Will Hansen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Will Hansen has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
C. Borgnakke
Department of Mechanical Engineering , University of Michigan , Ann Arbor , MI , USA
1 shared publicationClaus Borgnakke
1 shared publicationD. L. Smiley
Michigan Department of Transportation , P. O. Box 30049, Lansing, MI, 48909, USA
1 shared publication- Elin Jensen
Department of Civil and Architectural Engineering, Lawrence Technological University, Southfield, MI 48075, USA
1 shared publication Y. Kang
Department of Civil & Environmental Engineering , University of Michigan , Ann Arbor , MI , USA
1 shared publicationY. Peng
Department of Civil and Environmental Engineering , University of Michigan , 2350 Hayward, Ann Arbor, MI, 48109, USA
1 shared publication
Latest Publications
- Open Access
- 22 January 2025
- Published by International Society for Concrete Pavements, Inc in Proceedings of the International Conference on Concrete Pavements
Cryogenic Suction-A Major Salt Scaling Mechanism in Highway Concrete
Combined salt and frost attack is a major durability problem in concrete highway pavements in the state of Michigan, USA, where road-salts are used extensively for ice melting purposes. Previous studies have shown that continuous measurement of length-change during a freeze-thaw cycle is an effective tool in indentifying frost mechanisms. In this study the focus was to evaluate the cryogenic suction effect on frost expansion. The net frost expansion (linear dilation) was determined by monitoring the change in length of air-entrained concrete specimens undergoing a freeze-thaw cycle between 20 °C and -20 °C. Two dilation processes were found during freezing, an initial dilation at the freezing point (independent of surface exposure liquid), and a subsequent dilation, which is only found when a salt solution is present on the surface. Specimen expansion continues during the entire freezing period, including a 3 hour ramp at constant temperature (-20 °C). This secondary dilation dominates when the surface is exposed to a deicer solution. At constant temperature below initial freezing point, cryogenic suction of surface liquid (i.e., 3% salt solution) was found to be a major factor in sub-zero liquid transport that causes frost expansion in concrete. During this process, air voids are being filled as well and air is being displaced. Some air near the surface can escape. This was observed at -20 °C where escaping air was trapped in the liquid surface layer.
- 22 January 2025
- Published by International Society for Concrete Pavements, Inc in Proceedings of the International Conference on Concrete Pavements
Open AccessCryogenic Suction-A Major Salt Scaling Mechanism in Highway Concrete
Combined salt and frost attack is a major durability problem in concrete highway pavements in the state of Michigan, USA, where road-salts are used extensively for ice melting purposes. Previous studies have shown that continuous measurement of length-change during a freeze-thaw cycle is an effective tool in indentifying frost mechanisms. In this study the focus was to evaluate the cryogenic suction effect on frost expansion. The net frost expansion (linear dilation) was determined by monitoring the change in length of air-entrained concrete specimens undergoing a freeze-thaw cycle between 20 °C and -20 °C. Two dilation processes were found during freezing, an initial dilation at the freezing point (independent of surface exposure liquid), and a subsequent dilation, which is only found when a salt solution is present on the surface. Specimen expansion continues during the entire freezing period, including a 3 hour ramp at constant temperature (-20 °C). This secondary dilation dominates when the surface is exposed to a deicer solution. At constant temperature below initial freezing point, cryogenic suction of surface liquid (i.e., 3% salt solution) was found to be a major factor in sub-zero liquid transport that causes frost expansion in concrete. During this process, air voids are being filled as well and air is being displaced. Some air near the surface can escape. This was observed at -20 °C where escaping air was trapped in the liquid surface layer.
- 1 March 2012
- Published by Taylor & Francis in International Journal of Pavement Engineering
- Vol. 13 (3) , 259-266
Effect of air-void system on frost expansion of highway concrete exposed to deicer salt
The net frost expansion (dilation) was determined by monitoring the change in length of air-entrained concrete specimens undergoing a freeze–thaw cycle between 20°C and − 20°C. Two dilation processes were found during freezing: an initial dilation at the freezing point and a subsequent dilation which continues during the entire freezing period. The second dilation dominates when the surface is exposed to a deicer solution. For both exposure conditions, a good correlation was found between the dilation and the spacing factor, which fits well with the hydraulic pressure theory. The results show that a lower spacing factor is required for frost protection against salt frost attack, consistent with the current practice of recommending higher total air content as compared to freezing without salt exposure. Concretes that had excellent field durability had frost dilation values below the paste fracture strain of about 250 micro strains. The dilation results suggest that cryogenic suction of external liquid exacerbates internal hydraulic pressure development which in turn may explain the surface scaling phenomenon.
