNO3, which can then be removed in a wet scrubber. A pilot plant system that was designed, constructed, and operated at Kennedy Space Center confirmed previous results that H2O2 is very effective at oxidizing NO; conversions of NO above 90% were obtained at temperatures of about 500°C (930°F) using mole ratios of H2O2:NOx slightly above 1.0. The mole ratios of H2O2/NOx needed to obtain high conversions of NO were significantly lower in the pilot plant that they had been in previous laboratory studies, demonstrating that this process can be an economically feasible method for NOx control. The position of the injector and the type of atomization were very important to the efficient utilization of peroxide. When SO2 was present in the flue gas, both NO and SO2 were oxidized without increasing the...