Christine Preibisch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christine Preibisch has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Heinrich Lanfermann
3 shared publicationsAlexander W von Gudenberg
2 shared publicationsFriedhelm Zanella
2 shared publicationsHarald A Euler
2 shared publicationsKatrin Neumann
2 shared publicationsPeter Raab
2 shared publications
Latest Publications
- Open Access
- 18 December 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 61 (1) , 125-135
Influence of RF spoiling on the stability and accuracy of T1 mapping based on spoiled FLASH with varying flip angles
There is increasing interest in quantitative T1 mapping techniques for a variety of applications. Several methods for T1 quantification have been described. The acquisition of two spoiled gradient‐echo data sets with different flip angles allows for the calculation of T1 maps with a high spatial resolution and a relatively short experimental duration. However, the method requires complete spoiling of transverse magnetization. To achieve this goal, RF spoiling has to be applied. In this work it is investigated whether common RF spoiling techniques are sufficiently effective to allow for accurate T1 quantification. It is shown that for most phase increments the apparent T1 can deviate considerably from the true value. Correct results may be achieved with phase increments of 118.2° or 121.8°. However, for these values the method suffers from instabilities. In contrast, stable results are obtained with a phase increment of 50°. An algorithm is presented that allows for the calculation of corrected T1 maps from the apparent values. The method is tested both in phantom experiments and in vivo by acquiring whole‐brain T1 maps of the human brain. Magn Reson Med 61:125–135, 2009.
- 18 December 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 61 (1) , 125-135
Open AccessInfluence of RF spoiling on the stability and accuracy of T1 mapping based on spoiled FLASH with varying flip angles
There is increasing interest in quantitative T1 mapping techniques for a variety of applications. Several methods for T1 quantification have been described. The acquisition of two spoiled gradient‐echo data sets with different flip angles allows for the calculation of T1 maps with a high spatial resolution and a relatively short experimental duration. However, the method requires complete spoiling of transverse magnetization. To achieve this goal, RF spoiling has to be applied. In this work it is investigated whether common RF spoiling techniques are sufficiently effective to allow for accurate T1 quantification. It is shown that for most phase increments the apparent T1 can deviate considerably from the true value. Correct results may be achieved with phase increments of 118.2° or 121.8°. However, for these values the method suffers from instabilities. In contrast, stable results are obtained with a phase increment of 50°. An algorithm is presented that allows for the calculation of corrected T1 maps from the apparent values. The method is tested both in phantom experiments and in vivo by acquiring whole‐brain T1 maps of the human brain. Magn Reson Med 61:125–135, 2009.
- Open Access
- 24 September 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 60 (4) , 908-916
Exponential excitation pulses for improved water content mapping in the presence of background gradients
Several water content mapping techniques are based on the acquisition of multiple gradient echoes (GE) with different echo times (TE). However, in the presence of linear magnetic field gradients Gsusc the signal decay is no longer exponential but in the case of a rectangular slice profile weighted by a sinc function, giving rise to erroneous initial amplitudes S0 in monoexponential fitting. Generally, it can be shown that the signal decay is weighted by the time profile of the excitation pulse. Thus, for an excitation pulse with an exponential time profile, i.e., a Lorentzian slice profile, the signal decay remains exponential and exponential fitting still yields the correct amplitude S0. Multiecho GE images of a gel phantom and five human volunteers were acquired at 3 T using a sinc-shaped and an exponential excitation pulse. In addition, simulations were performed to investigate the influence of saturation effects due to distortion of the ideal Lorentzian slice profile. A considerable overestimation of S0 when using a sinc-shaped excitation pulse was observed. Errors were greatly reduced with an exponential excitation pulse. We thus propose the use of excitation pulses with exponential time profile to obtain accurate estimates for S0 from exponential fitting. Magn Reson Med 60:908–916, 2008.
- 24 September 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 60 (4) , 908-916
Open AccessExponential excitation pulses for improved water content mapping in the presence of background gradients
Several water content mapping techniques are based on the acquisition of multiple gradient echoes (GE) with different echo times (TE). However, in the presence of linear magnetic field gradients Gsusc the signal decay is no longer exponential but in the case of a rectangular slice profile weighted by a sinc function, giving rise to erroneous initial amplitudes S0 in monoexponential fitting. Generally, it can be shown that the signal decay is weighted by the time profile of the excitation pulse. Thus, for an excitation pulse with an exponential time profile, i.e., a Lorentzian slice profile, the signal decay remains exponential and exponential fitting still yields the correct amplitude S0. Multiecho GE images of a gel phantom and five human volunteers were acquired at 3 T using a sinc-shaped and an exponential excitation pulse. In addition, simulations were performed to investigate the influence of saturation effects due to distortion of the ideal Lorentzian slice profile. A considerable overestimation of S0 when using a sinc-shaped excitation pulse was observed. Errors were greatly reduced with an exponential excitation pulse. We thus propose the use of excitation pulses with exponential time profile to obtain accurate estimates for S0 from exponential fitting. Magn Reson Med 60:908–916, 2008.
- 1 October 2003
- Published by SAGE Publications in Rivista di Neuroradiologia
- Vol. 16 (5) , 1013-1014
Perfusion-Weighted Imaging Using PRESTO-SENSE
- 1 October 2003
- Published by SAGE Publications in Rivista di Neuroradiologia
- Vol. 16 (5) , 1013-1014
Perfusion-Weighted Imaging Using PRESTO-SENSE
- 1 October 2003
- Published by Elsevier in NeuroImage
- Vol. 20 (2) , 1356-1364
Evidence for compensation for stuttering by the right frontal operculum
- 1 October 2003
- Published by Elsevier in NeuroImage
- Vol. 20 (2) , 1356-1364
Evidence for compensation for stuttering by the right frontal operculum
- 1 July 2003
- Published by Elsevier in NeuroImage
- Vol. 19 (3) , 1076-1084
Event-related fMRI for the suppression of speech-associated artifacts in stuttering
- 1 July 2003
- Published by Elsevier in NeuroImage
- Vol. 19 (3) , 1076-1084
Event-related fMRI for the suppression of speech-associated artifacts in stuttering
- 1 June 2003
- Published by Elsevier in NeuroImage
- Vol. 19 (2) , 412-421
Functional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI)
- 1 June 2003
- Published by Elsevier in NeuroImage
- Vol. 19 (2) , 412-421
Functional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI)