Albert van Den Berg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Albert van Den Berg has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Regina Luttge
BIOS/The Lab‐on‐a‐Chip Group, MESA+ Institute for Nanotechnology, University of Twente, Enschede, The Netherlands
3 shared publicationsElwin X. Vrouwe
BIOS/The Lab-on-a-Chip Group, MESA+ Institute for Nanotechnology, University of Twente, Enschede, The Netherlands
2 shared publicationsA. Naso
Physics of Fluids Group, Department of Applied Physics, University of Twente, P.O. Box 217, Enschede, The Netherlands
1 shared publicationAna Valero
BIOS, the Lab-on-a-chip Group, MESA+ Institute for Nanotechnology, University of Twente, PO Box 217, 7500 AE, Enschede, The Netherlands
1 shared publication- Ana Valero
Microsystems Laboratory, Batiment de Microtechnique Station 17, Swiss Federal Institute of Technology, CH-1015, Lausanne, Switzerland
1 shared publication C. Pirat
Physics of Fluids Group, Department of Applied Physics, University of Twente, P.O. Box 217, 7500 AE, Enschede, The Netherlands
1 shared publication
Latest Publications
- 17 April 2008
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 8 (6) , 945-949
Quantification of electrical field-induced flow reversal in a microchannel
We characterize the electroosmotic flow in a microchannel with field effect flow control. High resolution measurements of the flow velocity, performed by micro particle image velocimetry, evidence the flow reversal induced by a local modification of the surface charge due to the presence of the gate. The shape of the microchannel cross-section is accurately extracted from these measurements. Experimental velocity profiles show a quantitative agreement with numerical results accounting for this exact shape. Analytical predictions assuming a rectangular cross-section are found to give a reasonable estimate of the velocity far enough from the walls.
- 17 April 2008
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 8 (6) , 945-949
Quantification of electrical field-induced flow reversal in a microchannel
We characterize the electroosmotic flow in a microchannel with field effect flow control. High resolution measurements of the flow velocity, performed by micro particle image velocimetry, evidence the flow reversal induced by a local modification of the surface charge due to the presence of the gate. The shape of the microchannel cross-section is accurately extracted from these measurements. Experimental velocity profiles show a quantitative agreement with numerical results accounting for this exact shape. Analytical predictions assuming a rectangular cross-section are found to give a reasonable estimate of the velocity far enough from the walls.
- 26 November 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 8 (1) , 62-67
Gene transfer and protein dynamics in stem cells using single cell electroporation in a microfluidic device
There is great interest in genetic modification of bone marrow-derived mesenchymal stem cells (MSC), not only for research purposes but also for use in (autologous) patient-derived-patient-used transplantations. A major drawback of bulk methods for genetic modifications of (stem) cells, like bulk-electroporation, is its limited yield of DNA transfection (typically then 10%). This is even more limited when cells are present at very low numbers, as is the case for stem cells. Here we present an alternative technology to transfect cells with high efficiency (>75%), based on single cell electroporation in a microfluidic device. In a first experiment we show that we can successfully transport propidium iodide (PI) into single mouse myoblastic C2C12 cells. Subsequently, we show the use of this microfluidic device to perform successful electroporation of single mouse myoblastic C2C12 cells and single human MSC with vector DNA encoding a green fluorescent-erk1 fusion protein (EGFP-ERK1 (MAPK3)). Finally, we performed electroporation in combination with live imaging of protein expression and dynamics in response to extracellular stimuli, by fibroblast growth factor (FGF-2). We observed nuclear translocation of EGFP-ERK1 in both cell types within 15 min after FGF-2 stimulation. Due to the successful and promising results, we predict that microfluidic devices can be used for highly efficient small-scale ‘genetic modification’ of cells, and biological experimentation, offering possibilities to study cellular processes at the single cell level. Future applications might be small-scale production of cells for therapeutic application under controlled conditions.
