Judith Rishpon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Judith Rishpon has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Leah Reshef
Department of Molecular Microbiology and Biotechnology, The George S. Wise Faculty of Life Sciences, Tel Aviv University, Tel Aviv, Israel
2 shared publications Michal Badihi‐Mossberg
2 shared publications- Uri Gophna
The Shmunis School of Biomedicine and Cancer Research, Faculty of Life Sciences, Tel Aviv University, Tel Aviv, Israel
2 shared publications - David Lee Kaplan
Department of Biomedical Engineering, Tufts University, Medford, MA, USA
1 shared publication - Ehud Gazit
Tel Aviv University
1 shared publication Gal Markel
Department of Physical Electronics, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel
1 shared publication
Latest Publications
- Open Access
- 30 November 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (23) , 8570
Specific Desulfuromonas Strains Can Determine Startup Times of Microbial Fuel Cells
Microbial fuel cells (MFCs) can generate electricity simultaneously with wastewater treatment. For MFCs to be considered a cost-effective treatment technology, they should quickly re-establish a stable electroactive microbial community in the case of system failure. In order to shorten startup times, temporal studies of anodic biofilm development are required, however, frequent sampling can reduce the functionality of the system due to electroactive biomass loss; therefore, on-line monitoring of the microbial community without interfering with the system’s stability is essential. Although all anodic biofilms were composed of Desulfuromonadaceae, MFCs differed in startup times. Generally, a Desulfuromonadaceae-dominated biofilm was associated with faster startup MFCs. A positive PCR product of a specific 16S rRNA gene PCR primer set for detecting the acetate-oxidizing, Eticyclidine (PCE)-dechlorinating Desulfuromonas group was associated with efficient MFCs in our samples. Therefore, this observation could serve as a biomarker for monitoring the formation of an efficient anodic biofilm. Additionally, we successfully enriched an electroactive consortium from an active anode, also resulting in a positive amplification of the specific primer set. Direct application of this enrichment to a clean MFC anode showed a substantial reduction of startup times from 18 to 3 days.
- 30 November 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (23) , 8570
Open AccessSpecific Desulfuromonas Strains Can Determine Startup Times of Microbial Fuel Cells
Microbial fuel cells (MFCs) can generate electricity simultaneously with wastewater treatment. For MFCs to be considered a cost-effective treatment technology, they should quickly re-establish a stable electroactive microbial community in the case of system failure. In order to shorten startup times, temporal studies of anodic biofilm development are required, however, frequent sampling can reduce the functionality of the system due to electroactive biomass loss; therefore, on-line monitoring of the microbial community without interfering with the system’s stability is essential. Although all anodic biofilms were composed of Desulfuromonadaceae, MFCs differed in startup times. Generally, a Desulfuromonadaceae-dominated biofilm was associated with faster startup MFCs. A positive PCR product of a specific 16S rRNA gene PCR primer set for detecting the acetate-oxidizing, Eticyclidine (PCE)-dechlorinating Desulfuromonas group was associated with efficient MFCs in our samples. Therefore, this observation could serve as a biomarker for monitoring the formation of an efficient anodic biofilm. Additionally, we successfully enriched an electroactive consortium from an active anode, also resulting in a positive amplification of the specific primer set. Direct application of this enrichment to a clean MFC anode showed a substantial reduction of startup times from 18 to 3 days.
- 1 July 2016
- Published by Elsevier in Bioresource Technology
- Vol. 212, 151-159
Community structure dynamics during startup in microbial fuel cells – The effect of phosphate concentrations
- 1 July 2016
- Published by Elsevier in Bioresource Technology
- Vol. 212, 151-159
Community structure dynamics during startup in microbial fuel cells – The effect of phosphate concentrations
- 9 July 2014
- Published by Wiley in Electroanalysis
- Vol. 26 (8) , 1671-1675
A Direct Electrochemical Detection Method of Melanoma Based on Melanoma Biomarker
A new method of detecting and diagnosing melanoma based on melanoma biomarker was developed and its feasibility demonstrated. The method is based on an electrochemical biosensor platform comprised of a special biochip and device, performing a multi‐channel amperometric detection of the enzymatic activity of tyrosinase, an enzyme biomarker of melanoma. The newly developed biosensor platform is able to electrochemically detect tyrosinase activity in fresh biopsy samples. This bioelectrochemical detection method is rapid, yielding results within minutes from biopsy removal. Using “as is” biopsy samples, without pretreatment, simplifies the process, saves time and reduces cost and labor dramatically. Using modern portable microelectronics provides an accurate biomarker expression measurement at the “point of care” increasing the accessibility of new bio‐chip technologies to the public.
