L. Berdondini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
L. Berdondini has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Sergio Martinoia
Department of Informatics, Bioengineering, Robotics, and Systems Engineering (DIBRIS), University of Genova, Genova, Italy
3 shared publications - A. Garenne
INSERM EPI-9914, Rue Camille Saint-Saëns 1, FR-33077 Bordeaux, France
2 shared publications - Kilian Imfeld
Institute of Microtechnology (IMT), Université de Neuchâtel, Jaquet-Droz 1, 2007 Neuchâtel, Switzerland
2 shared publications M. Koudelka-Hep
Sensors, Actuators and Microsystems Laboratory, Institute of Microtechnology, University of Neuchâtel, Rue Jaquet-Droz 1, CH-2007 Neuchâtel, Switzerland
2 shared publications- M. Koudelka-Hep
Sensors, Actuators and Microsystems, Laboratory of the Institute of Microtechnology, University of Neuchâtel, Rue Jaquet-Droz 1, CH-2003 Neuchâtel, Switzerland
2 shared publications N.F. de Rooij
Sensors, Actuators and Microsystems Laboratory, Institute of Microtechnology, University of Neuchâtel, Rue Jaquet-Droz 1, CH-2007 Neuchâtel, Switzerland
2 shared publications
Latest Publications
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 6085-6088
High-resolution MEA platform for in-vitro electrogenic cell networks imaging
A platform based on an active-pixel-sensor electrode array (APS-MEA) for high-resolution imaging of in-vitro electrogenic cell cultures is presented, characterized and validated under culture conditions. The system enables full frame acquisition at 8 kHz from 4096 microelectrodes integrated with separations of 21 mum and zoomed area acquisition with temporal resolutions down to 8 mus. This bi-modal acquisition feature opens new perspectives in particular for neuronal activity analysis and for the correlation of micro-scale and macro-scale behaviors. The low-noise performances of the integrated amplifier (11 muVRMS) combined with a hardware implementation reflecting image-/video-concepts enable high-resolution acquisitions with real-time processing capabilities adapted to the handling of the large amount of acquired data.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 6085-6088
High-resolution MEA platform for in-vitro electrogenic cell networks imaging
A platform based on an active-pixel-sensor electrode array (APS-MEA) for high-resolution imaging of in-vitro electrogenic cell cultures is presented, characterized and validated under culture conditions. The system enables full frame acquisition at 8 kHz from 4096 microelectrodes integrated with separations of 21 mum and zoomed area acquisition with temporal resolutions down to 8 mus. This bi-modal acquisition feature opens new perspectives in particular for neuronal activity analysis and for the correlation of micro-scale and macro-scale behaviors. The low-noise performances of the integrated amplifier (11 muVRMS) combined with a hardware implementation reflecting image-/video-concepts enable high-resolution acquisitions with real-time processing capabilities adapted to the handling of the large amount of acquired data.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19483546,p. 225-228
Motivations and APS-based solution for high-resolution extracellular recording from in-vitro neuronal networks
Mapping neuronal networks activity of in-vitro cell cultures with microelectrode array (MEA) based systems, providing a spatial resolution down to cellular/sub-cellular levels and an adequate temporal resolution for resolving action potential propagation in both micro- and macro-circuitry, can not be achieved with the conventional implementation. New technological approaches for managing high-density electrode arrays, i.e. at least separations down to cellular dimensions, and for handling a large amount of channels, i.e. several thousands, are required. After evaluating the spatiotemporal resolutions requirements with custom designed MEAs on neuronal culture preparations, an approach based on image/video concepts reflected by both hardware and data management implementations is presented here. Our platform enables the high-resolution acquisition (full frame or zoomed), from arrays of 4096 microelectrodes integrated with separations of 21 mum and with temporal resolutions down to 10 mus, opening thus new perspectives for neuronal networks activity analysis.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19483546,p. 225-228
Motivations and APS-based solution for high-resolution extracellular recording from in-vitro neuronal networks
Mapping neuronal networks activity of in-vitro cell cultures with microelectrode array (MEA) based systems, providing a spatial resolution down to cellular/sub-cellular levels and an adequate temporal resolution for resolving action potential propagation in both micro- and macro-circuitry, can not be achieved with the conventional implementation. New technological approaches for managing high-density electrode arrays, i.e. at least separations down to cellular dimensions, and for handling a large amount of channels, i.e. several thousands, are required. After evaluating the spatiotemporal resolutions requirements with custom designed MEAs on neuronal culture preparations, an approach based on image/video concepts reflected by both hardware and data management implementations is presented here. Our platform enables the high-resolution acquisition (full frame or zoomed), from arrays of 4096 microelectrodes integrated with separations of 21 mum and with temporal resolutions down to 10 mus, opening thus new perspectives for neuronal networks activity analysis.
- 1 July 2005
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 21 (1) , 167-174
High-density electrode array for imaging in vitro electrophysiological activity
- 1 July 2005
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 21 (1) , 167-174
High-density electrode array for imaging in vitro electrophysiological activity
- 28 June 2005
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 114 (1) , 530-541
A microelectrode array (MEA) integrated with clustering structures for investigating in vitro neurodynamics in confined interconnected sub-populations of neurons
- 28 June 2005
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 114 (1) , 530-541
A microelectrode array (MEA) integrated with clustering structures for investigating in vitro neurodynamics in confined interconnected sub-populations of neurons