Georg M. Wieselthaler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Georg M. Wieselthaler has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Ernst Wolner
Department of Cardiothoracic Surgery and Ludwig Boltzmann Institute for Cardiosurgical Research, University of Vienna, Vienna, Austria
4 shared publications- Heinrich Schima
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
4 shared publications Martin Dworschak
Department of Cardiovascular Anesthesiology
2 shared publicationsMichael Grimm
Department of Cardiothoracic Surgery and LBI for Cardiosurgical Research
2 shared publicationsRichard Pacher
Department of Cardiology, Internal Medicine II, University of Vienna, Vienna, Austria
2 shared publicationsA Lassnigg
1 shared publication
Latest Publications
- 1 December 2003
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 76 (6) , 2109-2111
Special considerations on the implantation technique for the MicroMed-DeBakey ventricular assist device axial pump
- 1 December 2003
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 76 (6) , 2109-2111
Special considerations on the implantation technique for the MicroMed-DeBakey ventricular assist device axial pump
- 1 May 2001
- Published by Wiley in Artificial Organs
- Vol. 25 (5) , 331-335
First Experiences with Outpatient Care of Patients with Implanted Axial Flow Pumps
As known from patients with pulsatile ventricular assist devices (VADs), early mobilization, physical exercise, and return to normal life are essential for optimal recovery. Recently, impla...
- 1 May 2001
- Published by Wiley in Artificial Organs
- Vol. 25 (5) , 331-335
First Experiences with Outpatient Care of Patients with Implanted Axial Flow Pumps
As known from patients with pulsatile ventricular assist devices (VADs), early mobilization, physical exercise, and return to normal life are essential for optimal recovery. Recently, impla...
- 1 March 2001
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 71 (3) , S139-S143
Lessons learned from the first clinical implants of the DeBakey ventricular assist device axial pump: a single center report
- 1 March 2001
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 71 (3) , S139-S143
Lessons learned from the first clinical implants of the DeBakey ventricular assist device axial pump: a single center report
- 1 February 2000
- Published by Wolters Kluwer Health in Circulation
- Vol. 101 (4) , 356-359
First Clinical Experience With the DeBakey VAD Continuous-Axial-Flow Pump for Bridge to Transplantation
Background —A shortage of donor organs and increased numbers of deaths of patients on the waiting list for cardiac transplantation make mechanical circulatory support for a bridge to transplantation a standard clinical procedure. Continuous-flow rotary blood pumps offer exciting new perspectives. Methods and Results —Two male patients (ages 44 and 65 years) suffering from end-stage left heart failure were implanted with a DeBakey VAD axial-flow pump for use as a bridge to transplant. In the initial postoperative period, the mean pump flow was 3.9±0.5 L/min, which equals a mean cardiac index (CI) of 2.3±0.2 L · min −1 · m −2 . In both patients, the early postoperative phase was characterized by a completely nonpulsatile flow profile. However, with the recovery of heart function 8 to 12 days after implantation, increasing pulse pressures became evident, and net flow rose to 4.5±0.6 L/min, causing an increase of mean CI up to 2.7±0.2 L · min −1 · m −2 . Patients were mobilized and put through regular physical training. Hemolysis stayed in the physiological range and increased only slightly from 2.1±0.8 mg/dL before surgery to 3.3±1.8 mg/dL 6 weeks after implantation. Conclusions —The first clinical implants of the DeBakey VAD axial-flow pump have demonstrated the device to be a promising measure of bridge-to-transplant mechanical support.