- 9 July 2014
- Published by Wiley in Electroanalysis
- Vol. 26 (8) , 1671-1675
A Direct Electrochemical Detection Method of Melanoma Based on Melanoma Biomarker
A new method of detecting and diagnosing melanoma based on melanoma biomarker was developed and its feasibility demonstrated. The method is based on an electrochemical biosensor platform comprised of a special biochip and device, performing a multi‐channel amperometric detection of the enzymatic activity of tyrosinase, an enzyme biomarker of melanoma. The newly developed biosensor platform is able to electrochemically detect tyrosinase activity in fresh biopsy samples. This bioelectrochemical detection method is rapid, yielding results within minutes from biopsy removal. Using “as is” biopsy samples, without pretreatment, simplifies the process, saves time and reduces cost and labor dramatically. Using modern portable microelectronics provides an accurate biomarker expression measurement at the “point of care” increasing the accessibility of new bio‐chip technologies to the public.
Characterization of Peptide‐Nanostructure‐Modified Electrodes and Their Application for Ultrasensitive Environmental Monitoring
Dense arrays of self‐assembled nanostructures are highly important for the fabrication of high‐performance sensors of large surface area. The organized incorporation of novel biocompatible organic nanostructures into extremely sensitive amperometric biosensors is demonstrated. Peptide nanoforest biosensors for phenol detection were 17‐fold more sensitive than uncoated electrode and more sensitive than those modified with carbon nanotubes or combined coating. The high sensitivity reported, together with the biocompatibility and the ability to chemically and biologically modify these elements, may provide a novel platform for biosensors design and fabrication for environmental monitoring, homeland security, and other applications.
Characterization of Peptide‐Nanostructure‐Modified Electrodes and Their Application for Ultrasensitive Environmental Monitoring
Dense arrays of self‐assembled nanostructures are highly important for the fabrication of high‐performance sensors of large surface area. The organized incorporation of novel biocompatible organic nanostructures into extremely sensitive amperometric biosensors is demonstrated. Peptide nanoforest biosensors for phenol detection were 17‐fold more sensitive than uncoated electrode and more sensitive than those modified with carbon nanotubes or combined coating. The high sensitivity reported, together with the biocompatibility and the ability to chemically and biologically modify these elements, may provide a novel platform for biosensors design and fabrication for environmental monitoring, homeland security, and other applications.
- 25 November 2008
- Published by Wiley in Electroanalysis
- Vol. 20 (23) , 2592-2594
An Electrochemical Immunosensor for C‐Reactive Protein Based on Multi‐Walled Carbon Nanotube‐Modified Electrodes
C‐reactive protein (CRP) is a nonspecific biomarker of inflammation and infection that can be used as a predictive risk marker of cardiovascular disease in asymptomatic individuals or as a prognostic marker of recurrent ischemia and death among patients with coronary heart disease or stroke. We developed a sensitive, disposable, and easy to operate sensor based on heterogeneous sandwich immunoassay for high sensitivity CRP (hs‐CRP) measurement. We used screen‐printed electrodes modified with multi‐walled carbon nanotubes and protein A to ensure the oriented immobilization of anti‐CRP antibodies. CRP was quantitatively measured down to a concentration of 0.5 ng mL−1, enabling high dilution of the samples before measurement and consequently reducing interferences present in the serum. The sensor developed is suitable for point of care detection of hs‐CRP at clinically relevant concentrations for the diagnosis of both conventional and low‐grade inflammations.
