John Saldanha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
John Saldanha has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
A. Heath
Informatics Division, National Institute for Biological Standards and Controls, South Mimms, Herts., UK
4 shared publicationsN. Lelie
CLB, Plesmanlaan 125, Amsterdam, the Netherlands
4 shared publicationsB19 Collaborative Study Group
Division of Virology, NIBSC, South Mimms, UK
1 shared publicationG. Pisani
Laboratorio di Immunologia, Istituto Superiore di Sanita, Rome, Italy
1 shared publicationK. Heermann
Division of Medical Microbiology and National Reference Laboratory for Viral Hepatitis, University of Göttingen, Göttingen, Germany
1 shared publicationM. NÜBling
Paul Ehrlich Institute, Langen, Germany
1 shared publication
Latest Publications
- 28 January 2002
- Published by Wiley in Vox Sanguinis
- Vol. 82 (1) , 24-31
Establishment of the first World Health Organization International Standard for human parvovirus B19 DNA nucleic acid amplification techniques
Background and ObjectivesA collaborative study, involving 26 laboratories from 14 countries, was carried out in order to establish a World Health Organization (WHO) International Standard for human parvovirus B19 (B19) DNA nucleic acid amplification techniques (NAT).Materials and methodsFour samples: AA, BB (which were lyophilized), CC and DD (which were liquid preparations) were analysed using several different NAT assays. The mean B19 DNA content of each sample was determined for each laboratory using an end‐point dilution method.ResultsThere was good agreement between the overall mean ‘equivalents’/ml obtained by the different assays. The mean log10‘equivalents’/ml were 5·76 for sample AA, 5·73 for sample BB, 5·82 for sample CC and 7·70 for sample DD. The differences in titre among samples AA, BB and CC were not statistically significant, but the titre of DD was significantly higher.ConclusionsDespite the range of NAT assays used in the study, it was possible to calculate the mean B19 DNA concentrations in the four preparations. Lyophilized preparation AA was established as the first International Standard for B19 DNA NAT assays and was assigned a concentration of 106international units (IU)/ml.
- 28 January 2002
- Published by Wiley in Vox Sanguinis
- Vol. 82 (1) , 24-31
Establishment of the first World Health Organization International Standard for human parvovirus B19 DNA nucleic acid amplification techniques
Background and ObjectivesA collaborative study, involving 26 laboratories from 14 countries, was carried out in order to establish a World Health Organization (WHO) International Standard for human parvovirus B19 (B19) DNA nucleic acid amplification techniques (NAT).Materials and methodsFour samples: AA, BB (which were lyophilized), CC and DD (which were liquid preparations) were analysed using several different NAT assays. The mean B19 DNA content of each sample was determined for each laboratory using an end‐point dilution method.ResultsThere was good agreement between the overall mean ‘equivalents’/ml obtained by the different assays. The mean log10‘equivalents’/ml were 5·76 for sample AA, 5·73 for sample BB, 5·82 for sample CC and 7·70 for sample DD. The differences in titre among samples AA, BB and CC were not statistically significant, but the titre of DD was significantly higher.ConclusionsDespite the range of NAT assays used in the study, it was possible to calculate the mean B19 DNA concentrations in the four preparations. Lyophilized preparation AA was established as the first International Standard for B19 DNA NAT assays and was assigned a concentration of 106international units (IU)/ml.
- 10 January 2001
- Published by Elsevier in Journal of Clinical Virology
- Vol. 20 (1-2) , 7-13
Validation and standardisation of nucleic acid amplification technology (NAT) assays for the detection of viral contamination of blood and blood products
- 10 January 2001
- Published by Elsevier in Journal of Clinical Virology
- Vol. 20 (1-2) , 7-13
Validation and standardisation of nucleic acid amplification technology (NAT) assays for the detection of viral contamination of blood and blood products
- 1 January 2001
- Published by Wiley in Vox Sanguinis
- Vol. 80 (1) , 63-71
An international collaborative study to establish a World Health Organization international standard for hepatitis B virus DNA nucleic acid amplification techniques
Background and objectives: Twenty‐two laboratories from nine countries participated in an international collaborative study to establish a World Health Organization (WHO) international standard for hepatitis B virus (HBV) DNA nucleic acid amplification techniques (NAT).Materials and methods: Three samples, AA, BB (both of which were lyophilized) and CC (which was a liquid preparation), were analysed using several different NAT assays. The mean HBV DNA content of each sample was determined from the study.Results: Despite the range of assays (commercial and in‐house) used by participants, there was good agreement among the overall mean ‘equivalents’/ml obtained by the different assays, except for one laboratory (laboratory 4). The variation in estimates of log10‘equivalents’/ml was 1·75–1·25 for the three samples if results from laboratory 4 were excluded. The mean log10‘equivalents’/ml for all laboratories were 6·42 for sample AA, 6·30 for sample BB and 5·03 for sample CC (exclusion of results from laboratory 4 made little difference). The difference in titres between the two lyophilized samples (AA and BB) was not statistically significant but the titre of the frozen sample (CC) was significantly lower. Material AA (code 97/746) was accepted as the first WHO international standard for HBV DNA NAT assays and assigned a potency of 106international units (IU)/ml.Conclusions: The titres (genome equivalents/ml) of three HBV preparations were determined by several laboratories using different NAT assays. This study enabled the establishment of an international standard, 97/746, for HBV DNA NAT assays.
