Matthew H. Smith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matthew H. Smith has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Arthur Lompado
M. H. Smith (SmithMH@.uah.edu), A. Lompado, and L. W. Hillman are with the Department of Physics, University of Alabama, Huntsville, Alabama 35899.K. R. Denninghoff is with the Department of Emergency Medicine, University of Alabama, Birmingham, Alabama 35294
1 shared publicationKurt R. Denninghoff
M. H. Smith (SmithMH@.uah.edu), A. Lompado, and L. W. Hillman are with the Department of Physics, University of Alabama, Huntsville, Alabama 35899.K. R. Denninghoff is with the Department of Emergency Medicine, University of Alabama, Birmingham, Alabama 35294
1 shared publicationLloyd W. Hillman
M. H. Smith (SmithMH@.uah.edu), A. Lompado, and L. W. Hillman are with the Department of Physics, University of Alabama, Huntsville, Alabama 35899.K. R. Denninghoff is with the Department of Emergency Medicine, University of Alabama, Birmingham, Alabama 35294
1 shared publication
Latest Publications
- 1 March 2000
- Published by Optica Publishing Group in Applied Optics
- Vol. 39 (7) , 1183-1193
Effect of multiple light paths on retinal vessel oximetry
Techniques for noninvasively measuring the oxygen saturation of blood in retinal arteries and veins are reported in the literature, but none have been sufficiently accurate and reliable for clinical use. Addressing the need for increased accuracy, we present a series of oximetric equations that explicitly consider the effects of backscattering by red blood cells and lateral diffusion of light in the ocular fundus. The equations are derived for the specific geometry of a scanning-beam retinal vessel oximeter; however, the results should also be applicable to photographic oximeters. We present in vitro and in vivo data that suggest the validity of these equations.
- 1 March 2000
- Published by Optica Publishing Group in Applied Optics
- Vol. 39 (7) , 1183-1193
Effect of multiple light paths on retinal vessel oximetry
Techniques for noninvasively measuring the oxygen saturation of blood in retinal arteries and veins are reported in the literature, but none have been sufficiently accurate and reliable for clinical use. Addressing the need for increased accuracy, we present a series of oximetric equations that explicitly consider the effects of backscattering by red blood cells and lateral diffusion of light in the ocular fundus. The equations are derived for the specific geometry of a scanning-beam retinal vessel oximeter; however, the results should also be applicable to photographic oximeters. We present in vitro and in vivo data that suggest the validity of these equations.
- 1 January 1999
- Published by Optica Publishing Group in Applied Optics
- Vol. 38 (1) , 258-267
Optimum wavelength combinations for retinal vessel oximetry
Several investigators have demonstrated techniques for noninvasive measurement of the oxygen saturation of blood in retinal arteries and veins. These techniques have been based on measuring the optical density of a retinal vessel at multiple wavelengths and on calculating the oxygen saturation on the basis of the known absorption coefficients of hemoglobin and oxyhemoglobin. A technique is presented for determining the optimum wavelengths for retinal oximetry measurements. What is believed to be a novel wavelength combination of 488, 635, and 905 nm is found to provide excellent oxygen sensitivity across a broad range of typical vessel diameters and saturations. The use of this wavelength combination should allow for the most accurate retinal saturation measurements made to date.
- 1 January 1999
- Published by Optica Publishing Group in Applied Optics
- Vol. 38 (1) , 258-267
Optimum wavelength combinations for retinal vessel oximetry
Several investigators have demonstrated techniques for noninvasive measurement of the oxygen saturation of blood in retinal arteries and veins. These techniques have been based on measuring the optical density of a retinal vessel at multiple wavelengths and on calculating the oxygen saturation on the basis of the known absorption coefficients of hemoglobin and oxyhemoglobin. A technique is presented for determining the optimum wavelengths for retinal oximetry measurements. What is believed to be a novel wavelength combination of 488, 635, and 905 nm is found to provide excellent oxygen sensitivity across a broad range of typical vessel diameters and saturations. The use of this wavelength combination should allow for the most accurate retinal saturation measurements made to date.