RNRabah Nedir

Rabah Nedir

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rabah Nedir has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 4 November 2009
      • Vol. 24  (4) , 727-33

    Placement of tapered implants using an osteotome sinus floor elevation technique without bone grafting: 1-year results.

    by Rabah Nedir, Nathalie Nurdin, Serge Szmukler-Moncler, Mark Bischof

    Achieving implant primary stability in poor-density bone is difficult when the available bone height is less than 6 mm. This study assesses the 1-year clinical performance of tapered implants in sites of reduced height in combination with osteotome sinus floor elevation without bone grafting material. An osteotome sinus floor elevation procedure without grafting material was performed in the atrophic posterior maxilla. Tapered implants were placed in maxillary sites with residual bone height of 1 to 6 mm. Implant primary stability was assessed by finger pressure exerted on the implant. Bone gain in the elevated sinus and crestal bone loss were evaluated at 1 year via radiographs. Fifty-four tapered implants were placed in 32 patients and were loaded after a mean of 4.2 +/- 1.6 months. The mean maxillary residual bone height was 3.8 +/- 1.2 mm. All implants achieved primary stability, and all were successfully loaded. At the 1-year radiographic control, the mean bone gain within the sinus was 2.5 +/- 1.7 mm and the mean crestal bone loss was 0.2 +/- 0.8 mm. In the atrophic posterior maxilla, primary stability can readily be achieved with tapered implants, even when the mean residual bone height is 3.8 mm. Despite limited bone support and lack of grafting material, all loaded implants were clinically stable, and crestal bone loss was limited. A net bone gain of 2.3 +/- 1.8 mm was observed. Survival and success rates were 100% and 94.4%, respectively. Elevation of the sinus membrane without the addition of bone grafting material led to bone formation beyond the original limit of the sinus floor.


  • Osteotome sinus floor elevation technique without grafting material: 3‐year results of a prospective pilot study

    by Rabah Nedir, Mark Bischof, Lydia Vazquez, Nathalie Nurdin, Serge Szmukler‐Moncler, Jean‐Pierre Bernard

    Objective: In a prospective pilot study, short≤10 mm ITI‐SLA implants were placed in the resorbed posterior maxilla by means of an osteotome sinus floor elevation (OSFE) procedure without grafting material. This paper presents 3‐year data assessing bone‐level changes around implants.Material and methods: Twenty‐five implants were placed in 17 patients to rehabilitate 16 molar and nine premolar sites. The mean residual bone height (RBH) was 5.4 ± 2.3 mm. A healing period of 3–4 months was allowed before abutment tightening. Most implants (21/25) were 10 mm long, and the others were 8 and 6 mm long. At the 3‐year control, endo‐sinus bone gain, implant length protruding into the sinus and crestal bone loss (CBL) were measured on periapical radiographs.Results: All implants fulfilled the survival criteria. Despite the absence of grafting material, implants were embedded into newly formed bone tissue. All implants gained endo‐sinus bone; the mean gained bone was 3.1 ± 1.5 mm. The residual protrusion length decreased from 4.9 ± 2.1 to 1.8 ± 2.1 mm. CBL was 0.9 ± 0.8 mm.Conclusions: This study confirms that the OSFE procedure without grafting material is sufficient to create bone beyond the natural limit of the sinus. On the mid‐term of 3 years, the technique was found to be predictable in the posterior maxilla when the RBH is limited. Implants gained endo‐sinus bone despite the lack of grafting material. Bone gain was still improving over the first‐year control. No shrinkage of the augmented area was observed.


    • 15 February 2008
      • Vol. 22  (6) , 1001-6

    Starch-induced implant periapical lesion: a case report.

    by Rabah Nedir, Mark Bischof, Ollivier Pujol, Raymond Houriet, Jacky Samson, Tommaso Lombardi

    This paper reports an implant periapical lesion (IPL) with a previously unreported etiology. The presence of an osteolytic area around the apex and around the middle portion of a stable Straumann hollow-screw implant was found on periapical radiographs 3.5 years after implant placement. Case management involved curettage of the soft tissue surrounding the implant apex as well as resection of the nonosseointegrated portion of the implant. Histopathologic examination revealed a connective fibrous tissue containing a dense chronic inflammatory infiltrate with a foreign-body material. Polarized light microscopy and Fourier transform infrared microspectroscopy identified the foreign-body material as starch particles. Etiology of this IPL was thus related to a foreign-body reaction to starch particles. This exogenous contamination probably originated from starch-coated gloves during the surgical procedure. This case report suggests that IPL may successfully be treated by debridement and implant resection instead of implant removal. Peri-implant apical soft tissue should be systematically submitted for histopathologic examination.


