Hilmar Franke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hilmar Franke has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
A. Draude
Institute of Physics, University of Duisburg, Duisburg, Germany
1 shared publicationG. Hanisch
Laboratorium für Angewandte Physik, Gerhard–Mercator–Universität Duisburg, Lotharstraße 1-21, D-47048 Duisburg, Germany
1 shared publicationN. Reinke
Institute of Physics, University of Duisburg, Duisburg, Germany
1 shared publicationR.A. Lessard
COPL, Department de Physique, Univ. Laval, Quebec, Canada
1 shared publicationR.P. Podgorsek
Laboratorium für Angewandte Physik, Gerhard–Mercator–Universität Duisburg, Lotharstraße 1-21, D-47048 Duisburg, Germany
1 shared publicationRobert P. Podgorsek
Department of Physics, University of Duisburg, Germany
1 shared publication
Latest Publications
- 1 January 2004
- Published by Springer Nature in Applied Physics B
- Vol. 78 (2) , 205-209
Electric field assisted holographic recording of surface relief gratings in an azo-glass
- 1 January 2004
- Published by Springer Nature in Applied Physics B
- Vol. 78 (2) , 205-209
Electric field assisted holographic recording of surface relief gratings in an azo-glass
- 1 February 2002
- Published by Optica Publishing Group in Applied Optics
- Vol. 41 (4) , 601-608
Selective optical detection of aromatic vapors
A sensitive layer system of amorphous Teflon AF on silver has been coated on a glass substrate. With a monochromatic light source the reflectivity of the layer system as a function of the angle of incidence exhibits the surface-plasmon resonance as well as a set of leaky-mode resonances. These optical resonance phenomena are sensitive to small refractive-index changes that may be induced by diffusion of particles into the Teflon AF layer. On the basis of this effect, the aromatic vapors benzene; toluene; and o-, p-, and m-xylene have been investigated with different vapor concentrations. By selection of a distinct angle at a particular resonance, dynamic measurements can be performed. Assuming a diffusion process in accordance with Fick’s law, the diffusion profile can be calculated as a function of time. As described by the Lorentz-Lorenz relation a refractive-index profile is induced that consequently interacts with the electromagnetic fields of the optical modes. With the function of the diffusion-induced refractive-index profile the shift of the resonance lines can be calculated from the measured reflectivity change as a function of time. The characteristic diffusion coefficients of the particular vapor allow for a distinction between the different types of aromate, even between the different xylenes.
- 1 February 2002
- Published by Optica Publishing Group in Applied Optics
- Vol. 41 (4) , 601-608
Selective optical detection of aromatic vapors
A sensitive layer system of amorphous Teflon AF on silver has been coated on a glass substrate. With a monochromatic light source the reflectivity of the layer system as a function of the angle of incidence exhibits the surface-plasmon resonance as well as a set of leaky-mode resonances. These optical resonance phenomena are sensitive to small refractive-index changes that may be induced by diffusion of particles into the Teflon AF layer. On the basis of this effect, the aromatic vapors benzene; toluene; and o-, p-, and m-xylene have been investigated with different vapor concentrations. By selection of a distinct angle at a particular resonance, dynamic measurements can be performed. Assuming a diffusion process in accordance with Fick’s law, the diffusion profile can be calculated as a function of time. As described by the Lorentz-Lorenz relation a refractive-index profile is induced that consequently interacts with the electromagnetic fields of the optical modes. With the function of the diffusion-induced refractive-index profile the shift of the resonance lines can be calculated from the measured reflectivity change as a function of time. The characteristic diffusion coefficients of the particular vapor allow for a distinction between the different types of aromate, even between the different xylenes.
- 1 August 1998
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 51 (1-3) , 348-354
Origin of optical anisotropy in planar polymer waveguides
- 1 August 1998
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 51 (1-3) , 348-354
Origin of optical anisotropy in planar polymer waveguides