- 1 February 2000
- Published by Wolters Kluwer Health in Circulation
- Vol. 101 (4) , 356-359
First Clinical Experience With the DeBakey VAD Continuous-Axial-Flow Pump for Bridge to Transplantation
Background —A shortage of donor organs and increased numbers of deaths of patients on the waiting list for cardiac transplantation make mechanical circulatory support for a bridge to transplantation a standard clinical procedure. Continuous-flow rotary blood pumps offer exciting new perspectives. Methods and Results —Two male patients (ages 44 and 65 years) suffering from end-stage left heart failure were implanted with a DeBakey VAD axial-flow pump for use as a bridge to transplant. In the initial postoperative period, the mean pump flow was 3.9±0.5 L/min, which equals a mean cardiac index (CI) of 2.3±0.2 L · min −1 · m −2 . In both patients, the early postoperative phase was characterized by a completely nonpulsatile flow profile. However, with the recovery of heart function 8 to 12 days after implantation, increasing pulse pressures became evident, and net flow rose to 4.5±0.6 L/min, causing an increase of mean CI up to 2.7±0.2 L · min −1 · m −2 . Patients were mobilized and put through regular physical training. Hemolysis stayed in the physiological range and increased only slightly from 2.1±0.8 mg/dL before surgery to 3.3±1.8 mg/dL 6 weeks after implantation. Conclusions —The first clinical implants of the DeBakey VAD axial-flow pump have demonstrated the device to be a promising measure of bridge-to-transplant mechanical support.
- 3 September 1999
- Vol. 111 (16) , 629-35
[The DeBakey VAD axial flow pump: first clinical experience with a new generation of implantable, nonpulsatile blood pumps for long-term support prior to transplantation].
Because of the high frequency of acute hemodynamic deterioration in patients awaiting cardiac transplantation, mechanical techniques of circulatory support to bridge the period until transplantation have become a standard clinical procedure. Continuous-flow rotary blood pumps offer exciting new perspectives in terms of ventricular assistance and/or as a total cardiac substitute. A DeBakey VAD axial flow pump was implanted in two male patients (aged 44 and 65 years, respectively) suffering from end-stage left heart failure. In the initial postoperative period the mean flow rate of the pump was 3.9 +/- 0.5 l/min. In both patients, the early postoperative phase was characterised by a completely non-pulsatile flow profile. Two weeks after implantation and partial recovery of the natural left ventricle, increasing pulse pressures became evident and net flow increased to 4.5 +/- 0.6 l/min. Patients were mobilised and made to under-go regular physical training. Hemolysis produced by the pump was low while free haemoglobin stayed in physiological ranges, increasing only slightly from 2.1 +/- 0.8 mg/dl preoperatively to 3.0 +/- 1.5 mg/dl ten weeks after implantation. One patient was successfully transplanted on day 74 after implantation of the DeBakey VAD while the second patient is, after 110 days of pumping, still waiting for transplantation. This first experience concerning clinical implantation of the DeBakey VAD axial flow pump showed that the device is promising as a means of providing mechanical support to bridge the period until cardiac transplantation.
- 3 September 1999
- Vol. 111 (16) , 629-35
[The DeBakey VAD axial flow pump: first clinical experience with a new generation of implantable, nonpulsatile blood pumps for long-term support prior to transplantation].
Because of the high frequency of acute hemodynamic deterioration in patients awaiting cardiac transplantation, mechanical techniques of circulatory support to bridge the period until transplantation have become a standard clinical procedure. Continuous-flow rotary blood pumps offer exciting new perspectives in terms of ventricular assistance and/or as a total cardiac substitute. A DeBakey VAD axial flow pump was implanted in two male patients (aged 44 and 65 years, respectively) suffering from end-stage left heart failure. In the initial postoperative period the mean flow rate of the pump was 3.9 +/- 0.5 l/min. In both patients, the early postoperative phase was characterised by a completely non-pulsatile flow profile. Two weeks after implantation and partial recovery of the natural left ventricle, increasing pulse pressures became evident and net flow increased to 4.5 +/- 0.6 l/min. Patients were mobilised and made to under-go regular physical training. Hemolysis produced by the pump was low while free haemoglobin stayed in physiological ranges, increasing only slightly from 2.1 +/- 0.8 mg/dl preoperatively to 3.0 +/- 1.5 mg/dl ten weeks after implantation. One patient was successfully transplanted on day 74 after implantation of the DeBakey VAD while the second patient is, after 110 days of pumping, still waiting for transplantation. This first experience concerning clinical implantation of the DeBakey VAD axial flow pump showed that the device is promising as a means of providing mechanical support to bridge the period until cardiac transplantation.