  • Current Status on the Development of a Totally Implantable Biventricular Assist Device: The Baylor Gyro BVAD

    by J. Linneweber, K. Nonaka, S. Ichikawa, H. Ishitoya, T. Motomura, Y. Nosé

    Objective: The Baylor Gyro BVAD® is under development with the final goal of establishing a totally implantable biventricular assist system (BVAD). The aim of this study was to evaluate the safety, reliability, and effectiveness of the device in a long-term in vivo model. Methods: The BVAD was implanted into eight calves for longer than 4 weeks in a biventricular bypass fashion, with the native heart remaining. Pump performance was assessed with the system's digital data acquisition unit. Postoperatively, anticoagulation was maintained with i.v. heparin perfusion (ACT≤ 250 sec) gradually replaced by coumadin. Treadmill exercise tests were performed daily following a 10-day reconvalescence period after surgery. Results: The animals were kept alive for 37 - 90 days. The pumps yielded average flows of 5.3 ± 1.1 l/min and 4.9 ± 0.7 l/min for the LVAD and RVAD, respectively. Power consumption was 8.2 ± 2.7 W and 9.6 ± 4.7 W at 1935 ± 123 rpm and 2015 ± 365 rpm, respectively. All cases exhibited low hemolysis; renal and liver function were kept normal throughout the experiments. The animals demonstrated no thromboembolic neurological symptoms and tolerated moderate treadmill exercise. Conclusion: The Baylor Gyro BVAD demonstrated effective and reliable in vivo performance with acceptable biocompatibility. Based on these studies, we conclude that the system will be suitable as a long-term totally implantable BVAD for uses intended for longer than two years.


  • Development of the Baylor Gyro Permanently Implantable Centrifugal Blood Pump as a Biventricular Assist Device

    by Kenji Nonaka, Joerg Linneweber, Seiji Ichikawa, Masaharu Yoshikawa, Shinji Kawahito, Minoru Mikami, Tadashi Motomura, Hiroshi Ishitoya, Ikuya Nishimura, Daniel Oestmann, et al.

    The Baylor Gyro permanently implantable centrifugal blood pump (Gyro PI pump) has been under development since 1995 at Baylor College of Medicine. Excellent results were achieved as a left ventricular assist device (LVAD) with survival up to 284 days. Based on these results, we are now focusing on the development of a biventricular assist device (BVAD) system, which requires 2 pumps to be implanted simultaneously in the preperitoneal space. Our hypothesis was that the Gyro PI pump would be an appropriate device for an implantable BVAD system. The Gyro PI 700 pump is fabricated from titanium alloy and has a 25 ml priming volume, pump weight of 204 g, height of 45 mm, and pump diameter of 65 mm. This pump can provide 5 L/min against 100 mm Hg at 2,000 rpm. In this study, 6 half‐Dexter healthy calves have been used as the experimental model. The right pump was applied between the infundibular of the right ventricle and the main pulmonary artery. The left pump was applied between the apex of the left ventricle and the thoracic descending aorta. As for anticoagulation, heparin was administered at the first postoperative week and then converted to warfarin sodium from the second week after surgery. Both pump flow rates were controlled maintaining a pulmonary arterial flow of less than 160 ml/kg/min for the sake of avoidance of pulmonary congestion. Blood sampling was done to assess visceral organ function, and the data regarding pump performance were collected. After encountering the endpoint, which the study could not keep for any reasons, necropsy and histopathological examinations were performed. The first 2 cases were terminated within 1 week. Deterioration of the pump flow due to suction phenomenon was recognized in both cases. To avoid the suction phenomenon, a flexible conduit attached on the inlet conduit was designed and implanted. After using the flexible inflow conduit, the required power and the rotational speed were reduced. Furthermore, the suction phenomenon was not observed except for 1 case. There was no deterioration regarding visceral organ function, and pulmonary function was maintained within normal range except for 1 case. Even though the experimental animal survived up to 45 days with the flexible inflow conduit, an increase in power consumption due to thrombus formation behind the impeller became a problem. Lower rotational speed, which was probably produced by the effectiveness of the flexible inflow conduit, was speculated to be one of the reasons. And the minimum range of rotational speed was 1,950 rpm in these 6 BVAD cases and the previous 3 cases of LVAD. In conclusion, 6 cases of BVAD implantation were performed as in vivo animal studies and were observed up to 45 days. The flexible inflow conduit was applied in 4 of 6 cases, and it was effective in avoiding a suction phenomenon. The proper rotational speed of the Gyro PI 700 pump was detected from the viewpoint of antithrombogenicity, which is more than 1,950 rpm.


    • 1 December 2000
      • Vol. 6  (6) , 373-7

    Development of a new silicone membrane oxygenator for ECMO.

    by K Nakata, T Maeda, S Murabayashi, M Yoshikawa, T Takano, A Iwasaki, K Nonaka, J Linneweber, S Kawahito, J Glueck, et al.

    Two types small and efficient ECMO oxygenators were developed utilizing the most up to date hollow fiber technology. Newly silicone hollow fibers possess sufficient mechanical strength while maintaining ultra thin walls of 50 micro meter. Two types of oxygenators were made with this fiber. The fiber length for the type 1 module is 150mm with a priming volume 194 cc (surface area 1.3 m(2)) and type 2 has a fiber length of 100 mm with a 144 cc priming volume (the surface area 0.8 m(2)). The studies were performed at 0.5, 1.0 and 2.0 L/min of blood flow and these oxygenators demonstrated. O(2) gas transfer rate of 69+/-4 ml/min/L for type 1 and 68+/-6 ml/min/L for type 2. The CO(2) gas transfer rate was 25+/-2 ml/min/L for type 1 and 32+/-2 ml/min/L for type 2. These results demonstrate type 2 oxygenator has similar gas exchange capabilities to those of Kolobows' oxygenator which has about 2.0 times larger surface area. Additionally, comparative hemolysis tests were preformed with this new oxygenator and the Kolbow. The NIH value was 0.006 (g/100 L) for the type 1 oxygenator and 0.01 (g/100 L) for the Kolbow oxygenator. These results suggested that this ECMO oxygenator had sufficient gas exchange performance in spite of being smaller and induced minimal blood damage.