Tetsuya Tateishi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tetsuya Tateishi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
T. Ushida
3 shared publications- Guoping Chen
Research Center for Macromolecules and Biomaterials, National Institute for Materials Science, Ibaraki 305-0044, Japan
2 shared publications K. Furukawa
2 shared publicationsK S Furukawa
1 shared publicationK Shirata
1 shared publicationKatsuko Furukawa
Department of Mechanical Engineering, University of Tokyo, 7-3-1, Hongo, Bunkyoku, Tokyo 113-8656, Japan
1 shared publication
Latest Publications
- 31 December 2006
- Published by Elsevier in Journal of Biomechanics
- Vol. 39, S476-476
Dynamic viscoelastic response of articular cartilage under shear and compressive loading following enzymatic treatment
- 31 December 2006
- Published by Elsevier in Journal of Biomechanics
- Vol. 39, S476-476
Dynamic viscoelastic response of articular cartilage under shear and compressive loading following enzymatic treatment
- 31 December 2006
- Published by Elsevier in Journal of Biomechanics
- Vol. 39, S328
Rapid formation model of tissue engineered aritificial vascular graft
- 31 December 2006
- Published by Elsevier in Journal of Biomechanics
- Vol. 39, S328
Rapid formation model of tissue engineered aritificial vascular graft
- 1 April 2004
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 24 (3) , 321
Editorial
- 1 April 2004
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 24 (3) , 321
Editorial
- 1 June 2002
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 5 (2) , 77-83
Biodegradable porous scaffolds for tissue engineering
- 1 June 2002
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 5 (2) , 77-83
Biodegradable porous scaffolds for tissue engineering
- 1 December 2000
- Vol. 45 (16) , 2639-45
[Tissue engineering and smart biomaterials].
- 19 July 2000
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 16,p. 1505-1506
A hybrid network of synthetic polymer mesh and collagen sponge
A novel hybrid network of synthetic polymer mesh and collagen sponge was prepared by forming collagen sponges with interconnected microporous structures in the interstices of the synthetic polymer mesh.
- 19 July 2000
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 16,p. 1505-1506
A hybrid network of synthetic polymer mesh and collagen sponge
A novel hybrid network of synthetic polymer mesh and collagen sponge was prepared by forming collagen sponges with interconnected microporous structures in the interstices of the synthetic polymer mesh.
- 1 January 1999
- Vol. 9 (4) , 209-17
Evaluation of cytotoxicity of UHMWPE wear debris.
We established a novel method to investigate the phagocytosis of ultra high molecular weight polyethylene using primary macrophage cells by an inverted cell culture method. Abundant wear debris derived from implant materials are generated in aseptic loosening and are deposited in periprosthetic tissues in which they are phagocytized by mono- and multi-nucleated macrophage like cells. Ultra-high-molecular-weight-polyethylene wear debris generated from different sources namely, from laboratory test wear machine, in vivo methods and from knee and hip simulator were mainly used in this investigation. The cytotoxicity index of the different UHMWPE particles obtained from various sources were compared with that of the PE beads and the control without particles by Alamar Blue and Neutral Red assays. The results showed that the cytotoxicity index was significantly lower for the wear debris from the in vivo experiments than that for other particles. SEM analysis were also done to understand the morphology of the wear debris and polyethylene beads and to confirm the phagocytosis process. The mean diameter of the wear debris obtained from the in vivo experiments as estimated from the imaging analysis of the SEM photographs was found to be the least. The inverted cell culture method may be regarded as one of the good methods to study the phagocytosis of UHMWPE by macrophage cells.
- 1 January 1999
- Vol. 9 (4) , 209-17
Evaluation of cytotoxicity of UHMWPE wear debris.
We established a novel method to investigate the phagocytosis of ultra high molecular weight polyethylene using primary macrophage cells by an inverted cell culture method. Abundant wear debris derived from implant materials are generated in aseptic loosening and are deposited in periprosthetic tissues in which they are phagocytized by mono- and multi-nucleated macrophage like cells. Ultra-high-molecular-weight-polyethylene wear debris generated from different sources namely, from laboratory test wear machine, in vivo methods and from knee and hip simulator were mainly used in this investigation. The cytotoxicity index of the different UHMWPE particles obtained from various sources were compared with that of the PE beads and the control without particles by Alamar Blue and Neutral Red assays. The results showed that the cytotoxicity index was significantly lower for the wear debris from the in vivo experiments than that for other particles. SEM analysis were also done to understand the morphology of the wear debris and polyethylene beads and to confirm the phagocytosis process. The mean diameter of the wear debris obtained from the in vivo experiments as estimated from the imaging analysis of the SEM photographs was found to be the least. The inverted cell culture method may be regarded as one of the good methods to study the phagocytosis of UHMWPE by macrophage cells.