- 25 November 2008
- Published by Wiley in Electroanalysis
- Vol. 20 (23) , 2592-2594
An Electrochemical Immunosensor for C‐Reactive Protein Based on Multi‐Walled Carbon Nanotube‐Modified Electrodes
C‐reactive protein (CRP) is a nonspecific biomarker of inflammation and infection that can be used as a predictive risk marker of cardiovascular disease in asymptomatic individuals or as a prognostic marker of recurrent ischemia and death among patients with coronary heart disease or stroke. We developed a sensitive, disposable, and easy to operate sensor based on heterogeneous sandwich immunoassay for high sensitivity CRP (hs‐CRP) measurement. We used screen‐printed electrodes modified with multi‐walled carbon nanotubes and protein A to ensure the oriented immobilization of anti‐CRP antibodies. CRP was quantitatively measured down to a concentration of 0.5 ng mL−1, enabling high dilution of the samples before measurement and consequently reducing interferences present in the serum. The sensor developed is suitable for point of care detection of hs‐CRP at clinically relevant concentrations for the diagnosis of both conventional and low‐grade inflammations.
- 2 October 2007
- Published by Wiley in Electroanalysis
- Vol. 19 (19-20) , 2015-2028
Electrochemical Biosensors for Pollutants in the Environment
This article reviews recent advances in electrochemical biosensing and detection of environmental pollutants. Electrochemical biosensors offer precision, sensitivity, rapidity, and ease of operation for on‐site environmental analysis. An electrochemical biosensor is an analytical device in which a specific biological recognition element (bioreceptor) is integrated within or intimately associated with an electrode (transducer) that converts the recognition event to a measurable electrical signal for the purpose of detecting a target compound (analyte) in solution. This approach not only provides the means for on‐site analysis but also removes the time delay and sample alteration that can occur during transport to a centralized laboratory. We first address the basic principles of merging of electrochemistry and biology into a biosensing system, and then we discuss various environmental monitoring strategies involving this technology.
- 2 October 2007
- Published by Wiley in Electroanalysis
- Vol. 19 (19-20) , 2015-2028
Electrochemical Biosensors for Pollutants in the Environment
This article reviews recent advances in electrochemical biosensing and detection of environmental pollutants. Electrochemical biosensors offer precision, sensitivity, rapidity, and ease of operation for on‐site environmental analysis. An electrochemical biosensor is an analytical device in which a specific biological recognition element (bioreceptor) is integrated within or intimately associated with an electrode (transducer) that converts the recognition event to a measurable electrical signal for the purpose of detecting a target compound (analyte) in solution. This approach not only provides the means for on‐site analysis but also removes the time delay and sample alteration that can occur during transport to a centralized laboratory. We first address the basic principles of merging of electrochemistry and biology into a biosensing system, and then we discuss various environmental monitoring strategies involving this technology.
- 2 November 2006
- Published by Wiley in Electroanalysis
- Vol. 18 (21) , 2049-2054
Collagen‐Like Peptide as a Matrix for Enzyme Immobilization in Electrochemical Biosensors
An efficient enzyme immobilization technique is described in which well‐organized collagen peptide monolayers are used as a scaffold upon which horseradish peroxidase is anchored on gold electrode surfaces. The resulting electrode presents reproducible amperometric responses at an applied potential of −0.1 V with a range of linearity for peroxides. These results suggest that triple helical collagen can be used for specific immobilization of HRP with advantages of low price, simplicity and biocompatibility. The results are significant for the control of biomolecular self‐assembly in the intrinsic electric devices.
- 2 November 2006
- Published by Wiley in Electroanalysis
- Vol. 18 (21) , 2049-2054
Collagen‐Like Peptide as a Matrix for Enzyme Immobilization in Electrochemical Biosensors
An efficient enzyme immobilization technique is described in which well‐organized collagen peptide monolayers are used as a scaffold upon which horseradish peroxidase is anchored on gold electrode surfaces. The resulting electrode presents reproducible amperometric responses at an applied potential of −0.1 V with a range of linearity for peroxides. These results suggest that triple helical collagen can be used for specific immobilization of HRP with advantages of low price, simplicity and biocompatibility. The results are significant for the control of biomolecular self‐assembly in the intrinsic electric devices.