- 1 January 2001
- Published by Wiley in Vox Sanguinis
- Vol. 80 (1) , 63-71
An international collaborative study to establish a World Health Organization international standard for hepatitis B virus DNA nucleic acid amplification techniques
Background and objectives: Twenty‐two laboratories from nine countries participated in an international collaborative study to establish a World Health Organization (WHO) international standard for hepatitis B virus (HBV) DNA nucleic acid amplification techniques (NAT).Materials and methods: Three samples, AA, BB (both of which were lyophilized) and CC (which was a liquid preparation), were analysed using several different NAT assays. The mean HBV DNA content of each sample was determined from the study.Results: Despite the range of assays (commercial and in‐house) used by participants, there was good agreement among the overall mean ‘equivalents’/ml obtained by the different assays, except for one laboratory (laboratory 4). The variation in estimates of log10‘equivalents’/ml was 1·75–1·25 for the three samples if results from laboratory 4 were excluded. The mean log10‘equivalents’/ml for all laboratories were 6·42 for sample AA, 6·30 for sample BB and 5·03 for sample CC (exclusion of results from laboratory 4 made little difference). The difference in titres between the two lyophilized samples (AA and BB) was not statistically significant but the titre of the frozen sample (CC) was significantly lower. Material AA (code 97/746) was accepted as the first WHO international standard for HBV DNA NAT assays and assigned a potency of 106international units (IU)/ml.Conclusions: The titres (genome equivalents/ml) of three HBV preparations were determined by several laboratories using different NAT assays. This study enabled the establishment of an international standard, 97/746, for HBV DNA NAT assays.
- 1 January 2000
- Published by Wiley in Vox Sanguinis
- Vol. 78 (4) , 217-224
Calibration of HCV Working Reagents for NAT Assays against the HCV International Standard
Five HCV RNA reference reagents, the Paul Ehrlich Institut (PEI) reference 75, the National Institute for Biological Standards and Control (NIBSC) reagent 96/586, the Central Laboratory of the Netherlands Red Cross Blood Transfusion Service (CLB) Pelispy HCV RNA run control S2001, the Istituto Superiore di Sanità (ISS) reagent 0498 and the CBER panel member No. 1, were calibrated against the WHO International Standard, 96/790. The reference materials were calibrated in a collaborative study organised by NIBSC. Nineteen laboratories, using a range of qualitative and quantitative assays returned results. The concentrations of the reagents were: 25,000 IU/ml for the PEI material, 710 IU/ml for the NIBSC material 96/586, 1,000 IU/ml for the CLB material, 1,700 IU/ml for the ISS material 0498 and 250 IU/ml for the CBER panel member No. 1. The calibration of these five reference reagents for HCV RNA nucleic acid amplification technology (NAT) assays enables them to be used for standardisation and validation of assays. Such calibrants are essential for meeting the requirements of the European Medicinal Evaluation Agency (EMEA) for the testing of plasma pools and donations for HCV RNA for the release of blood products and the PEI requirements for the release testing of erythrocyte and thrombocyte concentrates.
- 1 January 2000
- Published by Wiley in Vox Sanguinis
- Vol. 78 (4) , 217-224
Calibration of HCV Working Reagents for NAT Assays against the HCV International Standard
Five HCV RNA reference reagents, the Paul Ehrlich Institut (PEI) reference 75, the National Institute for Biological Standards and Control (NIBSC) reagent 96/586, the Central Laboratory of the Netherlands Red Cross Blood Transfusion Service (CLB) Pelispy HCV RNA run control S2001, the Istituto Superiore di Sanità (ISS) reagent 0498 and the CBER panel member No. 1, were calibrated against the WHO International Standard, 96/790. The reference materials were calibrated in a collaborative study organised by NIBSC. Nineteen laboratories, using a range of qualitative and quantitative assays returned results. The concentrations of the reagents were: 25,000 IU/ml for the PEI material, 710 IU/ml for the NIBSC material 96/586, 1,000 IU/ml for the CLB material, 1,700 IU/ml for the ISS material 0498 and 250 IU/ml for the CBER panel member No. 1. The calibration of these five reference reagents for HCV RNA nucleic acid amplification technology (NAT) assays enables them to be used for standardisation and validation of assays. Such calibrants are essential for meeting the requirements of the European Medicinal Evaluation Agency (EMEA) for the testing of plasma pools and donations for HCV RNA for the release of blood products and the PEI requirements for the release testing of erythrocyte and thrombocyte concentrates.