- 26 November 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 8 (1) , 62-67
Gene transfer and protein dynamics in stem cells using single cell electroporation in a microfluidic device
There is great interest in genetic modification of bone marrow-derived mesenchymal stem cells (MSC), not only for research purposes but also for use in (autologous) patient-derived-patient-used transplantations. A major drawback of bulk methods for genetic modifications of (stem) cells, like bulk-electroporation, is its limited yield of DNA transfection (typically then 10%). This is even more limited when cells are present at very low numbers, as is the case for stem cells. Here we present an alternative technology to transfect cells with high efficiency (>75%), based on single cell electroporation in a microfluidic device. In a first experiment we show that we can successfully transport propidium iodide (PI) into single mouse myoblastic C2C12 cells. Subsequently, we show the use of this microfluidic device to perform successful electroporation of single mouse myoblastic C2C12 cells and single human MSC with vector DNA encoding a green fluorescent-erk1 fusion protein (EGFP-ERK1 (MAPK3)). Finally, we performed electroporation in combination with live imaging of protein expression and dynamics in response to extracellular stimuli, by fibroblast growth factor (FGF-2). We observed nuclear translocation of EGFP-ERK1 in both cell types within 15 min after FGF-2 stimulation. Due to the successful and promising results, we predict that microfluidic devices can be used for highly efficient small-scale ‘genetic modification’ of cells, and biological experimentation, offering possibilities to study cellular processes at the single cell level. Future applications might be small-scale production of cells for therapeutic application under controlled conditions.
- 14 September 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (12) , 1666-1672
Sonoporation of suspension cells with a single cavitation bubble in a microfluidic confinement
We report here the sonoporation of HL60 (human promyelocytic leukemia) suspension cells in a microfluidic confinement using a single laser-induced cavitation bubble. Cavitation bubbles can induce membrane poration of cells located in their close vicinity. Membrane integrity of suspension cells placed in a microfluidic chamber is probed through either the calcein release out of calcein-loaded cells or the uptake of trypan blue. Cells that are located farther away than four times Rmax (maximum bubble radius) from the cavitation bubble center remain fully unaffected, while cells closer than 0.75 Rmax become porated with a probability of >75%. These results enable us to define a distance of 0.75 Rmax as a critical interaction distance of the cavitation bubble with HL60 suspension cells. These experiments suggest that flow-induced poration of suspension cells is applicable in lab-on-a-chip systems, and this might be an interesting alternative to electroporation.
- 14 September 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (12) , 1666-1672
Sonoporation of suspension cells with a single cavitation bubble in a microfluidic confinement
We report here the sonoporation of HL60 (human promyelocytic leukemia) suspension cells in a microfluidic confinement using a single laser-induced cavitation bubble. Cavitation bubbles can induce membrane poration of cells located in their close vicinity. Membrane integrity of suspension cells placed in a microfluidic chamber is probed through either the calcein release out of calcein-loaded cells or the uptake of trypan blue. Cells that are located farther away than four times Rmax (maximum bubble radius) from the cavitation bubble center remain fully unaffected, while cells closer than 0.75 Rmax become porated with a probability of >75%. These results enable us to define a distance of 0.75 Rmax as a critical interaction distance of the cavitation bubble with HL60 suspension cells. These experiments suggest that flow-induced poration of suspension cells is applicable in lab-on-a-chip systems, and this might be an interesting alternative to electroporation.
- 14 September 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (10) , 1266-1273
Labs-on-a-Chip: origin, highlights and future perspectives : On the occasion of the 10th μTAS conference
A graphical abstract is available for this content
- 14 September 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (10) , 1266-1273
Labs-on-a-Chip: origin, highlights and future perspectives : On the occasion of the 10th μTAS conference
A graphical abstract is available for this content
- 1 August 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (15) , 3032-3042
Microchip analysis of lithium in blood using moving boundary electrophoresis and zone electrophoresis
The determination of inorganic cations in blood plasma is demonstrated using a combination of moving boundary electrophoresis (MBE) and zone electrophoresis. The sample loading performed under MBE conditions is studied with the focus on the quantitative analysis of lithium. A concentration adjustment takes place when the sample components migrate into the chip during the sample loading step. Using a heart‐cutting method, a diluted sample plug is subsequently separated with capillary zone electrophoresis. The excessive dispersion that is typical of the samples with a high ionic strength is thereby prevented. The method can be easily applied to commercially available capillary electrophoresis microchips under the condition that the electroosmotic flow is suppressed. For the first time the lithium concentration is determined in the blood plasma from a patient on lithium therapy without sample pretreatment. Using a microchip with conductivity detection, a detection limit of 0.1 mmol/L is obtained for lithium in a 140 mmol/L sodium matrix.
- 1 August 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (15) , 3032-3042
Microchip analysis of lithium in blood using moving boundary electrophoresis and zone electrophoresis
The determination of inorganic cations in blood plasma is demonstrated using a combination of moving boundary electrophoresis (MBE) and zone electrophoresis. The sample loading performed under MBE conditions is studied with the focus on the quantitative analysis of lithium. A concentration adjustment takes place when the sample components migrate into the chip during the sample loading step. Using a heart‐cutting method, a diluted sample plug is subsequently separated with capillary zone electrophoresis. The excessive dispersion that is typical of the samples with a high ionic strength is thereby prevented. The method can be easily applied to commercially available capillary electrophoresis microchips under the condition that the electroosmotic flow is suppressed. For the first time the lithium concentration is determined in the blood plasma from a patient on lithium therapy without sample pretreatment. Using a microchip with conductivity detection, a detection limit of 0.1 mmol/L is obtained for lithium in a 140 mmol/L sodium matrix.
