Thomas Menzel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas Menzel has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Eckhard Mayer
3 shared publicationsJuergen Meyer
3 shared publicationsSusanne Mohr-Kahaly
3 shared publicationsThorsten Kramm
3 shared publicationsE. Mayer
Dept. of Heart Surgery, University of Mainz Medical Center, Mainz, Germany
2 shared publicationsJ Meyer
2 shared publications
Latest Publications
- Open Access
- 1 December 2003
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 4 (suppl_1) , S145
258 Right heart wall motion and volume analysis in severe chronic pulmonary hypertension using realtime three dimensional echocardiography compared to MR imaging
R. S. Von Bardeleben, T. Kramm, R. Schnabel, K. Oberholzer, T. Menzel, E. Mayer, S. Mohr-Kahaly; 258 Right heart wall motion and volume analysis in severe chro
- 1 December 2003
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 4 (suppl_1) , S145
Open Access258 Right heart wall motion and volume analysis in severe chronic pulmonary hypertension using realtime three dimensional echocardiography compared to MR imaging
R. S. Von Bardeleben, T. Kramm, R. Schnabel, K. Oberholzer, T. Menzel, E. Mayer, S. Mohr-Kahaly; 258 Right heart wall motion and volume analysis in severe chro
- 1 March 2002
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 73 (3) , 756-761
Improvement of tricuspid regurgitation after pulmonary thromboendarterectomy
- 1 March 2002
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 73 (3) , 756-761
Improvement of tricuspid regurgitation after pulmonary thromboendarterectomy
- 1 March 2002
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 73 (3) , 762-766
Assessment of cardiac performance using Tei indices in patients undergoing pulmonary thromboendarterectomy
- 1 March 2002
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 73 (3) , 762-766
Assessment of cardiac performance using Tei indices in patients undergoing pulmonary thromboendarterectomy
- Open Access
- 1 March 2002
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 3 (1) , 67-72
Quantitative Assessment of Right Ventricular Volumes in Severe Chronic Thromboembolic Pulmonary Hypertension using Transthoracic Three-dimensional Echocardiography: Changes due to Pulmonary Thromboendarterectomy
Aims: Evaluation of a three-dimensional reconstruction method to show the changes of right ventricular volume and systolic function when patients und
- 1 March 2002
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 3 (1) , 67-72
Open AccessQuantitative Assessment of Right Ventricular Volumes in Severe Chronic Thromboembolic Pulmonary Hypertension using Transthoracic Three-dimensional Echocardiography: Changes due to Pulmonary Thromboendarterectomy
Aims: Evaluation of a three-dimensional reconstruction method to show the changes of right ventricular volume and systolic function when patients und
- 1 August 1996
- Vol. 85 (8) , 588-95
[Prospective study of subjective stress caused by dobutamine stress echocardiography--effect on diagnostic accuracy].
We used a standardized questionnaire to assess physical and mental distress caused by dobutamine stress echocardiography (DSE). The examination was performed according to a standardized protocol (5-40 micrograms/kg/min including atropine). 91 patients (pts), 68 men (62 +/- 9 years), 23 women (65 +/- 7 years) were asked to quantify the severity of the following symptoms: palpitations, anxiety, headache, nausea, discomfort of left lateral position, angina pectoris and dyspnea. Numbers on a rating scale from 1-10 defined the degree of distress. Absence of a symptom equalled mark, 1, slight expression marks 2-4. Moderate expression was defined by marks 5-7 and very strong expression by marks 8-10. 86% of pts felt affected by one or more symptoms to a slight to moderate extent (mark 4 +/- 2.17). Palpitations were felt by 85% of the pts (mark 6 +/- 2.83), anxiety by 42% (mark 3 +/- 2.5), headache by 50% (3 +/- 2.54), nausea by 20% (2 +/- 1.72), angina pectoris by 42% (3 +/- 2.5), dyspnea by 30% (2 +/- 2.42) and discomfort of left lateral recumbent position by 43% (mark 3 +/- 2.59). 43 pts underwent coronary angiography. The negative predictive value of DSE to identify pts without a coronary artery stenosis extending a 50% diameter reduction was 85% for the 16 pts who reached their individual submaximal heart rate compared to 60% for those 27 pts who did not reach it. Unspecific symptoms led to test termination in these pts. The positive predictive values were comparable (89 and 94%). DSE causes physical and mental distress. If symptoms lead to test termination before age corrected submaximal heart rate is reached, normal wall motion does not exclude significant coronary artery disease.