- 1 January 1999
- Published by Wiley in Vox Sanguinis
- Vol. 76 (3) , 163-165
Sensitivity of PCR Assays for the Determination of Hepatitis A Virus RNA in Plasma Pools
A collaborative study was organised to establish a hepatitis A virus (HAV) RNA standard for genomic amplification assays (GAT). A panel of 10 samples consisting of a 10-fold serial dilution of wild-type HAV diluted in HAV-negative cryosupernatant and samples of the diluent were sent to 14 laboratories in duplicate for testing for HAV RNA by the polymerase chain reaction. Data returned by 12 laboratories indicated that the sensitivities of the assays performed by different laboratories were fairly close: there was a 100-fold difference in sensitivity between the majority of laboratories. Only one laboratory reported false-positive results. A 10-5 dilution of the virus in cryosupernatant could be an appropriate working reagent for GAT assays for HAV RNA in plasma pools.
- 1 January 1999
- Published by Wiley in Vox Sanguinis
- Vol. 76 (3) , 163-165
Sensitivity of PCR Assays for the Determination of Hepatitis A Virus RNA in Plasma Pools
A collaborative study was organised to establish a hepatitis A virus (HAV) RNA standard for genomic amplification assays (GAT). A panel of 10 samples consisting of a 10-fold serial dilution of wild-type HAV diluted in HAV-negative cryosupernatant and samples of the diluent were sent to 14 laboratories in duplicate for testing for HAV RNA by the polymerase chain reaction. Data returned by 12 laboratories indicated that the sensitivities of the assays performed by different laboratories were fairly close: there was a 100-fold difference in sensitivity between the majority of laboratories. Only one laboratory reported false-positive results. A 10-5 dilution of the virus in cryosupernatant could be an appropriate working reagent for GAT assays for HAV RNA in plasma pools.
- 1 January 1999
- Published by Wiley in Vox Sanguinis
- Vol. 76 (3) , 149-158
Establishment of the First International Standard for Nucleic Acid Amplification Technology (NAT) Assays for HCV RNA
The aims of this study were the establishment of a WHO International standard for HCV RNA for nucleic acid amplification technology (NAT) assays and the determination of the HCV RNA content of the candidate standard. Twenty-two laboratories evaluated three candidate materials (two lyophilised, AA and BB, which were derived from the same source and one a liquid preparation, CC). All samples were HCV genotype 1 with a concentration of approximately 10(5) genome equivalents/ml. The methods used included the Roche Amplicor assay (version 1), Chiron Quantiplex (bDNA) assay, Organon Teknika NASBA assay, Transcription Mediated assay and various in-house assays, using single or nested primers. There was reasonable agreement between the overall mean NAT detectable units/ml obtained by the different assays except for some of the in-house assays using single primers which gave substantially lower estimates. These titres were 5.0 log10 for samples AA and BB and 4.6 log10 for sample CC. Sample AA was accepted as the candidate standard and assigned a titre of 10(5) international units (IU)/ml. The International Standard consists of a batch of vials each containing 50,000 IU/vial. Preliminary studies indicated that the material is stable at +4 degrees C and +20 degrees C for up to 200 days.
- 1 January 1999
- Published by Wiley in Vox Sanguinis
- Vol. 76 (3) , 149-158
Establishment of the First International Standard for Nucleic Acid Amplification Technology (NAT) Assays for HCV RNA
The aims of this study were the establishment of a WHO International standard for HCV RNA for nucleic acid amplification technology (NAT) assays and the determination of the HCV RNA content of the candidate standard. Twenty-two laboratories evaluated three candidate materials (two lyophilised, AA and BB, which were derived from the same source and one a liquid preparation, CC). All samples were HCV genotype 1 with a concentration of approximately 10(5) genome equivalents/ml. The methods used included the Roche Amplicor assay (version 1), Chiron Quantiplex (bDNA) assay, Organon Teknika NASBA assay, Transcription Mediated assay and various in-house assays, using single or nested primers. There was reasonable agreement between the overall mean NAT detectable units/ml obtained by the different assays except for some of the in-house assays using single primers which gave substantially lower estimates. These titres were 5.0 log10 for samples AA and BB and 4.6 log10 for sample CC. Sample AA was accepted as the candidate standard and assigned a titre of 10(5) international units (IU)/ml. The International Standard consists of a batch of vials each containing 50,000 IU/vial. Preliminary studies indicated that the material is stable at +4 degrees C and +20 degrees C for up to 200 days.
- 1 November 1997
- Published by Wiley in Vox Sanguinis
- Vol. 73 (4) , 207-211
Collaborative Study to Assess the Suitability of a Proposed Working Reagent for Human Parvovirus B19 DNA Detection in Plasma Pools by Gene Amplification Techniques
- 1 November 1997
- Published by Wiley in Vox Sanguinis
- Vol. 73 (4) , 207-211
Collaborative Study to Assess the Suitability of a Proposed Working Reagent for Human Parvovirus B19 DNA Detection in Plasma Pools by Gene Amplification Techniques