SLStephen R. Lee

Stephen R. Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stephen R. Lee has a total of 28 co-authors. Here are the top co-authors by number of shared publications:

  • J. Peterson

    Ortho Clinical Diagnostics, Raritan, NJ, USA

    3 shared publications
  • G. Green

    Ortho Clinical Diagnostics, Raritan, NJ, USA

    2 shared publications
  • A. Polito

    From the Blood Centers of the Pacific—Irwin Center; and the University of California, San Francisco, California; Ortho Clinical Diagnostics, Raritan, New Jersey; American Red Cross; and Westat, Inc., Rockville, Maryland; PraxSys BioSystems, Inc., San Ramon, California; and Chiron Corporation, Emeryville, California

    1 shared publication
  • Allan G. Redeker

    1 shared publication
  • B. Caldwell

    Ortho Clinical Diagnostics, Raritan, N.J., USA

    1 shared publication
  • Boontar Valinluck

    1 shared publication

Latest Publications

  • Efficacy of a hepatitis C virus core antigen enzyme‐linked immunosorbent assay for the identification of ‘window‐phase’ blood donations

    by S. R. Lee, J. Peterson, P. Niven, C. Bahl, E. Page, R. DeLeys, D. Giordano‐Schmidt, D. Baggett, G. Green

    Background and Objectives Recent studies have suggested that potentially infectious donations provided during the antibody‐negative ‘window’ phase of hepatitis C virus (HCV) infection may be identified by testing for viral RNA or HCV core protein. We therefore evaluated the performance of an HCV antigen enzyme‐linked immunosorbent assay (ELISA) for identification of window‐phase donations and for prospective screening of blood donors. Materials and Methods One‐hundred and twenty‐eight archived plasma donations containing HCV RNA, but lacking antibody to HCV (anti‐HCV), were tested by using the HCV antigen ELISA, together with 9951 freshly collected serum and plasma specimens from blood donors. Results HCV core antigen was detected in 94% (120/128) of window‐phase plasma donations. Overall specificity in freshly collected blood donor specimens was 99·74%. Two putative window‐phase donations containing HCV core protein and viral RNA were identified from paid plasma donors by prospective testing with the HCV antigen ELISA. Conclusion These results indicate that an HCV antigen ELISA can identify almost all (94%) of viraemic donations given during the seronegative window phase of infection. The performance of the HCV antigen ELISA appears to be suitable for large‐scale screening of blood donations.


  • Performance of second‐ and third‐generationRIBAs for confirmation of third‐generationHCV EIA‐reactive blood donations

    by L.H. Tobler, S.R. Lee, S.L. Stramer, J. Peterson, R. Kochesky, K. Watanabe, S. Quan, A. Polito, M.P. Busch, for the Retrovirus Epidemiology Donor Study

    BACKGROUND: Licensure of an enhanced HCV screening assay (HCV 3.0 EIA) without concurrent licensure of a complementary supplemental assay (i.e., RIBA HCV 3.0 strip immunoblot assay [RIBA‐3]) decoupled screening and supplemental testing. In March 1998, the FDA Center for Biologics Evaluation and Research (CBER) recommended the use of RIBA‐3 on RIBA HCV 2.0 strip immunoblot assay (RIBA‐2)‐indeterminate units screened with HCV EIA 3.0. STUDY DESIGN AND METHODS: The sensitivity of RIBA‐2 and RIBA‐3 was compared in tests on HCV 3.0 EIA‐repeatably reactive (RR) units identified immediately after the implementation of HCV 3.0 EIA screening. Two protocols were evaluated: parallel testing of HCV 3.0 EIA‐RR units by RIBA‐2 and RIBA‐3 and reflex testing of HCV 3.0 EIA‐RR and RIBA‐3‐confirmed‐positive units by RIBA‐2. All specimens with discordant RIBA‐2 and RIBA‐3 results and a representative sampling with concordant RIBA results were tested by PCR. RESULTS: In the parallel testing protocol, 99,777 donations were screened, with 245 HCV 3.0 EIA‐RR specimens included in the study. Of 166 RIBA‐2‐positive samples, 165 tested positive in RIBA‐3 (1 sample reacted to the control superoxide dismutase antigen in RIBA‐3). Thirty‐two (74%) of 43 RIBA‐2‐indeterminate specimens and 4 (11%) of 36 RIBA‐2‐negative specimens tested positive in RIBA‐3. HCV RNA was identified in 5 (16%) of 32 RIBA‐2‐indeterminate/RIBA‐3‐positive donations, as well as in 26 (70%) of 37 concordant RIBA‐2/RIBA‐3‐positive donations. In the reflex testing protocol, 292,459 donations were screened, with 709 HCV 3.0 EIA‐RR specimens included in the study. RIBA‐3 testing yielded 517 (73%) positive specimens, of which 50 (9.7%) tested indeterminate and 15 (2.9%) tested negative in RIBA‐2. Among the RIBA‐discordant specimens, 10 (20%) RIBA‐2‐indeterminate specimens and 1 (7%) RIBA‐2‐negative specimens tested positive in PCR; in comparison, 60 (77%) of 78 concordant RIBA‐2/RIBA‐3‐positive units tested positive in PCR. CONCLUSIONS: RIBA‐3 is significantly more sensitive than RIBA‐2 in testing of HCV 3.0 EIA‐screened donations. During the review process of this manuscript, the FDA licensed the RIBA‐3 test.


  • Detection of Hepatitis C Core Antigen in the Antibody Negative ‘Window’ Phase of Hepatitis C Infection

    by J. Peterson, G. Green, K. Iida, B. Caldwell, P. Kerrison, S. Bernich, K. Aoyagi, S.R. Lee

    Background and Objectives: Despite improvements in assays for anti–HCV, there remains a significant delay before the appearance of antibodies following infection, during which, circulating viral RNA is present. We have evaluated a prototype assay for the serological detection of hepatitis C virus (HCV) core antigen with specimens derived from the early phase of HCV infection. Materials and Methods: Serial specimens from 24 individuals undergoing HCV seroconversion were tested for the presence of anti–HCV, HCV RNA and HCV core antigen. Results: HCV antigen was detected at the same time as HCV RNA in 83% (20/24) cases. The mean time to the first detection of HCV antigen was approximately 1 day later than HCV RNA. Overall, 87% of HCV–RNA–positive specimens contained detectable HCV core antigen. Conclusion: These results indicate that HCV core antigen can be identified by routine serological ELISA in specimens from the early antibody–negative phase of HCV infection. A test for HCV core antigen may be a useful test for identifying window phase blood donations from antibody negative donors infected with HCV.


  • Open Access

    Marked Improvement in Sensitivity of Second-Generation Tests for Acute Hepatitis C Virus Infection

    by Tse-Ling Fong, Boontar Valinluck, Sugantha Govindarajan, Noel Rolon, Stephen R. Lee, Eileen Page, James Darner, Allan G. Redeker

    Tse-Ling Fong, Boontar Valinluck, Sugantha Govindarajan, Noel Rolon, Stephen R. Lee, Eileen Page, James Darner, Allan G. Redeker; Marked Improvement in Sensitiv