P A Payne
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
P A Payne has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
A.D. Hoffman
HD Technologies Ltd, 95–98 Atlas House, Simonsway, Manchester M22 5PP, UK
1 shared publicationM H Miran Baygi
Now in the Department of Electrical Engineering, Tarbiat Modares University, Tehran, Iran
1 shared publicationM.E.H. Amrani
Department of Instrumentation and Analytical Science, UMIST, PO Box 88, Manchester M60 1QD, UK
1 shared publicationR.M. Dowdeswell
Department of Instrumentation and Analytical Science, UMIST, PO Box 88, Manchester M60 1QD, UK
1 shared publication- Subrayal Medapati Reddy
Centre for Smart Materials, University of Lancashire, Preston, PR1 2HE, UK
1 shared publication
Latest Publications
- 24 May 2000
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 11 (6) , 776-783
Measurements of bovine albumin as a model system for the development of a hand-held ellipsometer for ophthalmic applications
Scattering ellipsometry is a measurement technique that can extract the characteristics of particles with relative ease. For some while, we have been interested in the use of scattering ellipsometry to examine the particles in the anterior chamber of the human eye. These particles are globular proteins, typically some 6 or 7 nm in diameter and measurements conducted at a wavelength of 670 nm confirm this. Particles or particle aggregates much greater in size will give rise to characteristic patterns in the ellipsometric results and analysis of these patterns could lead to a complete description of the physical properties of such particles. Examples of measurements of this nature made on latex particles are included. The results obtained from the measurements described confirm that bovine serum albumin is suitable as a calibrant for a scattering ellipsometer.
- 24 May 2000
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 11 (6) , 776-783
Measurements of bovine albumin as a model system for the development of a hand-held ellipsometer for ophthalmic applications
Scattering ellipsometry is a measurement technique that can extract the characteristics of particles with relative ease. For some while, we have been interested in the use of scattering ellipsometry to examine the particles in the anterior chamber of the human eye. These particles are globular proteins, typically some 6 or 7 nm in diameter and measurements conducted at a wavelength of 670 nm confirm this. Particles or particle aggregates much greater in size will give rise to characteristic patterns in the ellipsometric results and analysis of these patterns could lead to a complete description of the physical properties of such particles. Examples of measurements of this nature made on latex particles are included. The results obtained from the measurements described confirm that bovine serum albumin is suitable as a calibrant for a scattering ellipsometer.
- 21 September 1999
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 58 (1-3) , 536-543
Effect of unmodified and derivatised poly(vinyl chloride) overlayers on the response of an electronic nose based on conducting polymers
- 21 September 1999
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 58 (1-3) , 536-543
Effect of unmodified and derivatised poly(vinyl chloride) overlayers on the response of an electronic nose based on conducting polymers
- 7 September 1999
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 57 (1-3) , 75-82
Frequency counting interrogation techniques applied to gas sensor arrays
- 7 September 1999
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 57 (1-3) , 75-82
Frequency counting interrogation techniques applied to gas sensor arrays