Noel J. Ray
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Noel J. Ray has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Ailish Hannigan
5 shared publicationsFrancis M Burke
5 shared publicationsChristopher D Lynch
2 shared publications- Christopher D. Lynch
Tissue Engineering & Reparative Dentistry, School of Dentistry, Cardiff University, Cardiff, UK
2 shared publications A. Hannigan
Mathematics & Statistics, University of Limerick, Limerick, Ireland
1 shared publicationAudrey Hickey
Department of Restorative Dentistry, National University of Ireland, Cork, Ireland
1 shared publication
Latest Publications
- 1 October 2016
- Published by Elsevier in Journal of Dentistry
- Vol. 53, 22-29
The effect of endodontic access on all-ceramic crowns: A systematic review of in vitro studies
- 1 October 2016
- Published by Elsevier in Journal of Dentistry
- Vol. 53, 22-29
The effect of endodontic access on all-ceramic crowns: A systematic review of in vitro studies
- 5 March 2010
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 37 (4) , 278-282
Effect of pre‐heating on the viscosity and microhardness of a resin composite
Summary The effect of pre‐heating resin composite on pre‐cured viscosity and post‐cured surface hardness was evaluated. Groups of uncured specimens were heated to 60 °C and compared with control groups (24 °C) with respect to viscosity and surface hardness. Mean (SD) viscosities of the pre‐heated specimens (n = 15) were in the range of 285 (13)–377 (11) (Pa) compared with 642 (35)–800 (23) (Pa) at ambient temperature. There was a statistically significant difference between the two groups (P < 0·001). Mean (SD) Vickers microhardness (VHN) of the pre‐heated group (n = 15) was 68·6 (2·3) for the top surface and 68·7 (1·8) for the bottom surface measured at 24 h post curing (specimen thickness = 1·5 mm). The corresponding values for the room temperature group were 60·6 (1·4) and 59·0 (3·5). There was a statistically significant difference between corresponding measurements taken at the top and bottom for the pre‐heated and room temperature groups (P < 0·001). There was no significant difference between top and bottom measurements within each group. Pre‐heating resin composite reduces its pre‐cured viscosity and enhances its subsequent surface hardness. These effects may translate as easier placement together with an increased degree of polymerization and depth‐of‐cure.
- 5 March 2010
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 37 (4) , 278-282
Effect of pre‐heating on the viscosity and microhardness of a resin composite
Summary The effect of pre‐heating resin composite on pre‐cured viscosity and post‐cured surface hardness was evaluated. Groups of uncured specimens were heated to 60 °C and compared with control groups (24 °C) with respect to viscosity and surface hardness. Mean (SD) viscosities of the pre‐heated specimens (n = 15) were in the range of 285 (13)–377 (11) (Pa) compared with 642 (35)–800 (23) (Pa) at ambient temperature. There was a statistically significant difference between the two groups (P < 0·001). Mean (SD) Vickers microhardness (VHN) of the pre‐heated group (n = 15) was 68·6 (2·3) for the top surface and 68·7 (1·8) for the bottom surface measured at 24 h post curing (specimen thickness = 1·5 mm). The corresponding values for the room temperature group were 60·6 (1·4) and 59·0 (3·5). There was a statistically significant difference between corresponding measurements taken at the top and bottom for the pre‐heated and room temperature groups (P < 0·001). There was no significant difference between top and bottom measurements within each group. Pre‐heating resin composite reduces its pre‐cured viscosity and enhances its subsequent surface hardness. These effects may translate as easier placement together with an increased degree of polymerization and depth‐of‐cure.
- 1 September 2009
- Vol. 17 (3) , 134-6
Bonding auto-polymerising acrylic resin to acrylic denture teeth.
This study investigated the effect of surface treatments on the shear bond strength of an auto-polymerising acrylic resin cured to acrylic denture teeth. The surface treatments included a combination of grit-blasting and/or wetting the surface with monomer. Samples were prepared and then stored in water prior to shear testing. The results indicated that the application of monomer to the surface prior to bonding did not influence the bond strength. Grit blasting was found to significantly increase the bond strength.
- 1 September 2009
- Vol. 17 (3) , 134-6
Bonding auto-polymerising acrylic resin to acrylic denture teeth.