- 1 March 2012
- Published by Taylor & Francis in International Journal of Pavement Engineering
- Vol. 13 (3) , 259-266
Effect of air-void system on frost expansion of highway concrete exposed to deicer salt
The net frost expansion (dilation) was determined by monitoring the change in length of air-entrained concrete specimens undergoing a freeze–thaw cycle between 20°C and − 20°C. Two dilation processes were found during freezing: an initial dilation at the freezing point and a subsequent dilation which continues during the entire freezing period. The second dilation dominates when the surface is exposed to a deicer solution. For both exposure conditions, a good correlation was found between the dilation and the spacing factor, which fits well with the hydraulic pressure theory. The results show that a lower spacing factor is required for frost protection against salt frost attack, consistent with the current practice of recommending higher total air content as compared to freezing without salt exposure. Concretes that had excellent field durability had frost dilation values below the paste fracture strain of about 250 micro strains. The dilation results suggest that cryogenic suction of external liquid exacerbates internal hydraulic pressure development which in turn may explain the surface scaling phenomenon.
- 24 November 2006
- Published by Taylor & Francis in International Journal of Pavement Engineering
- Vol. 7 (4) , 291-296
Effects of paving conditions on built-in curling and pavement performance
The effective temperature difference between the slab's top and bottom at time of final set is an important input parameter for the recently developed mechanistic-empirical pavement design guide (M-EPDG). However, very limited guidelines are available for the selection of this parameter. The major focus of this work is to quantify built-in curl from field temperature measurements for Michigan pavements. The results of this study show that built-in curl can be substantial for hot weather paving conditions. Early morning paving on a sunny summer day allows a maximum positive (i.e. top warmer than bottom) temperature difference at time of final set due to maximum heat of hydration and added solar radiation effects. The temperature difference between the slab's top and bottom was found to be 10–12°C. Consequently, the slab stays flat and in full contact with the base from this time only if this range is maintained. Unfortunately, this only occurs for a short time-period near mid-day, so the slab is mostly in a permanently upward curled condition. For late fall temperature conditions, the difference was slightly negative (about − 2°C) at time of set. Late fall construction therefore is favorable for maintaining slab–base contact. Despite combined built-in curl and daily curling changes, slab stress predictions using finite element analysis (ISLAB2000) for multi-axle loading at joints found the total stresses for a typical summertime 24 h period to be below the tensile stress necessary to initiate fatigue failure (i.e. below 45% of the flexure strength). This suggests that additional slab uplift from moisture warping is a factor for top–down cracking to develop.
- 24 November 2006
- Published by Taylor & Francis in International Journal of Pavement Engineering
- Vol. 7 (4) , 291-296
Effects of paving conditions on built-in curling and pavement performance
The effective temperature difference between the slab's top and bottom at time of final set is an important input parameter for the recently developed mechanistic-empirical pavement design guide (M-EPDG). However, very limited guidelines are available for the selection of this parameter. The major focus of this work is to quantify built-in curl from field temperature measurements for Michigan pavements. The results of this study show that built-in curl can be substantial for hot weather paving conditions. Early morning paving on a sunny summer day allows a maximum positive (i.e. top warmer than bottom) temperature difference at time of final set due to maximum heat of hydration and added solar radiation effects. The temperature difference between the slab's top and bottom was found to be 10–12°C. Consequently, the slab stays flat and in full contact with the base from this time only if this range is maintained. Unfortunately, this only occurs for a short time-period near mid-day, so the slab is mostly in a permanently upward curled condition. For late fall temperature conditions, the difference was slightly negative (about − 2°C) at time of set. Late fall construction therefore is favorable for maintaining slab–base contact. Despite combined built-in curl and daily curling changes, slab stress predictions using finite element analysis (ISLAB2000) for multi-axle loading at joints found the total stresses for a typical summertime 24 h period to be below the tensile stress necessary to initiate fatigue failure (i.e. below 45% of the flexure strength). This suggests that additional slab uplift from moisture warping is a factor for top–down cracking to develop.