Dejan Zontar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dejan Zontar has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
D. Kuhelj
Clinical Radiology Institute, University Medical Center Ljubljana , Ljubljana , Slovenia
1 shared publicationD. Skrk
Slovenian Radiation Protection Administration , Ljubljana , Slovenia
1 shared publicationDamijan Skrk
Slovenian Radiation Protection Administration, Ljubljana, Slovenia
1 shared publicationDean Pekarovic
Clinical Radiology Institute, University Medical Center Ljubljana, Ljubljana, Slovenia
1 shared publicationDimitrij Kuhelj
Clinical Radiology Institute, University Medical Center Ljubljana, Ljubljana, Slovenia
1 shared publicationU. Zdesar
Institute of Occupational Safety , Ljubljana , Slovenia
1 shared publication
Latest Publications
- Open Access
- 1 March 2015
- Published by Walter de Gruyter GmbH in Radiology and Oncology
- Vol. 49 (1) , 99-106
Estimated collective effective dose to the population from radiological examinations in Slovenia
Background. The aim of the study was to systematically evaluate population exposure from diagnostic and interventional radiological procedures in Slovenia. Methods. The study was conducted in scope of the “Dose Datamed 2” project. A standard methodology based on 20 selected radiological procedures was adopted. Frequencies of the procedures were determined via questionnaires that were sent to all providers of radiological procedures while data about patient exposure per procedure were collected from existing databases. Collective effective dose to the population and effective dose per capita were estimated from the collected data (DLP for CT, MGD for mammography and DAP for other procedures) using dose conversion factors. Results. The total collective effective dose to the population from radiological in 2011 was estimated to 1300 manSv and an effective dose per capita to 0.6 mSv of which approximately 2/3 are due to CT procedures. Conclusions. The first systematic study of population exposure to ionising radiation from radiological procedures in Slovenia was performed. The results show that the exposure in Slovenia is under the European average. It confirmed large contributions of computed tomography and interventional procedures, identifying them as the areas that deserve special attention when it comes to justification and optimisation.
- 1 March 2015
- Published by Walter de Gruyter GmbH in Radiology and Oncology
- Vol. 49 (1) , 99-106
Open AccessEstimated collective effective dose to the population from radiological examinations in Slovenia
Background. The aim of the study was to systematically evaluate population exposure from diagnostic and interventional radiological procedures in Slovenia. Methods. The study was conducted in scope of the “Dose Datamed 2” project. A standard methodology based on 20 selected radiological procedures was adopted. Frequencies of the procedures were determined via questionnaires that were sent to all providers of radiological procedures while data about patient exposure per procedure were collected from existing databases. Collective effective dose to the population and effective dose per capita were estimated from the collected data (DLP for CT, MGD for mammography and DAP for other procedures) using dose conversion factors. Results. The total collective effective dose to the population from radiological in 2011 was estimated to 1300 manSv and an effective dose per capita to 0.6 mSv of which approximately 2/3 are due to CT procedures. Conclusions. The first systematic study of population exposure to ionising radiation from radiological procedures in Slovenia was performed. The results show that the exposure in Slovenia is under the European average. It confirmed large contributions of computed tomography and interventional procedures, identifying them as the areas that deserve special attention when it comes to justification and optimisation.
- 5 February 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 139 (1-3) , 262-265
Patient peak skin doses from cardiac interventional procedures
Interventional cardiac procedures not only lead to significant effective doses for the patient but also can potentially cause deterministic effects on the patient's skin. Information about the peak (maximal) skin doses (PSD) received by patients during percutaneous transluminal coronary angioplasty procedures were collected from three cardiac catheter rooms. Cumulative dose at the interventional reference point (CDIRP) was collected for 161 patients and for 16 patients PSD was determined using Gafchromic dosimetry films. The comparison showed that CDIRP readings give a useful but conservative estimation of patient peak skin dose as it can lead to a significant overestimation. The median and third quartile values of CDIRP were 0.64 and 0.92 Gy, respectively. The 2 Gy threshold for deterministic effects was exceeded in nine patients. A good correlation was found between CDIRP and kerma area product measurements while the correlation with fluorography time was very weak.
- 5 February 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 139 (1-3) , 262-265
Patient peak skin doses from cardiac interventional procedures
Interventional cardiac procedures not only lead to significant effective doses for the patient but also can potentially cause deterministic effects on the patient's skin. Information about the peak (maximal) skin doses (PSD) received by patients during percutaneous transluminal coronary angioplasty procedures were collected from three cardiac catheter rooms. Cumulative dose at the interventional reference point (CDIRP) was collected for 161 patients and for 16 patients PSD was determined using Gafchromic dosimetry films. The comparison showed that CDIRP readings give a useful but conservative estimation of patient peak skin dose as it can lead to a significant overestimation. The median and third quartile values of CDIRP were 0.64 and 0.92 Gy, respectively. The 2 Gy threshold for deterministic effects was exceeded in nine patients. A good correlation was found between CDIRP and kerma area product measurements while the correlation with fluorography time was very weak.