    • 28 December 2006
      • Vol. 21  (6) , 919-28

    Prosthetic complications with dental implants: from an up-to-8-year experience in private practice.

    by Rabah Nedir, Mark Bischof, Serge Szmukler-Moncler, Urs C Belser, Jacky Samson

    Evaluation of prosthetic complication was performed on 236 patients treated with 528 implants in an 8-year private practice experience. The study sample included 55 overdentures (ODs) and 265 fixed partial dentures (FPDs). Among the latter, 231 FPDs were cemented and 34 were screw-retained. The type and frequency of prosthetic incidents were recorded, including adjustments and complications. Statistical analysis was performed using a chi-square test to identify risk factors associated with complications. Over this period, 1 abut ment fractured and 2 became loose, leading to a cumulative implant component success rate of 99.2%. Patients with removable prostheses had more complications than those with fixed ones, 66.0% versus 11.5%; the difference was significant (P < .001). Posterior fixed prostheses had more complications than anterior ones, 11.0% versus 0%; however, the difference was not significant (P = .16). The complication rates for cemented and screw-retained prostheses did not differ significantly (10.4% versus 5.9%; P = .61). Prostheses with an extension cantilever had more complications, 29.4% versus 7.9%; the difference was significant (P = .01). In the OD group, the ball-retained prostheses had a significantly higher rate of complications than the bar-retained ones (77.5% versus 42.9%; P = .04). In the FPD group, complications were not recurrent; most occurred during the first 2 years, and the rate of complications did not increase with time. In the OD group, 1.3 incidents per prosthesis were recorded. Incidents were often recurrent, and the rate of complications did not decrease with time. Removable and fixed prostheses were associated with complications at different frequencies and of different types. In the removable group, adjustments and foreseeable complications were numerous, recurrent, and usually easy to manage. Bar-retained prostheses had fewer complications than ball-retained ones. In the fixed group, complications were limited in number and did not increase with time. Complications were restricted to the posterior region.


  • Osteotome sinus floor elevation without grafting material: a 1‐year prospective pilot study with ITI implants

    by Rabah Nedir, Mark Bischof, Lydia Vazquez, Serge Szmukler‐Moncler, Jean‐Pierre Bernard

    Objective: The aim of the present pilot study was to evaluate: (1) the predictability of an osteotome sinus floor elevation procedure with ITI‐SLA implants without placing a bone grafting material, and (2) the possibility to gain bone height without filling the created space with a bone grafting material.Material and methods: Seventeen patients received 25 implants protruding in the sinus. Most implants (21/25) were 10 mm long, eight were inserted in type 2 bone, 12 in type 3 and five in type 4 bone. At implant placement, the mean residual bone height (RBH) under the maxillary sinus was 5.4±2.3 mm; it was 5.7±2.6 mm on the mesial side and 5.1±1.9 mm on the distal side. Nineteen implants had less than 6 mm of bone on at least one side and six implants had less than 6 mm on both sides. A healing period of 3–4 months was allowed before abutment tightening at 35 Ncm. The percentage of stable implants at abutment tightening and at the 1‐year control was calculated. The endo‐sinus bone gain and the crestal bone loss (CBL) at the mesial and distal sides were measured.Results: Abutments were tightened after 3.1±0.4 months. All implants but one (96%) resisted the applied 35 Ncm torque. At the 1‐year control, all implants were clinically stable and supported the definitive prosthesis. All showed endo‐sinus bone gain; the mean gain was 2.5±1.2 mm. The mean CBL was 1.2±0.7 mm. Endo‐sinus bone gain and RBH showed a strong negative correlation (r=−0.78 on the mesial side and −0.80 on the distal side). A good correlation (r=0.73) was found between implant penetration in the sinus and endo‐sinus bone gain.Conclusion: Elevation of the sinus membrane alone without addition of bone grafting material can lead to bone formation beyond the original limits of the sinus floor. Despite a limited RBH at implant placement, a healing period of 3 months was sufficient to resist a torque of 35 N cm and to lead to a predictable implant function at the 1‐year control.