- 6 December 2004
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 5 (1) , 49-55
Apoptotic cell death dynamics of HL60 cells studied using a microfluidic cell trap device
This paper presents the design, fabrication and first results of a microfluidic cell trap device for analysis of apoptosis. The microfluidic silicon-glass chip enables the immobilization of cells and real-time monitoring of the apoptotic process. Induction of apoptosis, either electric field mediated or chemically induced with tumour necrosis factor (TNF-α), in combination with cycloheximide (CHX), was addressed. Exposure of cells to the appropriate fluorescent dyes, FLICA and PI, allows one to discriminate between viable, apoptotic and necrotic cells. The results showed that the onset of apoptosis and the transitions during the course of the cell death cascade were followed in chemically induced apoptotic HL60 cells. For the case of electric field mediated cell death, the distinction between apoptotic and necrotic stage was not clear. This paper presents the first results to analyse programmed cell death dynamics using this apoptosis chip and a first step towards an integrated apoptosis chip for high-throughput drug screening on a single cellular level.
- 6 December 2004
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 5 (1) , 49-55
Apoptotic cell death dynamics of HL60 cells studied using a microfluidic cell trap device
This paper presents the design, fabrication and first results of a microfluidic cell trap device for analysis of apoptosis. The microfluidic silicon-glass chip enables the immobilization of cells and real-time monitoring of the apoptotic process. Induction of apoptosis, either electric field mediated or chemically induced with tumour necrosis factor (TNF-α), in combination with cycloheximide (CHX), was addressed. Exposure of cells to the appropriate fluorescent dyes, FLICA and PI, allows one to discriminate between viable, apoptotic and necrotic cells. The results showed that the onset of apoptosis and the transitions during the course of the cell death cascade were followed in chemically induced apoptotic HL60 cells. For the case of electric field mediated cell death, the distinction between apoptotic and necrotic stage was not clear. This paper presents the first results to analyse programmed cell death dynamics using this apoptosis chip and a first step towards an integrated apoptosis chip for high-throughput drug screening on a single cellular level.
- 2 June 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (10-11) , 1660-1667
Direct measurement of lithium in whole blood using microchip capillary electrophoresis with integrated conductivity detection
The direct measurement of lithium in whole blood is described. Using microchip capillary electrophoresis (CE) with defined sample loading and applying the principles of column coupling, alkali metals were determined in a drop of whole blood. Blood collected from a finger stick was mixed with anticoagulant and transferred onto the chip without extraction or removal of components. The electrokinetic transport of red blood cells inside the channels was studied to find sample loading conditions suitable for the analysis of lithium without injecting cells into the separation channel. Both bare glass chips and chips coated with polyacrylamide were used showing the behavior of the cells under different electroosmotic flow conditions. In serum a detection limit for lithium of 0.4 mmol/L was reached. Proteins quickly contaminated untreated chip surfaces but devices with coating gave reproducible electropherograms. In addition, potassium and sodium were also detected in the same separation run. To our knowledge, this is the first device to directly measure ions in whole blood with the use of capillary zone electrophoresis on a microchip.
- 2 June 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (10-11) , 1660-1667
Direct measurement of lithium in whole blood using microchip capillary electrophoresis with integrated conductivity detection
The direct measurement of lithium in whole blood is described. Using microchip capillary electrophoresis (CE) with defined sample loading and applying the principles of column coupling, alkali metals were determined in a drop of whole blood. Blood collected from a finger stick was mixed with anticoagulant and transferred onto the chip without extraction or removal of components. The electrokinetic transport of red blood cells inside the channels was studied to find sample loading conditions suitable for the analysis of lithium without injecting cells into the separation channel. Both bare glass chips and chips coated with polyacrylamide were used showing the behavior of the cells under different electroosmotic flow conditions. In serum a detection limit for lithium of 0.4 mmol/L was reached. Proteins quickly contaminated untreated chip surfaces but devices with coating gave reproducible electropherograms. In addition, potassium and sodium were also detected in the same separation run. To our knowledge, this is the first device to directly measure ions in whole blood with the use of capillary zone electrophoresis on a microchip.