This study investigated the effect of surface treatments on the shear bond strength of an auto-polymerising acrylic resin cured to acrylic denture teeth. The surface treatments included a combination of grit-blasting and/or wetting the surface with monomer. Samples were prepared and then stored in water prior to shear testing. The results indicated that the application of monomer to the surface prior to bonding did not influence the bond strength. Grit blasting was found to significantly increase the bond strength.
- 1 December 2007
- Vol. 15 (4) , 146-52
Surface microhardness of a nanofilled resin composite: a comparison of a tungsten halogen and a light-emitting diode light curing unit, in vitro.
Surface microhardness numbers (VHN) have been measured and compared for disk specimens (thickness 1.5 mm) of a commercial nanofilled resin composite cured using a range of exposure times with a quartz tungsten halogen (QTH) and light-emitting diode (LED) light-curing unit (LCU), respectively. Each LCU requires different minimum exposure times to optimise VHN with respect to the internal controls but yield bottom surface/top surface VHN ratios > 0.95 with these optimised exposure times. Both LCUs produce comparable VHNs for the top surfaces at short exposure times but the QTH LCU requires increased exposure time for comparable results with the bottom surfaces. Overall, the LCUs are capable of producing comparable VHN numbers and VHN ratios within the parameters investigated.
- 1 December 2007
- Vol. 15 (4) , 146-52
Surface microhardness of a nanofilled resin composite: a comparison of a tungsten halogen and a light-emitting diode light curing unit, in vitro.
Surface microhardness numbers (VHN) have been measured and compared for disk specimens (thickness 1.5 mm) of a commercial nanofilled resin composite cured using a range of exposure times with a quartz tungsten halogen (QTH) and light-emitting diode (LED) light-curing unit (LCU), respectively. Each LCU requires different minimum exposure times to optimise VHN with respect to the internal controls but yield bottom surface/top surface VHN ratios > 0.95 with these optimised exposure times. Both LCUs produce comparable VHNs for the top surfaces at short exposure times but the QTH LCU requires increased exposure time for comparable results with the bottom surfaces. Overall, the LCUs are capable of producing comparable VHN numbers and VHN ratios within the parameters investigated.
- 1 March 2006
- Vol. 14 (1) , 7-12
Surface microhardness of a resin composite: a comparison of a tungsten halogen and a LED light curing unit, in vitro.
A comparison has been made between published surface microhardness numbers (VHN) of a commercial resin composite for different exposure times to a quartz tungsten halogen (QTH) and light-emitting diode (LED) light-curing unit (LCU). Both LCUs produced comparable hardness at both top and bottom surfaces, respectively, and similar bottom/top hardness ratios, for a specimen thickness of 1.5 mm, given sufficient exposure time (40 s) and an elapsed time of 24 h before measurement (for hardness numbers). However, some data are significantly different. There is no advantage in either LCU regarding optimal hardness and hardness ratios given an appropriate protocol. Immediate finishing (1 h) was more appropriate to the use of the LED LCU (with adequate exposure time). The effect of elapsed time after exposure on microhardness was more pronounced with the QTH LCU.
- 1 March 2006
- Vol. 14 (1) , 7-12
Surface microhardness of a resin composite: a comparison of a tungsten halogen and a LED light curing unit, in vitro.
A comparison has been made between published surface microhardness numbers (VHN) of a commercial resin composite for different exposure times to a quartz tungsten halogen (QTH) and light-emitting diode (LED) light-curing unit (LCU). Both LCUs produced comparable hardness at both top and bottom surfaces, respectively, and similar bottom/top hardness ratios, for a specimen thickness of 1.5 mm, given sufficient exposure time (40 s) and an elapsed time of 24 h before measurement (for hardness numbers). However, some data are significantly different. There is no advantage in either LCU regarding optimal hardness and hardness ratios given an appropriate protocol. Immediate finishing (1 h) was more appropriate to the use of the LED LCU (with adequate exposure time). The effect of elapsed time after exposure on microhardness was more pronounced with the QTH LCU.
- 1 December 2005
- Vol. 13 (4) , 177-81
Early surface microhardness of a resin composite exposed to a pulse-delayed curing exposure: a comparison of a tungsten halogen and a plasma arc lamp, in vitro.
Surface microhardness numbers of a commercial resin composite have been compared after exposure to a quartz tungsten halogen (QTH) and plasma arc (PAC) lamp respectively, using two exposure protocols. The effect of increased tip-to-composite distance has also been compared. Exposure with the PAC lamp tested is more appropriate to the early finishing of composite restorations after placement and curing than with the QTH. However both lamps were capable of producing comparable surface hardness, with appropriate exposure protocols. The effect of increased tip-to-composite distance was generally not significant between the lamps for continuous exposure.