- 1 August 1996
- Vol. 85 (8) , 588-95
[Prospective study of subjective stress caused by dobutamine stress echocardiography--effect on diagnostic accuracy].
We used a standardized questionnaire to assess physical and mental distress caused by dobutamine stress echocardiography (DSE). The examination was performed according to a standardized protocol (5-40 micrograms/kg/min including atropine). 91 patients (pts), 68 men (62 +/- 9 years), 23 women (65 +/- 7 years) were asked to quantify the severity of the following symptoms: palpitations, anxiety, headache, nausea, discomfort of left lateral position, angina pectoris and dyspnea. Numbers on a rating scale from 1-10 defined the degree of distress. Absence of a symptom equalled mark, 1, slight expression marks 2-4. Moderate expression was defined by marks 5-7 and very strong expression by marks 8-10. 86% of pts felt affected by one or more symptoms to a slight to moderate extent (mark 4 +/- 2.17). Palpitations were felt by 85% of the pts (mark 6 +/- 2.83), anxiety by 42% (mark 3 +/- 2.5), headache by 50% (3 +/- 2.54), nausea by 20% (2 +/- 1.72), angina pectoris by 42% (3 +/- 2.5), dyspnea by 30% (2 +/- 2.42) and discomfort of left lateral recumbent position by 43% (mark 3 +/- 2.59). 43 pts underwent coronary angiography. The negative predictive value of DSE to identify pts without a coronary artery stenosis extending a 50% diameter reduction was 85% for the 16 pts who reached their individual submaximal heart rate compared to 60% for those 27 pts who did not reach it. Unspecific symptoms led to test termination in these pts. The positive predictive values were comparable (89 and 94%). DSE causes physical and mental distress. If symptoms lead to test termination before age corrected submaximal heart rate is reached, normal wall motion does not exclude significant coronary artery disease.
- 1 February 1996
- Vol. 46 (2) , 228-34
[Determination of systolic left ventricular time interval using the doppler technique. Analysis of aortic flow spectrum with transthoracic echocardiography].
In 10 healthy volunteers (age 21-28 years; mean age 24.8 years +/- 1.9 years) systolic left ventricular time intervals (STI) were determined by analysis of aortic Doppler flow pattern. This method was compared with conventional calculation of STI, using electrocardiogram, carotid pulse curve and phonocardiography, which were registered in synchronicity to the Doppler examination. Both, CW- and PW Doppler echocardiography constantly showed slightly lower values than the conventional method. This referred to basic measurements as well as to measurements after the application of isoprenaline and quinidine. The PW Doppler method underestimated the conventional method concerning the electromechanic systole (QS2) by on average 3.98%, the left ventricular ejection period (LVET) by on average 2.24% and the pre-ejection period (PEP) by on average 7.3%. Using CW-Doppler-method, QS2 was on average 5.31% and LVET was on average 6.67% smaller than the values determined by conventional method, whereas PEP was overestimated by on average 1.69%. The study documented that positive and negative inotropic pharmacological effects were measured reliably by the Doppler-echocardiographic method. Isoprenaline caused a significant shortening of frequency corrected QS2 (QS2c) from -55 +/- 17 to -85 +/- 20 ms (p < 0.05) using the PW-Doppler method; frequency corrected PEP (PEPc) was shortened from -40 +/- 14 to -67 +/- 14 ms (p < 0.05). The CW Doppler method also showed a statistically significant reduction of QS2c (from -64 +/- 18 to -89 +/- 25 ms; p < 0.05) and PEPc (from -37 +/- 16 to -64 +/- 12; p < 0.05). Likewise, the conventional method demonstrated statistically significant shortening of QS2c and PEPc after application of isoprenaline. LVETc did not change in a state of positive inotropy, no matter which method was used for determination. The negative inotropic effect of quinidine, measured by PW-Doppler, resulted in a prolongation of QS2c from -55 +/- 16 to -32 +/- 24 ms (p < 0.05) and of LVETc from -20 +/- 11 to +6 +/- 17 ms (p < 0.05). Using CW Doppler method, quinidine led to a lengthening of QS2c from -63 +/- 16 to -42 +/- 22 (p < 0.05) and of LVETc from -33 +/- 11 to -12 +/- 8 ms (p < 0.05). The conventional method also demonstrated a statistically significant increase of QS2c and LVETc. None of the 3 methods in question showed a statistically significant alteration of PEPc in the negative inotropic state. Doppler-echocardiographic analysis of aortic flow pattern constitutes a new method for the measuring of systolic time intervals. Basic values as well as changes due to positive or negative inotropic effects are reliably determined, in comparison with conventional methods the measurements are slightly lower.