- 1 December 2005
- Vol. 13 (4) , 177-81
Early surface microhardness of a resin composite exposed to a pulse-delayed curing exposure: a comparison of a tungsten halogen and a plasma arc lamp, in vitro.
Surface microhardness numbers of a commercial resin composite have been compared after exposure to a quartz tungsten halogen (QTH) and plasma arc (PAC) lamp respectively, using two exposure protocols. The effect of increased tip-to-composite distance has also been compared. Exposure with the PAC lamp tested is more appropriate to the early finishing of composite restorations after placement and curing than with the QTH. However both lamps were capable of producing comparable surface hardness, with appropriate exposure protocols. The effect of increased tip-to-composite distance was generally not significant between the lamps for continuous exposure.
- 24 November 2004
- Vol. 35 (10) , 795-800
In vitro study of surface microhardness of a resin composite exposed to a quartz-halogen lamp.
To determine the minimum exposure times consistent with optimized surface microhardness numbers (VHN) for the top and bottom surfaces, respectively, of a resin composite (1.5-mm depth) cured using a quartz-halogen activation lamp. Additionally, to determine the conditions appropriate to achieve optimized bottom/top hardness ratios. Disk specimens of a commercial resin composite restorative (Spectrum TPH) were exposed to a quartz-halogen lamp, and VHNs were measured for the top and bottom surfaces at elapsed times of 1 hour and 24 hours. Data were dependent on exposure time, time elapsed after exposure, and the surface involved. Exposure time featured limiting values in excess of which no significant increase in microhardness took place. All microhardness data increased significantly over an elapsed time interval between 1 hour and 24 hours postexposure. Microhardness ratios (bottom/top) were dependent on exposure time only and were not influenced by time elapsed after exposure. Minimum exposure time may be considered as the greater of the times to achieve optimized top hardness and optimized hardness ratio, respectively.
- 24 November 2004
- Vol. 35 (10) , 795-800
In vitro study of surface microhardness of a resin composite exposed to a quartz-halogen lamp.
To determine the minimum exposure times consistent with optimized surface microhardness numbers (VHN) for the top and bottom surfaces, respectively, of a resin composite (1.5-mm depth) cured using a quartz-halogen activation lamp. Additionally, to determine the conditions appropriate to achieve optimized bottom/top hardness ratios. Disk specimens of a commercial resin composite restorative (Spectrum TPH) were exposed to a quartz-halogen lamp, and VHNs were measured for the top and bottom surfaces at elapsed times of 1 hour and 24 hours. Data were dependent on exposure time, time elapsed after exposure, and the surface involved. Exposure time featured limiting values in excess of which no significant increase in microhardness took place. All microhardness data increased significantly over an elapsed time interval between 1 hour and 24 hours postexposure. Microhardness ratios (bottom/top) were dependent on exposure time only and were not influenced by time elapsed after exposure. Minimum exposure time may be considered as the greater of the times to achieve optimized top hardness and optimized hardness ratio, respectively.
- 1 September 2002
- Vol. 10 (3) , 107-11
Surface microhardness of a resin composite exposed to pulse-delayed plasma arc lamp irradiation, in vitro.
Groups of samples of a light-activated resin composite were exposed, using a 3-step pulse-delayed protocol, to a plasma arc unit. Further groups were exposed with the light-curing guide positioned at increasing distances from the composite surface. The pulse-delayed protocol yielded a progressive increase in microhardness number at the end of each step but with a maximum mean value significantly less than the controls. Increasing the irradiation distance yielded a progressive and significant decrease in microhardness number.
- 1 September 2002
- Vol. 10 (3) , 107-11
Surface microhardness of a resin composite exposed to pulse-delayed plasma arc lamp irradiation, in vitro.
Groups of samples of a light-activated resin composite were exposed, using a 3-step pulse-delayed protocol, to a plasma arc unit. Further groups were exposed with the light-curing guide positioned at increasing distances from the composite surface. The pulse-delayed protocol yielded a progressive increase in microhardness number at the end of each step but with a maximum mean value significantly less than the controls. Increasing the irradiation distance yielded a progressive and significant decrease in microhardness number.