- 1 February 1996
- Vol. 46 (2) , 228-34
[Determination of systolic left ventricular time interval using the doppler technique. Analysis of aortic flow spectrum with transthoracic echocardiography].
In 10 healthy volunteers (age 21-28 years; mean age 24.8 years +/- 1.9 years) systolic left ventricular time intervals (STI) were determined by analysis of aortic Doppler flow pattern. This method was compared with conventional calculation of STI, using electrocardiogram, carotid pulse curve and phonocardiography, which were registered in synchronicity to the Doppler examination. Both, CW- and PW Doppler echocardiography constantly showed slightly lower values than the conventional method. This referred to basic measurements as well as to measurements after the application of isoprenaline and quinidine. The PW Doppler method underestimated the conventional method concerning the electromechanic systole (QS2) by on average 3.98%, the left ventricular ejection period (LVET) by on average 2.24% and the pre-ejection period (PEP) by on average 7.3%. Using CW-Doppler-method, QS2 was on average 5.31% and LVET was on average 6.67% smaller than the values determined by conventional method, whereas PEP was overestimated by on average 1.69%. The study documented that positive and negative inotropic pharmacological effects were measured reliably by the Doppler-echocardiographic method. Isoprenaline caused a significant shortening of frequency corrected QS2 (QS2c) from -55 +/- 17 to -85 +/- 20 ms (p < 0.05) using the PW-Doppler method; frequency corrected PEP (PEPc) was shortened from -40 +/- 14 to -67 +/- 14 ms (p < 0.05). The CW Doppler method also showed a statistically significant reduction of QS2c (from -64 +/- 18 to -89 +/- 25 ms; p < 0.05) and PEPc (from -37 +/- 16 to -64 +/- 12; p < 0.05). Likewise, the conventional method demonstrated statistically significant shortening of QS2c and PEPc after application of isoprenaline. LVETc did not change in a state of positive inotropy, no matter which method was used for determination. The negative inotropic effect of quinidine, measured by PW-Doppler, resulted in a prolongation of QS2c from -55 +/- 16 to -32 +/- 24 ms (p < 0.05) and of LVETc from -20 +/- 11 to +6 +/- 17 ms (p < 0.05). Using CW Doppler method, quinidine led to a lengthening of QS2c from -63 +/- 16 to -42 +/- 22 (p < 0.05) and of LVETc from -33 +/- 11 to -12 +/- 8 ms (p < 0.05). The conventional method also demonstrated a statistically significant increase of QS2c and LVETc. None of the 3 methods in question showed a statistically significant alteration of PEPc in the negative inotropic state. Doppler-echocardiographic analysis of aortic flow pattern constitutes a new method for the measuring of systolic time intervals. Basic values as well as changes due to positive or negative inotropic effects are reliably determined, in comparison with conventional methods the measurements are slightly lower.